SOLICITATION NOTICE
H -- PRESSURE BOILERS
- Notice Date
- 9/19/2008
- Notice Type
- Modification/Amendment
- NAICS
- 811310
— Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Contracting Office
- Department of Veterans Affairs, Bedford VAMC, ENRM Department of Veterans Affairs Medical Center, Department of Veterans Affairs;VAMC Bedford;200 Springs Road;Bedford MA 01730
- ZIP Code
- 01730
- Solicitation Number
- VA-241-08-RQ-0440
- Response Due
- 9/26/2008
- Archive Date
- 11/25/2008
- Point of Contact
- Sandra CantwellContract Specialist<br />
- Small Business Set-Aside
- N/A
- Description
- REFERENCE PAGE 1, BLOCK 8, CHANGE FROM: 09-15-2008 TO READ: 09-26-2008 REFERENCE PAGE(S) 5 - 7, SCOPE OF WORK, REPALACE WITH REVISED SCOPE OF WORK DATED 9/17/08 HIGH-LOW BOILERS REVISED 9/17/08 THE FOLLOWING SCOPE OF WORK FOR ACCIDENT INSPECTIONS FOR THE HIGH & LOW BOILERS LOCATED BLDGS.# 22 & 70 PLANT ARE AS FOLLWS RE: 518-09-1-4829-0016 SERVICE CONTRACT: MAINTENANCE SERVICE AGREEMENT FOR INSPECTIONS FOR PERIOD 10-01-08 TO 9/30/09 FOR INSPECTIONS OF HIGH AND LOW PRESSURE BOILERS AT BLDG.# 70 AND BLDG.# 22. REFER TO ATTACHED/SUBMITTED SCOPE OF WORK VENDOR WILL NEED TO PICK UP A VISTOR BADGE AND PARKING PERMIT AT THE VA POLICE STATION IN BUILDING 78 ROOM B14I. VENDOR WILL BE REQUIRED TO CHECK IN AT BUILDING 80 ROOM 110 DURING NORMAL TOUR OF DUTY AND WITH THE DUTY ENGINEER (USRO) DURING OFF TOUR WITHOUT EXCEPTION. VENDOR HAS TO MEET ALL REQUIREMENTS OF OSHA 10 HOURS SAFETY COURSE. A. SERVICE: 1. TO PROVIDE LABOR, MATERIALS, TOOLS, TRAVEL AND SUPERVISION TO PERFORM INTERNAL/EXTERNAL OPERATIONAL INSPECTIONS FOR TWO CLEAVER BROOKS 700 HP HIGH PSI BOILERS, (DELETION) **** A THIRD CLEAVER BROOKS BOILER WILL BE ADDED FOR INSPECTION ON 10-01-09. AND ONE HB SMITH SECTIONAL TYPE LOW PSI BOILERS. HIGH PSI BOILERS ARE LOCATED IN BUILDING 22 AND LOW PSI BOILERS ARE LOCATED IN BUILDING 70. 2. INSPECTION WILL INCLUDE FURNANCE AND OTHER INTERNAL SURFACES, CLOSURES AND ACCESSORIES. INSPECT EXTERIOR OF UNIT, CASING, SUPPORT, CLOSURES, ACCESSORIES, VALVES, AND CONTROLS. 3. INSPECT DEAERATOR AND WET MAGNETIC PARTICLE TESTING OF WALLS OF PRESSURE VESSEL INTERIOR. THIS IS A ONE TIME SERVICE. VENDOR WILL INVOICE AFTER COMPLETION OF PROVENT AND PROVIDE THE VA MEDICAL CENTER WITH A FULL DETAIL REPORT OF THE RESULTS ACCORDING TO A.S.M.E. AND NATIONAL BOARD. 4. INSPECT BOILER FOULING AND COMBUSTION GAS FLOW. 5. INSPECT FOR TUBE LEAK TEST. 6. INSPECT DRUMS, WELDS, THICKNESS OF SHELL FOR CORROSION. 7. INSPECT FOR SCALE OR CORROSION IN DRUMS, SHELLS, OR TUBES. B. INSPECT BOILER ECONOMISER ON BOILER #1 AND #2. C. SPECIFICATIONS: 1. THERE WILL BE THREE INTERNAL & EXTERNAL INSPECTIONS PER YEAR. 2. THIS WILL ALSO INCLUDE THE INTERNAL INSPECTION OF (DELETION) OF DA TANK ONCE EVERY 6 YEARS. NEXT TEST DUE MAY 2013. 3. BOILER INSPECTIONS WILL BE DONE DURING BUSINESS HOURS (8-4, M-F). (DELETION) MUST BE PRESCHEDULED WITH THE C.O.T.R. ALL WORK MUST BE PERFORMED BY BOARD CERTIFIED INSPECTOR. (NATIONAL BOARD OF BOILER INSPECTORS) (NBBI)AND IN COMPLIANCE ASME STANDARDS.
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=cedce7354d5164686cde86d0b31397d7&tab=core&_cview=1)
- Place of Performance
- Address: DEPARTMENT OF VETERANS AFFAIRS;VA MEDICAL CENTER;200 SPRINGS ROAD;BEDFORD, MA<br />
- Zip Code: 01730<br />
- Zip Code: 01730<br />
- Record
- SN01676700-W 20080921/080919221931-cedce7354d5164686cde86d0b31397d7 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)