SOLICITATION NOTICE
45 -- Variable Speed Drive Pressure Control System
- Notice Date
- 3/12/2008
- Notice Type
- Solicitation Notice
- NAICS
- 423720
— Plumbing and Heating Equipment and Supplies (Hydronics) Merchant Wholesalers
- Contracting Office
- Department of Agriculture, Agricultural Research Service, South Atlantic Area Office/Athens, GA, 950 College Station Rd., Athens, GA, 30605, UNITED STATES
- ZIP Code
- 00000
- Solicitation Number
- RFQ011438408
- Response Due
- 4/1/2008
- Archive Date
- 4/16/2008
- Point of Contact
- Elaine Wood, Contract Specialist, Phone 706-546-3534, Fax 706-546-3444
- E-Mail Address
-
elaine.wood@ars.usda.gov
- Small Business Set-Aside
- Total Small Business
- Description
- This is a combined synopsis/solicitation for a commercial item prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested and a written solicitation will not be issued. The solicitation number RFQ-011-4384-08 is issued as a request for quotations and incorporates provisions and clauses that are in effect through FAC 2005-24. This procurement is a total small business set-aside. The NAICS code applicable to this acquisition is 423720. For a company to qualify as a small business, the small business size standard is 100 employees. USDA, ARS has a requirement for one variable speed drive pressure control system. Supplier is to provide a complete fully automatic pressure control system that tracks actual system pressure. At a minimum, the system shall meet the following performance requirements: 480/3/60 single point power connection with disconnect, 304 stainless steel header piping, high efficiency motors with 15 H variable speed drives, three pump system - 525 GPM total, 175 GPM per pump, 40 PSI Boost, 20 PSI Inlet pressure, 92? TDH, maximum package size 72?W x 48?D x 72?H. This should be a complete skid mounted package: fully assembled, piped, wired and tested. Pump structural steel base shall incorporate rubber-in-shear vibration isolators. Package system shall be Underwriter Laboratory (UL) listed. The controller shall be UL 508 approved. Centrifugal pumps should be close coupled. System piping shall be of 304 stainless steel pipe with double ended flanged connection for flow in either direction. Pump design and package layout must allow pump service without disconnecting piping. It must incorporate a three valve bypass. Pumps are to be constructed of ductile iron with 316 impellers and trim with 200 psi working pressure. System must have manual constant speed by-pass, variable speed drive for each pump, isolation valves on each pump, PRV on each pump, programmable pump controller with panel mounted user interface, user selectable manual or automatic alternation, high temperature pump protection, low suction pressure shutdown, high system pressure alarm, local alarm indication, remote alarm contacts, single sphere flexible connectors, door mounted PLC Controller interface and liquid filled Severe Duty S/S pump pressure gauges.
- Place of Performance
- Address: USDA ARS SAA, 2001 South Rock Rd, Ft Pierce, FL
- Zip Code: 34945
- Country: UNITED STATES
- Zip Code: 34945
- Record
- SN01530411-W 20080314/080312223407 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |