SOLICITATION NOTICE
Y -- Computer Room Expansion on 6th Floor, D Wing
- Notice Date
- 4/4/2008
- Notice Type
- Presolicitation
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- Department of Veterans Affairs;Samuel S . Stratton VA Medical Center;113 Holland Avenue;Albany NY 12208-3410
- ZIP Code
- 12208-3410
- Solicitation Number
- VA-528-08-RP-0079
- Response Due
- 5/1/2008 5:00:00 PM
- Archive Date
- 4/13/2008
- Point of Contact
- Kellyann BrunoContract Specialist
- Description
- Renovate Computer Room D611, Project Number 528A8-06-818, Located at the Stratton VA Medical Center Albany, NY 12208. The existing Computer Center consists of the Main Computer Room, an office/work area, a Mechanical Room, and a Utility/Storage Room. These areas are to be incorporated into the Main Computer Room thereby expanding this space. Additionally, an adjacent Storage Room is to be annexed into the Computer Center and converted into an office. The mechanical and electrical systems are to be modified and upgraded. The Computer Center is not connected to the emergency electrical power generator system and is also part of this project. The work is to be performed in 2 phases and includes, but not limited to, the following:"Asbestos removal - ACM Flooring, pipe/fitting insulation, aircell insulation panels."Remove air handling unit from Mechanical Room."Remove electrical in rear Utility/Storage Room."Install outdoor fan coil units (5 ea.), electrical power, etc. and perform modifications to the existing 4th floor roof system as necessary."Install glycol pipe from the 4th floor roof to the 6th floor Computer Center."Install an airtight construction barrier between the phase areas, from the concrete floor to the underside of the deck."Perform selective architectural, mechanical/HVAC and electrical demolition."Install raised access floor system."Construct new 2-hour fire-rated column enclosures, and pipe chases, cut-out and install new door and ramp, tie-in new components with the existing finishes, mechanical/hvac systems, electrical system, fire alarm system, security system, etc."Install additional air conditioning units."Install Uninterrupted Power Supply units and all associated equipment in Computer Center."Provide new electrical power supply system from Generator to the Main Core Sub-Basement Area via the Utility and C Wings."Provide electrical power to the 4th floor roof hvac equipment from the sub-basement area."Connect the Computer Center electrical system to eht emergency generator electrical system.Estimated construction cost range is between $1,000,000.00 to $2,000,000.00. Award will be made on a competitive Full and Open Competition (there are no set a-sides for this project.) basis to the responsible business responding to this solicitation that provides the best value in accordance with the solicitation requirements, provided that (a) the award can be made at a fair and reasonable price, and (b) the award can be made to a responsible offeror eligible to receive the award under this criteria. Offers will be evaluated on the basis of proposed construction management, proposed team, past experience and past performance as well as price. Technical factors, when combined, will be considered to be slightly more important than price.OBTAINING SOLICITATION MATERIAL: Solicitation materials consisting of the Request for Proposal Details, Specifications, Drawings, and Contract Forms for submitting a response are available from VA by viewing them on-line following these instructions: go to www.goDataflow.com click the "Order Plans" button, click the project link (ex: <insert Project name here>), under "New User" click the "Register Now" button to obtain a valid user name and password. Questions concerning where to find information or how to navigate the Dataflow web site, should be directed to Dataflow Inc. to Melissa Plantz at (518) 463-2192 or call toll free at (866) 829-2821 and ask for Annie Cicciarelli,. Paper copies of Bidding Documents may be purchased by ordering them on the Dataflow website or by calling Dataflow at (518) 463-2192. These documents will not be posted on FedBizOpps. All Interested parties (subs & primes) should register at http://www.fedbizopps.gov as an "Interested Vendor" so that others will know of your interest in participating in this procurement. A Bidder's mailing list WILL NOT be prepared nor distributed by the Contracting Officer.SOLICITATION AMENDMENTS: Amendments to the solicitation will be posted at http://www.fedbizopps.gov. Paper copies of the amendments will NOT be individually mailed. By registering to "Receive Notification", you will be notified by e-mail of any new amendments that have been issued and posted. Data Flow will also e-mail registered vendors notification of amendments. Offerors are reminded that they are responsible for obtaining and acknowledging all amendments to this solicitation prior to the time for receipt of offers as prescribed by FAR 52.215-1 Instructions to Offerors - Competitive Acquisition.Request for Information (RFI): Any questions must be submitted in a Request for Information format (RFI). It must be on Company letterhead, have the solicitation number, project name in the subject field and a signature. RFI may be submitted via e-mail to Kellyann.bruno@va.gov. Please all 48 hours for a response, no phone calls please. The RFI must be in a question format and specify the specification or drawing section in question. This information will speed up the response time.
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=92ddb58e3be3def8290e9dc14e6a9642&tab=core&_cview=1)
- Record
- SN01548134-W 20080406/080404221910-92ddb58e3be3def8290e9dc14e6a9642 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |