Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 27, 2008 FBO #2497
DOCUMENT

S -- Air Force Utility Privatization Effort for Natural Gas Distribution System at Westover ARB - Solicitation

Notice Date
9/25/2008
 
Notice Type
Solicitation
 
NAICS
221210 — Natural Gas Distribution
 
Contracting Office
Department of the Air Force, Air Education and Training Command, HQ AFCESA, 139 Barnes Dr, Suite 1, Building 856 Annex, Tyndall AFB, Florida, 32403-5319
 
ZIP Code
32403-5319
 
Solicitation Number
FA3002-08-R-0032
 
Archive Date
1/9/2009
 
Point of Contact
Mary D Dent, Phone: 850-283-6624
 
E-Mail Address
mary.dent@tyndall.af.mil
 
Small Business Set-Aside
N/A
 
Description
*******Please note that the synopsis for this requirement was posted 20 Aug 08 under the same solicitation number; however, it was posted under the incorrect Contracting Office. Due to the fact that this has been posted over 30 days, the CO has determined that the FAR 5 requirement has been met and is issuing the solicitation.******** Privatization is defined as the conveyance of a utility system to a municipal, private, regional, district, or cooperative utility company or other entity. The conveyance may consist of all right, title, and interest of the United States in the utility system. Utility Privatization (UP) will be accomplished in accordance with 10 U.S.C. §2688 Utility Systems: Conveyance Authority. Contract term is anticipated at 50 years. The following is a brief description of the system to be privatized: The Westover ARB natural gas distribution system consists of all appurtenances physically connected to the distribution system from the point in which the distribution system enters the Installation and Government ownership currently starts at the point of demarcation, defined by the Right of Access. The system may include, but is not limited to, pipelines, valves, regulators, and meters. The actual inventory of items sold will be in the bill of sale at the time the system is transferred. The following description is included to provide the Contractor with a general understanding of the size and configuration of the distribution system. There are no items specifically excluded from the natural gas distribution system privatization. Natural gas is supplied to Westover ARB by Bay State Gas through two metering points. One metering point is near the Central Ave. Gate (Building 2765). A second metering point is at the Westover Club. The meters are owned by Bay State Gas. The main distribution system receives gas at approximately 50 pounds per square inch gauge (PSIG). Natural gas is used to meet space and water heating requirements on Base. The natural gas utility system at Westover ARB has no pressure problems during peak winter loads. Bay State Gas maintains odorization at the metering points. A study of the capacity of the natural gas system at Westover ARB to support future operations when BRAC related mission additions are complete was finalized in February 2008. This study concluded that the proposed capital projects represent a potential increase in peak gas flow of about 76 percent compared to the existing theoretical peak flow, and that several modifications were recommended to allow the existing system to accommodate the increased demand. The natural gas utility system at Westover ARB consists of polyethylene (PE) pipe that is owned by Westover ARB. Natural gas utility mains and service lines are approximately 3 to 6 feet below grade. Valves are also made of plastic. Some of the pipe is buried with marker tape and tracer wire, but a majority of the system does not have marker tape or functioning tracer wire because it was installed using jack and bore techniques. The distribution system is looped so that most buildings can be fed from at least two different paths. There are no cathodic protection or odorization facilities at Westover ARB. A short segment of metal pipe delivers natural gas to the west side of building 3505 on the north side of the base. This pipe does not have cathodic protection so it is being programmed for replacement.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=c923e12b730633e5d5e3e0f1bb2647ca&tab=core&_cview=1)
 
Document(s)
Solicitation
 
File Name: Solicitation FA3002-08-R-0032 (FA3002-08-R-0032 Westover Gas.doc)
Link: https://www.fbo.gov//utils/view?id=2cb0f98c4c1a602768cab0c3fd748b6b
Bytes: 464.50 Kb
 
File Name: Attachment J1 Inventory (Attachment J1 Westover Gas.doc)
Link: https://www.fbo.gov//utils/view?id=e828b572e29b4348f587903cad6ea66f
Bytes: 168.50 Kb
 
File Name: Attachment J2 Schedule 1 (Attachment J2 Schedule 1 Utility Svc Charge.doc)
Link: https://www.fbo.gov//utils/view?id=6a5f1a384338b8d450e5e1ea9572d53b
Bytes: 27.50 Kb
 
File Name: Attachment J3 Schedule 2 (Attachment J3 Schedule 2 Renewals and Replacements.doc)
Link: https://www.fbo.gov//utils/view?id=af8291f0e4250b7d48d3c6c5f8473251
Bytes: 61.00 Kb
 
File Name: Attachment J4 Schedule 3 (Attachment J4 Schedule 3 ISDC and Transition.doc)
Link: https://www.fbo.gov//utils/view?id=c020c1d2d7ae669e5f06d6cb7de7e32d
Bytes: 30.00 Kb
 
File Name: Attachment J5 Schedule 4 (Attachment J5 Schedule 4 Recoverable Portion of Purchase Price.doc)
Link: https://www.fbo.gov//utils/view?id=e2ceb9276fc41c4d411f3087b360cf90
Bytes: 27.50 Kb
 
File Name: Attachment J6 Schedule 5 (Attachment J6 Schedule 5 50 Yr Charges to Government.doc)
Link: https://www.fbo.gov//utils/view?id=59368cf16700cbd3ca2c34d3aef9a529
Bytes: 59.00 Kb
 
File Name: Attachment J38 Federal Equivalents (Attachment J38FederalEquivalents.pdf)
Link: https://www.fbo.gov//utils/view?id=2bd15e6618bb95b8bca54462d0999f6a
Bytes: 160.47 Kb
 
File Name: Attachment J39 PPQ (J39 Westover Gas PPQ.doc)
Link: https://www.fbo.gov//utils/view?id=d2a49baca71e0d9a4859c6dce426d24b
Bytes: 42.00 Kb
 
File Name: Attachment J40 Sample SF294 (Attachment J40 sf294.pdf)
Link: https://www.fbo.gov//utils/view?id=f738412c51515ffc91aac9a8574197cf
Bytes: 145.17 Kb
 
File Name: Attachment J41 Sample 295 (Attachment J41 sf295.pdf)
Link: https://www.fbo.gov//utils/view?id=32ace9beac639d7356039ad51b9defba
Bytes: 434.60 Kb
 
File Name: Attachment J42 Draft Bill of Sale (J42-Draft%20Bill%20of%20Sale_7.pdf)
Link: https://www.fbo.gov//utils/view?id=7a44ff134d38a789209968e57e6aaa6b
Bytes: 57.97 Kb
 
File Name: Attachment J44 Westover Wage Determination (Attachment J44 Westover WD.txt)
Link: https://www.fbo.gov//utils/view?id=69e1979742787990becc14ed9c624687
Bytes: 38.48 Kb
 
File Name: Attachment J45 Legislative Authority 10 USC 2688 (Attachment J 45 10 USC 2688 as amended .doc)
Link: https://www.fbo.gov//utils/view?id=30e4477f3533a1b4f41bdde46237f8f0
Bytes: 41.50 Kb
 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Westover ARB, Massachusetts, 01022, United States
Zip Code: 01022
 
Record
SN01681845-W 20080927/080925223212-c923e12b730633e5d5e3e0f1bb2647ca (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.