SPECIAL NOTICE
99 -- This is for the installation of a concrete slab at Hewitt Hall, NWC. This award is going to an 8a contractor vis sole source under the MoU with the SBA dated 28 FEB 2007.
- Notice Date
- 9/4/2008
- Notice Type
- Special Notice
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- Department of the Navy, Naval Facilities Engineering Command, NAVFAC Mid-Atlantic, ROICC Newport, N40085 NAVFAC MID-ATLANTIC, ROICC NEWPORT Naval Activities Building #1 Newport, RI
- ZIP Code
- 00000
- Solicitation Number
- N4008508M2654
- Small Business Set-Aside
- N/A
- Description
- BLDG 991 CHIHewitt Hall Garage Concrete Pad Contractor shall provide all labor, materials, and equipment to construct a fixed form, 4-3/4" - 6" thick (including joints, finishing and curing), concrete pad approximately 138'x 115' in Hewitt Garage indicated in the attachment..Location: Hewitt Parking Garage.Scope: Pour ~4-3/4" - 6" concrete floor (on grade to match existing curb height of vestibule) over existing concrete deck. This will carry floor height to be the same floor height as that existing in the elevator vestibule lobby. Existing floor drains to be plugged. Reinforce concrete with one layer of 6 x 6-W4.0 x W4.0 welded wire fabric. Quantity ~ 15,900 sf. In some areas thickness will vary due to sloping at floor drains (ranges from ~4-3/4" - 6"). Bounded on three sides by existing structure: elevator vestibule wall in Hewitt Basement, rear of parking garage, and side of parking garage. The fourth side of the rectangular floor to be poured will result in approximately 4" - 4-3/4" curb to the existing garage. During all work progress the contractor shall be responsible for building contents protection and clean up of the surrounding jobsite and dumpsite areas on a daily basis. Contractor shall also be expected to restore all damaged areas of existing structures, equipment, finishes caused by work progress to their pre-construction condition at the contractor's expense and verified as such by the Contracting Officer. Contractor shall at the end of the project remove and dispose of all debris generated at the jobsite from the Naval War College premises.Safety Requirements: Contractor shall refer to and comply with the NAVFAC Safety Requirements Reference USACE Safety Manual #EM 385-1-1, dated November 2003, during all phases of work progress.
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=17bc606afc3e0b549c3d2db4729b9ed0&tab=core&_cview=1)
- Record
- SN01660068-W 20080906/080904222457-17bc606afc3e0b549c3d2db4729b9ed0 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |