Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF NOVEMBER 23, 2008 FBO #2554
SOLICITATION NOTICE

59 -- Paint Outdoor Metal Clad Switchgear - Paint Outdoor Metal Clad Switchgear

Notice Date
11/21/2008
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
335313 — Switchgear and Switchboard Apparatus Manufacturing
 
Contracting Office
Department of the Army, U. S. Army Materiel Command, Anniston Chemical Agent Disposal Facility (ANCDF), 3580 MORRISVILLE ROAD, Anniston, Alabama, 36201, United States
 
ZIP Code
36201
 
Solicitation Number
ANCDF-RFQ-WA9-0017
 
Point of Contact
Ashley M Rollins, Phone: 2562380721131
 
E-Mail Address
ashley.rollins@wancdf.com
 
Small Business Set-Aside
N/A
 
Description
Westinghouse Anniston (WA) is soliciting cost proposals for a vendor to perform the following scope of work: WA reserves the right not to award a subcontract after receipt of proposals. STATEMENT OF WORK Provide all labor, materials, tools, equipment and supervision required to perform the below scope. w/o 335502 PURPOSE OF PROCUREMENT The outdoor metal clad switchgear coatings have degraded and need to be re-painted. SCOPE OF WORK Westinghouse Anniston is soliciting the services of a qualified vendor paint 4160VAC/480VAC Double-Ended Outdoor Metal Clad Substations sizes from 500KVA, 1000 KVA, 1500 KVA to 2000 KVA. Some of the work may require working with an energized unit; therefore, the contractor will be required to give safety references showing background and experience in painting electrical equipment and in developing a safe plan to accomplish the task. A) This work will include removing existing rust, priming and painting, according to the original manufacturer's specifications, WANCDF Specification 16345-SC, Part 3.1 and Specification 09900-SC. B) Surface preparation to include cleaning mechanically with power tools according to SSPC SP 3. C) Coating system to be applied so that the DFT at any point is not less than 4.0 mils with the primer having a DFT of 1.5 mils. D) Reference specification TT-E-489 or SSPC-PAINT 21, TYPE I. E) MSDS sheets shall be submitted and pre approved before any material is brought on-site for use. F) Color to match existing, GRAY. The Vendor shall be required to submit a detailed, written, step by step plan for each specific switchgear, to the WANCDF Electrical Systems Engineer for approval before doing work. The Electrical Systems Engineer may, at times, require a submitted plan on a day to day basis, depending on the potential risks associated with work going on around a specific substation. Any switching required shall be planned and performed under the direct supervision of the Electrical Systems Engineer. All existing markings, Nameplates, Cautions Signs, Danger Signs, Arc Flash Tags, and Fan/Temp. Control Panels must be maintained. If needed, masking tape shall be used to protect areas. Note: All spray painting must be pre-approved on an incident basis. 1) The following OUTDOOR SUBSTATIONS are to be painted: SPS-SWGR-107A/107B AN-23-E-15, Sht. 1 of 1, MDB Filter SPS-SWGR-107 480V Switchgear Single Line AN-23-E-17 Elevation drawing for SPS-SWGR-107A/107B SPS-SWGR-103/104: AN-2-E-901, Sht. 1 of 1, PUB SPS-SWGR-103/104 480V Switchgear, Single Line Diagram, AN-2-E-646 Elevation drawing for SPS-SWGR-103 AN-2-E-647 Elevation drawing for SPS-SWGR-104 SPS-SWGR-105/106: AN-6-E-603, Sht. 1 of 1, PAS SPS-SWGR-105/106 4160V Switchgear Single Line Diagram, AN-6-E-610, Elevation drawing for SPS-SWGR-105 AN-6-E-611 Elevation drawing for SPS-SWGR-106 PPS-SWGR-104: AN-6-E-601, Sht. 1 of 1, PAS PPS-SWGR-104 4160V Switchgear Single Line Diagram AN-6-E-608 Elevation drawing for PPS-SWGR-104 PPS-SWGR-105: AN-6-E-602, Sht. 1 of 1, PAS PPS-SWGR-105 4160V Switchgear Single Line Diagram, AN-6-E-609, Elevation drawing for PPS-SWGR-105 PPS-TRSF-107: AN-2-E-901-SC Transformer and Switchgear for SPS-SWBD-900-SC Elevation drawings attached after Section C. SCHEDULE OF WORK: Each substation will be scheduled on a per week basis. QUESTIONS REGARDING THIS SCOPE OF WORK General Questions and questions regarding contractual matters, payments, site access, or required training should be directed to Ashley Rollins @ 256-238-0721 (Ext. 132). POC: Jerry B. Rickles @ 256-240-2386 ext. 2048 or Don McLemore @256-240-2386 ext. 2036
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=702b62c813f04bcfb83f0b9cf0c63655&tab=core&_cview=1)
 
Record
SN01708949-W 20081123/081121215830-702b62c813f04bcfb83f0b9cf0c63655 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.