SOLICITATION NOTICE
63 -- Installation of High Security Locks, Intrusion Detection System, Electronic Access Control, and CCTV System in Jamaica, NY
- Notice Date
- 4/1/2008
- Notice Type
- Solicitation Notice
- Contracting Office
- Office of Acquisitions - TSA 25, Arlington, VA 22202
- ZIP Code
- 22182
- Solicitation Number
- HSTS01-08-P-RES374
- Response Due
- 4/16/2008
- Archive Date
- 10/13/2008
- Point of Contact
- Rebecca D Leake, Phone 571-227-1589
- E-Mail Address
-
Rebecca.Leake@dhs.gov
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, in conjunction with FAR 13.5, as applicable, and as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; bids are being requested and a written solicitation will not be issued. The solicitation number is HSTS01-08-P-RES374 and is issued as an invitation for bids (IFB), unless otherwise indicated herein. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2005-20. The associated North American Industrial Classification System (NAICS) code for this procurement is 334290 with a small business size standard of 750 employees. This requirement is a [ Small Business ] set-aside and only qualified offerors may submit bids. The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2008-04-16 14:00:00.0 Eastern Time or as otherwise displayed at www.FedBid.com. FOB Destination shall be Multiple shipping information. The DHS-Transportation Security Administration requires the following items, Brand Name or Equal, to the following: LI 001, The Transportation Security Administration, Office of Security, has a requirement for the installation of High Security Locks, Intrusion Detection System, Electronic Access Control, and CCTV System. Please see attached Scope of Work, Diagram, and Clauses., 1, LOT; LI 002, Door Hardware: Mortise High Security Lockset with Deadbolt – Storeroom Function, MARKS Part Number 5-CP-92-FS/32D-G3 with Medeco UL 437 M-3 Interchangeable Core cylinder. (Doors 1,2,3,4). The contractor is responsible for obtaining, correctly installing, and maintaining all door hardware. The MARKS Store Room Function Mortise Lockset with Deadbolt must have the latchbolt retracted by key outside or by lever inside. Outside lever is always fixed. The deadbolt can only be thrown or retracted by key outside or thumb-turn inside. By turning the inside lever, it simultaneously retracts both deadbolt and latchbolt. The auxiliary latch deadlocks latchbolt when door is closed. This Lockset must accept a Medeco #32-0200 housing and interchangeable core.1, 1, LOT; LI 003, Door Hardware:Cylindrical Lever Lockset – Store Room Function, MARKS Part Number 195-RF/26D-F21with Medeco UL 437 M-3 Interchangeable Core cylinder over-ride. (LAN Room/ Secure Storage Room)The contractor is responsible for obtaining, correctly installing, and maintaining all door hardware. The Store Room Function Lockset will function so that the latchbolt is retracted by key outside or by lever inside. Outside knob/lever always inoperative. The auxiliary latch deadlocks latchbolt when door is closed. This Lockset must accept a Medeco UL 437 M-3 Interchangeable Core cylinder for secure key access., 1, LOT; LI 004, Door Hardware:Medeco UL 437 M-3 Interchangeable Core cylinder The Contractor is responsible for purchasing a high security Medeco lock and key system approved by the TSA. In procuring the lock and key system, the Contractor must adhere to the following requirements: 1) The key operated lock housing must accept a Medeco UL 437 M-3 Interchangeable Core.2) The client’s identity (TSA) and the address where the locks will be installed will not be divulged except as agreed upon by TSA.3) All change keys and core keys will be delivered to TSA field representative.4) All change keys will be impressed with a sequential serial number on the bow of each key.5) The core key will be impressed with “Core” or “Control” on the bow of the key. All pinning and key cut information will be provided to a TSA representative.6) Each core will be labeled with a change number on the side and a serial number on the opposite side of the cylinder. These numbers should appear on the sides of the top chamber area.7) The Contractor or Lessor will provide and install all locksets, cores and keys. Each key will have the serial number stamped on one side of the bow. All keys and any remaining cores will be given to the TSA representative. The Contractor will be responsible for creating and maintaining an expandable multi tiered master key system hierarchy. The hierarchy will be designed by the contractor based on the needs and requests of the local/field TSA Field Office. The contractor will provide and install/replace a Heavy Duty door closer on each Perimeter/Alarmed Door. NOTE: THIS NOTICE MAY HAVE POSTED ON FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (01-APR-2008). IT ACTUALLY APPEARED OR REAPPEARED ON THE FEDBIZOPPS SYSTEM ON 02-APR-2008, BUT REAPPEARED IN THE FTP FEED FOR THIS POSTING DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/DHS/TSA/HQTSA/HSTS01-08-P-RES374/listing.html)
- Place of Performance
- Address: Multiple shipping information.
- Zip Code: Multiple
- Country: Multiple
- Zip Code: Multiple
- Record
- SN01546357-F 20080404/080403042700 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |