SOLICITATION NOTICE
41 -- Replace refrigeration units, FCI Schuylkill
- Notice Date
- 8/20/2008
- Notice Type
- Modification/Amendment
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of Justice, Bureau of Prisons, FCI Schuylkill, Interstate 81 and PA 901 West, PO Box 700, Minersville, Pennsylvania, 17954
- ZIP Code
- 17954
- Solicitation Number
- 21303-0015-08
- Response Due
- 8/26/2008 2:00:00 PM
- Archive Date
- 8/28/2008
- Point of Contact
- Lori H. Rarig, Phone: (570)544-7311, Betsy Woll, Phone: 570-544-7320
- E-Mail Address
-
lrarig@bop.gov, bwoll@bop.gov
- Small Business Set-Aside
- Total Small Business
- Description
- The follwoing questions were asked at a site visit for the above solicitation. 1. Are the new units going to be on the same pad? Yes unless they would not fit and then the it would the contractors responsibilty to correct this. 2. Any/all pipes going to be changed? Yes 3. Are we having trouble keeping the temps regulated? No 4. What temps are we looking for? -10 on the freezer & 34 on the cooler 5. Are the exising freezer/coolers all storage units and how hard are they used? They are all used very hard, for the storage of frozen and refridgerant food. 6.Is the product already chilled when the item is placed in the unit? Most of the time yes. 7. Why are the units being changed out? They are the orginal units when the instituion was built so we are upgrading to newer units. 8. Do we want environment friendly refrigerants? Yes 9. How old are the walk-in's? All but one were there since 1991 the other one was around 1993. 10. What are the exact size of the boxes? Feezer#1 Box 20x9x8, Cooler#2 22x19x8, Freeezer #3 22x17x8, Freezer #4 22x19x14, & Camp Cooler 11x11x8 11. What size compressor is in each existing unit? Freezer #1 208,30AMP, 10 GA, Cooler #2, 208,20AMP, 10 GA, evap-115, SP, 20AMP lights independent, Freezer #3 208,40 AMP, 8 GA, Freezer #4 208,50AMP, 8 GA and Camp Cooler 208, 30 AMP, 10 GA evap 115, SP 20AMP lights independent. NOTE: IT WILL BE ON THE CONTRACTOR TO PERFORM THEIR OWN LOAD CALCULATIONS. In the orginal solicitation refer back to page 4 under General Equipment Requirements, D also on page 2 under Description of work. 12 There are alot of bells and whistles on the requirements, do we really wants vendors to bid on all of these? Yes or equal to. Such as valuable speed fans on evaporators? This would be freezers only. Doors switch adn alarms, humitidy monitoring? Yes coolers only. 13. Are we going to monitor the temps remotely? We need to have the ability to hook up an alarm system. 14. What type of compressors are we looking for hermictic, scroll, or semi hermictic? We would like a bid on each to compare. 15. There must be electric heat tape on all drains. 16. Did we need/want all new lines? yes 17. Who is responsibile for drilling all the holes in walls etc? and who is responsible for electrical updating? Contractor will be responsible for all this is the need is there to change, if the equipment is adiqute to meet the new equipment sizes and safty and current protection requirements, this will not have to be changed. 18 Are we looking for the latest in technology in regards to energency efficient motors? Yes. The closing date for this solicitation will be August 26, 2008, no later then 2:00pm. local time.
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=f518c2ceb82534c16a315b722e322420&tab=core&_cview=1)
- Place of Performance
- Address: FCI Schuylkill, Interstate 81 & 901q, Minersville, Pennsylvania, 17954, United States
- Zip Code: 17954
- Record
- SN01646625-W 20080822/080820223251-f518c2ceb82534c16a315b722e322420 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |