J -- Emergency Generator Maintenance and Repair

Notice Date
8/15/2008
 
Notice Type
Presolicitation
 
NAICS
811219 — Other Electronic and Precision Equipment Repair and Maintenance
 
Contracting Office
Department of Veterans Affairs, VA Tennessee Valley Health Care System (Murfreesboro), Department of Veterans Affairs Tennessee Valley Health Care System Alvin C. York Campus, Department of Veterans Affairs;ASC - VISN 9;3400 Lebanon Pike;Murfreesboro TN 37129
 
ZIP Code
37129
 
Solicitation Number
VA-249-08-RQ-0268
 
Response Due
8/20/2008
 
Archive Date
9/19/2008
 
Point of Contact
Donald LarsonContracting Officer<br />
 
Small Business Set-Aside
N/A
 
Description
The following Veteran Administration Medical Center (VAMC) located at 1030 Jefferson Avenue Memphis, TN will be providing a solicitation for Preventative Maintenance on Emergency Generators, NAICS code 811219. Services to be provided shall include Contractor to furnish all parts, materials, tools, equipment, labor and supervision to perform preventive maintenance and load bank testing for four (4) 3508 cat diesels and (2) Cumming diesels. Contractor to perform work during normal business hours: 7:00 a.m. to 4:30 p.m. Generators: Manufacturer Caterpillar Location Building 1A Engine model 3508 Generator model sr-4 Serial # - 5ua02317 KVA 850 kw 680 amp 1022 voltage 480/277 Manufacturer Caterpillar Location Building 1A Engine model 3508 serial # -23z05796 Generator model sr-4 serial # - 5ua02316 KVA 850 kw 680 amp 1022 voltage 480/277 Manufacturer Caterpillar Location Building 1A Engine model 3508 serial # 23z06631 Generator model sr-4b serial # - 1bn00578 KVA 937kw 750 amp 1127 voltage 480/277 Manufacturer Caterpillar Location Building 1A Engine model 3508 serial # - 23z06636 Generator model sr-4b serial # - 1bno00579 KVA 937kw 750 amp 1127 voltage 480/277 Manufacturer Cummins Location Building 5 Engine model st50 serial # - 23z06636 Generator model 440fdr5045ffw serial # - hm90044111/245 KVA 175 kw 140 amp -210 voltage 480/277 Manufacturer Cummins Location Building 7 Engine model vta28g51 serial # - 37108835 Generator model 680fdr7126jjw serial # - pl195112210.903 KVA 575 kw 460 amp 692 voltage 480/277 The Contractor will be required to show proof that he is capable and has at least five years experience repairing and performing preventive maintenance on these types of emergency generators. This Presolicitation Notice is being posted in anticipation of RFP VA-249-07-RP-0139. The solicitation shall be posted on or about August 21,2008, with responses due September 2, 2008. Any and all questions pertaining to the solicitation must in writing and sent via e-mail to donald.larson@va.gov or mailed to Department of Veterans Affairs VISN 9 Acq. Svc. Ctr. ATT: Donald R. Larson Bldg #5 Rm 174, 3400 Lebanon Pike, Murfreesboro, TN 37129.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=68c03893e354e1f3ed647c04d2261669&tab=core&_cview=1)
 
Record
SN01641362-W 20080817/080815223021-68c03893e354e1f3ed647c04d2261669 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.