Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 03, 2008 FBO #2564
SOLICITATION NOTICE

65 -- Sterile Custom Surgical Heart Packs

Notice Date
12/1/2008
 
Notice Type
Presolicitation
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
Department of Veterans Affairs, VA North Florida/South Georgia Health Care System, Department of Veterans Affairs No. Florida/So. Georgia Healthcare System, Department of Veterans Affairs;North FL/South GA Healthcare System;ATTN: Clifford Snipe (T-6);1601 S.W. Archer Road;Gainesville FL 32608-1197
 
ZIP Code
32608-1197
 
Solicitation Number
VA-248-09-RP-0072
 
Response Due
12/8/2008
 
Archive Date
1/7/2009
 
Point of Contact
Clifford Snipe352 376-1611 x7547<br />
 
Small Business Set-Aside
N/A
 
Description
The NF/SG Veterans Healthcare System, Malcolm Randall VA Medical Center, 1601 SW Archer Road, Gainesville, FL 32608 intends to negotiate with Medtronic, Inc, on a sole source basis pursuant to VAAR 873 & 38 USC 8153 and FAR 6.302-1 for Sterile Custom Surgical Heart Packs. The Custom Surgical Heart Pack consists of provided custom component kit #CK9454R3 that consist of various lengths of 1/4, 3/8 and 1/2 inch tubing; tubing end caps, one way valves, clamps and stopcocks; various tubing connectors; O2, prebypass and arterial filters (CB351 & CB1338); cardiotmy reservoir (CB1351); hemoconcentrator (HPH-400TS). All components are to be placed in line as shown in the drawing. All components in the pack are Carmeda coated (bio-active). No one else has Carmeda. It is the only Heparin bonded bio-active surface on the market. There are other heparin and non-coatings available but all are bio-passive. Carmeda is the only bio-active surface coating. Carmeda mimics natural endothelium such that blood does not recognize the circuit as a foreign surface thus limiting the "Systemic Inflammatory Response". This is unique to Carmeda and is achieved by the "End Point" attachment of the heparin molecule to the surface such that the reactive part of that molecule is in the blood flow path available to bind thrombin and antithrombin III thus mimicking natural endothelium (bio-active). The heparin used in Carmeda is also assayed to insure that the reactive portion of the heparin molecule is available on heparin used to produce Carmeda. The result is less bleeding and a reduced inflammatory response leading to fewer complications normally associated with cardiac surgery. The North American Industry Classification System (NAICS) number is 334510. This notice is NOT a request for competitive proposals. Parties may identify their interest, accompanied by supporting literature to the Contracting Officer no later than December 8, 2008, 4:30 PM EST. Responses should be sent to Clifford.Snipe@va.gov. No telephone responses will be accepted. Information received will be for the purpose of determining whether or not to conduct a competitive procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=2557ebb17299bee7b039a91824bb1ee0&tab=core&_cview=1)
 
Place of Performance
Address: North FL/South GA Healthcare System;1601 S.W. Archer Road;Gainesville FL 32608-1197<br />
Zip Code: 32608<br />
 
Record
SN01711925-W 20081203/081201215232-2557ebb17299bee7b039a91824bb1ee0 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.