SOLICITATION NOTICE
Y -- Folsom Transformer K1A and K2A Replacement
- Notice Date
- 6/23/2008
- Notice Type
- Presolicitation
- Contracting Office
- Bureau of Reclamation - Mid-Pacific Regional Office 2800 Cottage Way, Rm. E-1815 Sacramento CA 95825
- ZIP Code
- 95825
- Solicitation Number
- 08SP200135A
- Response Due
- 8/7/2008
- Archive Date
- 6/23/2009
- Point of Contact
- Don Neal Contract Specialist 9169785144 dneal@mp.usbr.gov;
- Small Business Set-Aside
- N/A
- Description
- The Bureau of Reclamation intends to issue a Request for Proposals for a firm fixed-price construction contract for Folsom Transformer K1A and K2A Replacement. More specific requirements are listed below. The will be performed at the Folsom Dam, which is located in the City of Folsom, Sacramento County, California. The NAICS Code is: 811310 and the related small business size standard is $6.5 million. This procurement is full and open and not set-aside. Solicitation 08SP200135A will be posted to on or about July 7, 2008. The date for receipt of proposals will be approximately August 7, 2008. The solicitation must be downloaded at the above website; Except for drawings, no paper copy of this solicitation will be distributed. Offerors wishing to acquire the drawings must register on the bidder's list at http://ideasec.nbc.gov. The drawings, specifications, and bidder's list will only be available once the solicitation posted. The estimated amount of this acquisition is between $1,000,000 and $5,000,000 Prospective contractors MUST be actively registered in the Central Contractor Registration (CCR) database at http://www.ccr.gov to be eligible for award. Questions concerning this solicitation should be directed to Don Neal by email at dneal@mp.usbr.gov. ____________________________________________The principal components of the work to be performed include: A. Furnish and install one three-phase, 2-winding, 230-kV power transformer and appurtenances.B. Furnish and install one three-phase, 2-winding 115-kV power transformer and appurtenances.C. Remove, temporarily store onsite, and dispose offsite one three-phase, 230-kV power transformer.D. Remove, temporarily store onsite, and dispose offsite one three-phase 115-kV power transformer.E. Existing transformers to be removed are coated with paint containing lead and other heavy metals.F. Remove and dispose of three surge arresters and appurtenances.G. Handling and disposing of PCB contaminated oil and equipment.H. Modifying cooling water piping.I. Work is located at Folsom Powerplant on the American River approximately 2 miles north of Folsom, California in Sacramento County.
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=8f4202aeaa5926a2646f839213c63f0c&tab=core&_cview=1)
- Place of Performance
- Address: Folsom CA
- Zip Code: 956301799
- Zip Code: 956301799
- Record
- SN01599142-W 20080625/080623220050-8f4202aeaa5926a2646f839213c63f0c (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |