SOLICITATION NOTICE
W -- RENTAL OF AN ENVIRONMENTAL CONTAINMENT FOR 40 DAYS INCLUDING 4 MOVES - USS EISENHOWER (CVN-69)
- Notice Date
- 10/23/2008
- Notice Type
- Presolicitation
- NAICS
- 336611
— Ship Building and Repairing
- Contracting Office
- Department of the Navy, Naval Sea Systems Command, Mid Atlantic Regional Maintenance Center, N40025 MID-ATLANTIC REGIONAL MAINTENANCE CENTER - NORFOLK, VA PO Box 215 Building 51, 2nd Floor Portsmouth, VA
- ZIP Code
- 00000
- Solicitation Number
- N4002509Q0005
- Response Due
- 11/7/2008
- Archive Date
- 12/10/2008
- Point of Contact
- KATHY SMITH (LAURA) (757) 396-5041 X 412 LINDA O TERRY X 434RAE STRUEBING X 493DIANE CHAMPION X 421
- Small Business Set-Aside
- N/A
- Description
- COMPLETE AND DETAILED DESCRIPTION OF SERVICES NEEDED: 1. Request a containment enclosure, up and running with the check point of paragraph G accomplished, three days after the ship's arrival, to support 100,000 square feet of flight deck type "G" area nonskid replacement. The Containment Enclosure dimensions shall be 320 feet by 85 feet. Initial set up with four moves shall be accomplished on board the ship's flight deck. A. The containment enclosure structure must be modular in design and configurable if necessary.B. It should be easily movable using small forklifts and / or manpower without breakdown and set-up delays.C. It must be constructed of light weight fire resistant materials and be designed to distribute the load over the covered area and to protect the new coating from damage. The total weight of the system must allow for a maximum point load of 1600 lbs/sqft. Pneumatic wheels must be soft enough to prevent damage to the new non-skid.D. Structure must be capable of spanning up to 320 feet long by 85 feet wide without internal support. Internal deck areas must be unobstructed to allow access, ten feet tall as a minimum clear height. The structure shall have as a minimum, one sealable access opening at each end, ten feet tall by twelve feet wide. E. Structure and containment fabric must be capable of withstanding 70 mph winds.F. Containment fabric must be easily repairable, sealable, and capable of containing and excluding pollutants.CHECK POINT (V) (G) Environmental Conditions Set. (At Initial set and Reset)G. Containment enclosure must be capable of establishing and maintaining a controlled environment in accordance with NSTM Chapter 634, table 634-3-6.CHECK POINT (V) (G) No Leaks Allowed. (At Initial Set and Reset)H. The enclosure must include an integral watertight seal around the base, capable of conforming to the deck and excluding all water from the work areas.I. Illumination inside the containment shall be a minimum of 50 foot candle power at the working surface.J. Air exchange, as a minimum of 4 complete exchanges per hour.2. The contractor shall be self sufficient. Electrical power may be purchased from NAVFAC MIDLANT: POC is Paul Milbourn, 757-445-7447. Set up an account for labor and commodities with comptroller at least one week in advance at 757-444-1271, X-3184 or X-3186.3. The contractor will be required to construct and set required environmental conditions of the enclosure initially over the Bow Cats' area, starting at the most forward point, plus four additional moves and reset of environmental conditions, on the starboard side including aircraft elevators one, two and three as directed by the SUPERVISOR to accomplish the task of replacing approximately 100,000 square feet of general area non-skid. 4. The contractor shall lift equipment directly to and from the flight deck due to Aircraft Elevator scheduled maintenance. 5. Ship's Force will provide 150 ft of pier lay down area.
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=334416ec7a48f868fba9be4a91d462e5&tab=core&_cview=1)
- Record
- SN01695654-W 20081025/081023220737-b68671d62189e5254633af5b98bda48a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |