41 -- PARTICULATE FUME HOOD WITH HIGH OUTPUT HEPA SYSTEM

Notice Date
9/25/2008
 
Notice Type
Sources Sought
 
NAICS
333411 — Air Purification Equipment Manufacturing
 
Contracting Office
Department of Energy, National Security Technologies LLC (DOE Contractor), National Security Technologies LLC, PO Box 98521, Las Vegas, Nevada, 89193
 
ZIP Code
89193
 
Solicitation Number
202028-TB-08
 
Archive Date
10/17/2008
 
Point of Contact
Trevor A Braswell, Phone: 702-295-3339
 
E-Mail Address
BrasweTA@nv.doe.gov
 
Small Business Set-Aside
Total Small Business
 
Description
INTERESTED VENDORS SHALL SUBMIT PRODUCT DATA SHEETS FOR LIKE OR SIMILAR PRODUCTS AS SPECIFIED BELOW. PARTICULATE FUME HOOD WITH HIGH OUTPUT HEPA SYSTEM SPECIFICATIONS: • Dimensions: 72" L x 35 ½" W x 79" H • Opening: 14 ¾" x 70" • Face Velocity Average > 200 feet/min • Filter Train includes: 11 ½" x 24" x 24" - 99.97% Nuclear Grade HEPA and 4" x 24" x 24" pre-filter. • Particulate hood, plenum, filter section, and blower cabinet are fabricated of stainless steel. • Opening cover swings up and rests on top of unit when unit is operational. • Swivel Caster Wheels may be locked for ease of moving unit. • Operating performance gauges offer indication of HEPA restrictions (dirty filter), pre-filter restrictions, and overall performance. Audible and visible alarms indicate when performance is reduced due to dirty filters. • Electrical control box with indicator lights included. THE FOLLOWING DOCUMENTATION, TEST REPORTS, AND CERTIFICATIONS ARE TO BE INCLUDED: • Drawing, components, and dimensions (AS BUILT) • Electrical wiring diagram • Grounding continuity test, UL Standard 1017 • Dielectric test, UL Standard 1017 • Electrical parts listing • Control systems and operational information o Control panel performance o Electrical controls • Filter change out, door system, and locking mechanism • Air flow test per ASME N510 (air flow validation) • Hood entrance air flow test per ASHRAE 110-1995 • Total system DOP test per ASME N510 (HEPA efficiency validation using NPO supplied HEPA and seal/seam check). HEPA sent directly to site from testing facility. • Independent testing service report • Test report DOE-STD-3020-97, supplied by others (per contract) • Test report, HEPA performance, per ASME-AG-1, supplied by others (per contract) • Certification of performance • Certification of quality per DOE order 414-1C
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=8e001ea3e8605bae7a8081d626d30331&tab=core&_cview=1)
 
Place of Performance
Address: Mercury, Nevada, 89023, United States
Zip Code: 89023
 
Record
SN01681491-W 20080927/080925222410-8e001ea3e8605bae7a8081d626d30331 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.