SOLICITATION NOTICE
N -- SECURITY SYSTEM INSTALLATION
- Notice Date
- 3/21/2008
- Notice Type
- Solicitation Notice
- Contracting Office
- M20001 COMMANDER U.S. MARINE CORPS FORCES COMMAND CONTRACTING 1775 FORRESTAL DRIVE Norfolk, VA
- ZIP Code
- 00000
- Solicitation Number
- M2000108Q0001
- Response Due
- 4/18/2008
- Archive Date
- 5/18/2008
- Point of Contact
- ALICE RODRIGUEZ 757-445-4331 GySgt Donald J. Jones 757-445-1524
- E-Mail Address
-
Email your questions to alice.rodriguez@usmc.mil
(alice.rodriguez@usmc.mil)
- Description
- PERFORMANCE WORK STATEMENT (PWS) TEMPLATE The contractors shall provide all parts and labor acquired for the installation of a LENEL Security System for the MCTAG located at Fort Story, Virginia Beach, VA in accordance with specifications stated below. a. Directions to the contractor to perform work tasks. Each building (937, 938, and 939) will have: 1. Break glass installed on all windows. 2. Balanced Magnetic Strips (BMS) will be installed on all doors. 3. Door hinges must be reinstalled so they are on the inside. 4. All cipher locks will be removed and LENEL Card Readers will be installed on all doors providing access to buildings and rooms. The LENEL Card Readers must CAC -enabled to read the CAC magnetic strip. 5. Each building will have one emergency exit door with a BMS and PANIC hardware. 6. A-1 Telephones will be installed at Buildings 937 and 938 7. Public Works will need to re-core all doors. 8. All doors will need repaired due to inoperability (for proper Closure). 9. The Communications room and each SIPRNET Connectivity areas will have individual access and control Panel and will be on individual partition for annunciation. (Limited Access to the area) 10. The EKMS Vault will have an individual access/control Panel and Individually Partition for annunciation (Limited Access to the area). 11. Motion Sensors installed in all Secure Areas. b. Specification of data requirements. As outlined in the following paragraphs. c. Description of deliverable products. 1) Dataline shall provide all labor and materials necessary to: a) Install one Lenel 32ES Security System Server in Bldg 937 on Fort Story Army Base. b) Install one Lenel Client Badging Station in Bldg 937 on Fort Story Army Base. c) Install Card Reader, BMS, Request to Exit IR, Emergency Request to Exit Push Button, and Magnetic lock on Bldg 937 doors: i) Front Entrance (Double doors- two maglocks) ii) Instructor?s Lounge rear door d) Install Card Reader, BMS, Request to Exit IR, Electric Door Strike on Bldg 937 doors: i) VTC room interior entrance ii) VTC room exterior entrance iii) Network/Storage closet iv) Deputy Director?s Office v) Director?s Office vi) Enlisted Advisor?s Office e) Install Passive Infrared Sensors (PIR?s) in, Bldg 937, rooms with windows. f) Install Passive Infrared Sensor (PIR) in, Bldg 937, room in Network/Storage closet. g) Install Glass Break Sensors in all rooms, in Bldg 937, with windows to cover each window. h) Install BMS on Bldg 937 Emergency Exit door with Audible alarms when opened. i) Install AI-Phone Camera at Front entrance of Bldg 937. j) Install AI-Phone Master Station with door release capability in Lobby of Bldg 937. k) Install Secure Access Keypad inside Bldg 938 Network/Storage Closet programmed to secure PIR sensor in Network/Storage Closet. l) Install Secure Access Keypad inside Bldg 938 Front Entrance programmed to secure all PIR sensors throughout the building. m) Install Card Reader, BMS, Request to Exit IR, Emergency Request to Exit Push Button, and Magnetic lock on Bldg 938 doors: i) Front Entrance (Double doors- two maglocks) ii) East Wing door iii) West Wing door iv) East Wing exterior door n) Install Glass Break Sensors in all rooms, in Bldg 938, with windows to cover each window. o) Install Passive Infrared Sensors (PIR?s) in, Bldg 938, rooms with windows. p) Install BMS on Bldg 938 Emergency Exit door with Audible alarms when opened. q) Install AI-Phone Master Station with door release capability in Lobby of Bldg 938 to release Bldg 937 Main Entrance. r) Install Card Reader, BMS, Request to Exit IR, Emergency Request to Exit Push Button, and Magnetic lock on Bldg 939 doors: i) G6 Main Entrance ii) Main Comm Locker Boat Entrance (Double doors- two maglocks) iii) Boat House (Double doors- two maglocks) s) Install Card Reader, BMS, Request to Exit IR, Electric Door Strike on Bldg 937 doors: i) Sipernet Server Room ii) Office Space 1 iii) Office Space 2 t) Install BMS on Bldg 939 Emergency Exit door with Audible alarms when opened. u) Install Passive Infrared Sensor (PIR) in, Bldg 939, room in Sipernet Server Room. v) Install Secure Access Keypad inside Bldg 939 G6 Main Entrance programmed to secure the G6 space. w) Install Secure Access Keypad inside Bldg 939 Sipernet Server Room programmed to secure PIR sensor in Server Room. x) Install Personnel Turnstile with card reader along the fence line leading to the parking lot. FAR PART 12.6 52.222-41, Service Contract Act of 1965(NOV 2007)(41 U.S.C. 351, et seq) 52.225-1, Buy American Act--Supplies (JUNE 2003)(41 U.S.C. 10a-10d). 52.232-33, Payment by Electronic Funds Transfer--Central Contractor Registration(OCT 2003)(31 U.S.C. 3332). NAICS CODE: 561621
- Record
- SN01538931-W 20080323/080321224834 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |