Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 22, 2008 FBO #2461
SOLICITATION NOTICE

S -- Air Force Utilities Privatization Effort for Westover ARB Natural Gas Distribution System

Notice Date
8/20/2008
 
Notice Type
Presolicitation
 
NAICS
221210 — Natural Gas Distribution
 
Contracting Office
Department of the Air Force, Air Education and Training Command, Tyndall AFB Contracting Squadron, 501 Illinois Ave, Ste 5, Bldg 647, Tyndall AFB, Florida, 32403-5526
 
ZIP Code
32403-5526
 
Solicitation Number
FA3002-08-R-0032
 
Point of Contact
Mary D Dent,, Phone: 850-283-6624, Robert Gable,, Phone: 850-283-6605
 
E-Mail Address
mary.dent@tyndall.af.mil, robert.gable@tyndall.af.mil
 
Small Business Set-Aside
N/A
 
Description
Air Force Utilities Privatization Effort for Westover ARB Natural Gas Distribution System – FA3002-08-R-0032 Contracting Office - AETC CONS/LGCT, AFCESA Support Flight, 136 Barnes Avenue, Building 856 Annex, Tyndall AFB, FL 32403 NAICS 221210 Classification Code - S Utilities and Housekeeping Services SB Size Standard - 500 employees POC information Mary Helen Dent, Contracting Officer; email is preferred method of communication mary.dent@tyndall.af.mil; COMM 850-283-6624; FAX 850-283-6466 AETC CONS/LGCT, AFCESA Support Flight, 136 Barnes Avenue, Building 856 Annex, Tyndall AFB, FL 32403 is soliciting competitive offers for Air Force Utility Privatization Westover ARB, MA Natural Gas Distribution System. Anticipated release of RFP is 30 Sep 08. Privatization is defined as the conveyance of a utility system to a municipal, private, regional, district, or cooperative utility company or other entity. The conveyance may consist of all right, title, and interest of the United States in the utility system. Utility Privatization (UP) will be accomplished in accordance with 10 U.S.C. §2688 Utility Systems: Conveyance Authority. Contract term is anticipated at 50 years. The following is a brief description of the system to be privatized: The Westover ARB natural gas distribution system consists of all appurtenances physically connected to the distribution system from the point in which the distribution system enters the Installation and Government ownership currently starts at the point of demarcation, defined by the Right of Access. The system may include, but is not limited to, pipelines, valves, regulators, and meters. The actual inventory of items sold will be in the bill of sale at the time the system is transferred. The following description is included to provide the Contractor with a general understanding of the size and configuration of the distribution system. There are no items specifically excluded from the natural gas distribution system privatization. Natural gas is supplied to Westover ARB by Bay State Gas through two metering points. One metering point is near the Central Ave. Gate (Building 2765). A second metering point is at the Westover Club. The meters are owned by Bay State Gas. The main distribution system receives gas at approximately 50 pounds per square inch gauge (PSIG). Natural gas is used to meet space and water heating requirements on Base. The natural gas utility system at Westover ARB has no pressure problems during peak winter loads. Bay State Gas maintains odorization at the metering points. A study of the capacity of the natural gas system at Westover ARB to support future operations when BRAC related mission additions are complete was finalized in February 2008. This study concluded that the proposed capital projects represent a potential increase in peak gas flow of about 76 percent compared to the existing theoretical peak flow, and that several modifications were recommended to allow the existing system to accommodate the increased demand. The natural gas utility system at Westover ARB consists of polyethylene (PE) pipe that is owned by Westover ARB. Natural gas utility mains and service lines are approximately 3 to 6 feet below grade. Valves are also made of plastic. Some of the pipe is buried with marker tape and tracer wire, but a majority of the system does not have marker tape or functioning tracer wire because it was installed using jack and bore techniques. The distribution system is looped so that most buildings can be fed from at least two different paths. There are no cathodic protection or odorization facilities at Westover ARB. A short segment of metal pipe delivers natural gas to the west side of building 3505 on the north side of the base. This pipe does not have cathodic protection so it is being programmed for replacement. Place of Performance – Westover ARB, Chicopee, MA Postal Code - 01022
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=ef5146bce75e594eed06b2b6013b810d&tab=core&_cview=1)
 
Place of Performance
Address: Westover ARB, Chicopee, Massachusetts, 01022, United States
Zip Code: 01022
 
Record
SN01646250-W 20080822/080820222444-ef5146bce75e594eed06b2b6013b810d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.