SOURCES SOUGHT
41 -- PARTICULATE FUME HOOD WITH HIGH OUTPUT HEPA SYSTEM
- Notice Date
- 9/25/2008
- Notice Type
- Sources Sought
- NAICS
- 333411
— Air Purification Equipment Manufacturing
- Contracting Office
- Department of Energy, National Security Technologies LLC (DOE Contractor), National Security Technologies LLC, PO Box 98521, Las Vegas, Nevada, 89193
- ZIP Code
- 89193
- Solicitation Number
- 202028-TB-08
- Archive Date
- 10/17/2008
- Point of Contact
- Trevor A Braswell, Phone: 702-295-3339
- E-Mail Address
-
BrasweTA@nv.doe.gov
- Small Business Set-Aside
- Total Small Business
- Description
- INTERESTED VENDORS SHALL SUBMIT PRODUCT DATA SHEETS FOR LIKE OR SIMILAR PRODUCTS AS SPECIFIED BELOW. PARTICULATE FUME HOOD WITH HIGH OUTPUT HEPA SYSTEM SPECIFICATIONS: • Dimensions: 72" L x 35 ½" W x 79" H • Opening: 14 ¾" x 70" • Face Velocity Average > 200 feet/min • Filter Train includes: 11 ½" x 24" x 24" - 99.97% Nuclear Grade HEPA and 4" x 24" x 24" pre-filter. • Particulate hood, plenum, filter section, and blower cabinet are fabricated of stainless steel. • Opening cover swings up and rests on top of unit when unit is operational. • Swivel Caster Wheels may be locked for ease of moving unit. • Operating performance gauges offer indication of HEPA restrictions (dirty filter), pre-filter restrictions, and overall performance. Audible and visible alarms indicate when performance is reduced due to dirty filters. • Electrical control box with indicator lights included. THE FOLLOWING DOCUMENTATION, TEST REPORTS, AND CERTIFICATIONS ARE TO BE INCLUDED: • Drawing, components, and dimensions (AS BUILT) • Electrical wiring diagram • Grounding continuity test, UL Standard 1017 • Dielectric test, UL Standard 1017 • Electrical parts listing • Control systems and operational information o Control panel performance o Electrical controls • Filter change out, door system, and locking mechanism • Air flow test per ASME N510 (air flow validation) • Hood entrance air flow test per ASHRAE 110-1995 • Total system DOP test per ASME N510 (HEPA efficiency validation using NPO supplied HEPA and seal/seam check). HEPA sent directly to site from testing facility. • Independent testing service report • Test report DOE-STD-3020-97, supplied by others (per contract) • Test report, HEPA performance, per ASME-AG-1, supplied by others (per contract) • Certification of performance • Certification of quality per DOE order 414-1C
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=8e001ea3e8605bae7a8081d626d30331&tab=core&_cview=1)
- Place of Performance
- Address: Mercury, Nevada, 89023, United States
- Zip Code: 89023
- Zip Code: 89023
- Record
- SN01681491-W 20080927/080925222410-8e001ea3e8605bae7a8081d626d30331 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |