SOURCES SOUGHT
66 -- Carbon Monoxide Trace Level Enhanced Analyzer
- Notice Date
- 8/11/2008
- Notice Type
- Sources Sought
- NAICS
- 423490
— Other Professional Equipment and Supplies Merchant Wholesalers
- Contracting Office
- Environmental Protection Agency, Office of Research and Development, NHEERL/AED Narragansett, 27 Tarzwell Drive, Narragansett, Rhode Island, 02882
- ZIP Code
- 02882
- Solicitation Number
- (003)
- Response Due
- 8/22/2008
- Archive Date
- 9/6/2008
- Point of Contact
- Glennis Reslock,, Phone: 401-782-3056
- E-Mail Address
-
reslock.glennis@epa.gov
- Small Business Set-Aside
- N/A
- Description
- The US Environmental Protection Agency, New England Research Laboratory, Region 1, North Chelmsford, MA is seeking qualified sources to procure a Carbon Monoxide Trace Level Enhanced Analyzer that must meet the following: Salient Characteristics: All program requirements must be met. Space/Size/Weight requirements: 1. Size: between 16 & 17 inches wide, between 8 & 9 inches high, between 22 & 23 inches in length and is rack mountable in a standard 19 inch rack. 2. The weight of this unit needs to be between 50 & 60 pounds. 3. The Zero/Span valves w/zero air scrubber assembly must be installed internally. 4. Span drift for no more the +/- 1% of full scale. Technical Specifications: 1. The instrument sample range must include 0-1ppm, 0-5ppm, 0-10ppm, 0-20ppm, 0-50ppm, 0-100ppm and 0-1000ppm with EPA Equivalence. 2. The sample flow rate of 0.0 to 0.5 LPM and can not exceed 0.5 LPM. 3. 120 Volts, 50/60 Hz, with standard plug. 4. A Zero and Span Valve assemble is required. This assembly consists of valve(s) that allow Reference Zero sample gas and/or Span calibration gas into the instrument. 5. A zero air scrubber that cleans the air prior to the zero/span valve is required. Any firm who sells the type of system as stated herein, is encouraged to respond. All questions should be directed to Glennis Reslock via email at reslock.glennis@epa.gov No telephonic or faxed requests will be honored.
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=dc1127d79eddb305655926d4baa5ed88&tab=core&_cview=1)
- Place of Performance
- Address: USEPA/New England Research Laboratory, Region 1, 11 Technology Drive, North Chelmsford, Massachusetts, 01863, United States
- Zip Code: 01863
- Zip Code: 01863
- Record
- SN01636197-W 20080813/080811222530-dc1127d79eddb305655926d4baa5ed88 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |