Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 20, 2008 FBO #2459
SOLICITATION NOTICE

61 -- Power Amps

Notice Date
8/18/2008
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
335311 — Power, Distribution, and Specialty Transformer Manufacturing
 
Contracting Office
Department of the Air Force, Air Combat Command, 55 CONS, 101 Washington Sq Bldg 40, Offutt AFB, Nebraska, 68113-2107, United States
 
ZIP Code
68113-2107
 
Solicitation Number
F3HRA18193AG01
 
Archive Date
9/9/2008
 
Point of Contact
James Wages, Phone: 402-232-6484, Andrew L Peterson,, Phone: 402-232-8659
 
E-Mail Address
james.wages@offutt.af.mil, andrew1.peterson@offutt.af.mil
 
Small Business Set-Aside
Service-Disabled Veteran-Owned
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation Sub Part 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a WRITTEN SOLICITATION WILL NOT BE ISSUED. Solicitation number F3HRA18193AG01 is issued as a request for quotations. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-25. The NAICS Code is 335311 and the NAICS size standard is 750 Employees. 55 CONS intends to issue a firm fixed priced purchase order for delivery and installation of the following items: Purchase, deliver, and install seven (7) 100kVA power distribution units (PDU) with remote monitoring capability, for AFWA Bldg 185. The PDUs must equal or exceed the currently installed equipment, which are Liebert FPC(s), model FPA11C341B; and must have the following features: - AC input 480V (3-phase, 3-wire plus ground) - AC output 208V (3-phase, 4-wire plus ground) - Main input power junction box w/ 10-ft input cable - K20 double-shielded isolation transformer suitable for highly non-linear loads - Power Monitor Panel w/ local Emergency Power Off switch, comm. interface to a Liebert site monitor - Three (3) 42-pole panelboard(s) for GE plug-in circuit breakers w/ 10 kAIC panelboard main breaker - Side panels - both sides - Perforated Doors - Casters and leveling feet Critical note: The PDU monitoring capability must also equal or exceed the current equipment, and must integrate into the enterprise monitoring system; which uses Raptor RIS-6 (Modbus-Bacnet convertors). All quotes must be received NLT Monday, 25 August 2008, at 1:00 pm (CST), and sent electronically via e-mail, if possible, to james.wages@offutt.af.mil or faxed to (402) 294-7280. All potential bidders are reminded, in accordance with DFARS 252.204-7004, Required Central Contract Registration, that lack of registration in the CCR database BY Monday, 25 August 2008, at 1:00 pm (CST) will make a offeror ineligible for award. Also, the contractor must have the NAICS code listed in this solicitation on their CCR Registration. The following provisions and clauses apply to this acquisition: FAR 52.211-6 Brand Name or Equal; FAR 52.212-1, Instructions to Offerors Commercial; FAR 52.212-2, Evaluation- Commercial Items, (a. Price and delivery, in order of importance); (Offerors must include a complete copy of 52.212-3, Offeror Representation and Certifications -- Commercial Items with offer which can be found at http://farsite.hill.af.mil/vffara.htm); FAR 52.212-4, Contract Terms and Conditions Required to Implement Status of Executive Orders -- Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes Or Executive Orders -- Commercial Items (DEVIATION); 252.212-7000 Offeror Representations and Certifications--Commercial Items; 252.225-7000, Buy American Act--Balance of Payments Program Certificate; 252.225-7001, Buy American Act and Balance of Payments Program;; 252.232-7003 Electronic Submission of Payment Requests; 252.247-7023, Transportation of Supplies by Sea. Please reference solicitation # F3HRA18193AG01 correspondence. No numbered notes are applicable to this acquisition. Any questions should be submitted to A1C James Wages at (402) 232-6484 or via email at james.wages@offutt.af.mil. Complete written quotations will be due and must be physically received by the 55th Contracting Squadron/LGCB, 101 Washington Square. Bldg 40, Offutt AFB 68113 NLT Monday, 25 August 2008, at 1:00 pm (cst). Quotations may be submitted via email to james.wages@offutt.af.mil or faxed to (402) 294-7280.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=cb29a62fce84e620fd3cfaef1ef84dcf&tab=core&_cview=1)
 
Place of Performance
Address: 101 Nelson Drive, Offutt AFB, Nebraska, 68113, United States
Zip Code: 68113
 
Record
SN01643416-W 20080820/080818220853-cb29a62fce84e620fd3cfaef1ef84dcf (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.