SOLICITATION NOTICE
42 -- Modification to Presolicitation Notice, W52H09-08-T-0364, Heat Shield Assembly, NSN 4230-01-171-2543, PN 5-45-5210, for a five-year Indefinite Delivery, Indefinite Quantity (IDIQ) type contract.
- Notice Date
- 9/17/2008
- Notice Type
- Presolicitation
- NAICS
- 335991
— Carbon and Graphite Product Manufacturing
- Contracting Office
- Department of the Army, U. S. Army Materiel Command, U.S. Army TACOM Life Cycle Management Command - Rock Island, TACOM - Rock Island, ATTN: AMSTA-AQ-AR, Rock Island Arsenal, Rock Island, IL 61299-7630
- ZIP Code
- 61299-7630
- Solicitation Number
- W52H09-08-T-0364R
- Response Due
- 10/8/2008
- Archive Date
- 12/7/2008
- Point of Contact
- Jane E. Nelson, 309-782-5626<br />
- Small Business Set-Aside
- N/A
- Description
- Heat Shield Assembly, NSN 4230-01-171-2543, PN 5-45-5210, and supports the M17A3 Lightweight Decontamination Apparatus, NSN 4230-01-346-3122, PN 5-45-5299-40. Modification to Presolicitation Notice, W52H09-08-T-0364, Heat Shield Assembly, NSN 4230-01-171-2543, PN 5-45-5210, for a five-year, Indefinite Delivery, Indefinite Quantity (IDIQ) type contract. Original Synopsis and Presolicitation Notice posted to ASFI/FBO, April 24, 2008. This notices announces the issuance of Amendment 0008 and provides for the re-synopsis and re-issuance of this request for quotation (RFQ) that was originally issued on 2008MAY12 with quotes due by 2008AUG18 in accordance with its Amendment 0007. Any and all interested prospective contractors shall submit quotes in accordance with the previously issued pre-solicitation notice and modifications, thereto; and the solicitation, including Amendments 0001 through 0008. Any previously submitted quotes, dated prior to 2008SEP17, will no longer be considered for award. All or part of this action is a FY09 requirement. The Heat Shield Assembly is used on a decontamination system and consists of formed Heat Shields, P/Ns 5-45-5209 & 5-45-4879; Support, P/N 5-45-5208; Spacer, P/N 5-45-5207; and Bottom, P/N 5-45-5206. Material includes stainless steel tubing and stainless steel sheet. The heat shield assembly is a 16.535 inch diameter cylinder of 0.0355 thickness grade 304 stainless steel. The cylinder has one embossed ring around the circumference of.394 widths and.197 depths. Resistance seam welding and spot welding is required. Requirements are for a five-year Indefinite Delivery, Indefinite Quantity (IDIQ) type contract with a guaranteed minimum ordering quantity is 10 each and the maximum ordering quantity is 500 each for the total period of performance. FOB is Destination to New Cumberland Army Depot, New Cumberland, PA 17070-5001. Interested prospective contractors are required a nd shall have a current certification of Military Critical Technical Data Agreement, DD2345, and Central Contractor Registration. Distribution Statement X is applicable to this items Technical Data Package (TDP). Distribution is authorized to US government organizations and private individuals or enterprises eligible to obtain export-controlled technical data in accordance with DoD Directive 5230.25. Export Control Warning Notice always applies for Distribution Statement X. Export Control Warning Notice: Technical data can only be distributed to contractors who have a current DD 2345, Militarily Critical Technical Data Agreement on file with Defense Logistics Information Service (DLIS). Technical data that are export-controlled must be marked with an export control warning notice. This statement identifies technical data which the DoD will withhold from public release using authority in 10 U.S.C. 130. The Governments right to use, modify, reproduce, release, perform, display, or disclose such technical data are restricted for the Contractor/their subsidiaries/or sub-contractors at every level. Any reproduction of technical data or portions thereof marked with these legends must also reproduce these legends on such technical data. This solicitation is issued electronically in accordance with FAR 4.502 and 5.102. Vendors wishing an electronic copy may access and download from the following address via the internet: https://aais.ria.army.mil/aais/SOLINFO/index.htm.
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=e93ec61d45c9c1d8e6fc0f444c973e65&tab=core&_cview=1)
- Place of Performance
- Address: TACOM - Rock Island ATTN: AMSTA-AQ-AR, Rock Island Arsenal Rock Island IL<br />
- Zip Code: 61299-7630<br />
- Zip Code: 61299-7630<br />
- Record
- SN01673873-W 20080919/080917222254-e93ec61d45c9c1d8e6fc0f444c973e65 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |