Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 24, 2008 FBO #2585
SOURCES SOUGHT

J -- Maintenance and Waste Disposal Service

Notice Date
12/22/2008
 
Notice Type
Sources Sought
 
NAICS
562991 — Septic Tank and Related Services
 
Contracting Office
Department of the Air Force, Air Education and Training Command, Randolph AFB - 12th Contracting Office, 395 B Street West Suite 2, Randolph AFB, Texas, 78150-4525
 
ZIP Code
78150-4525
 
Solicitation Number
F3P3A68318A001
 
Archive Date
1/20/2009
 
Point of Contact
Andrea J. Davignon,, Phone: 210-652-8428, Rhonda F Chavez,, Phone: 210-652-5176
 
E-Mail Address
andrea.davignon@randolph.af.mil, rhonda.chavez@randolph.af.mil
 
Small Business Set-Aside
N/A
 
Description
Classification Code: J – Maintenance and Waste Disposal Contracting Office Address Department of the Air Force, Air Education and Training Command, 12th Contracting Squadron, 395 B Street West, Suite 2, Randolph AFB, TX, 78150-4302 Requirement. The Air Force is attempting to determine if capable and willing small business contractors are available to provide oil/water separator and septic holding tank maintenance services in support of 12 Civil Engineering Squadron for Randolph AFB, TX. Description. The Government reserves the right to decide whether or a not a SB set-aside based is appropriate based on responses to this notice. In order for the Government to make a SB set-aside determination, it is requested that SB concerns provide sufficient written information supporting their capability to perform. This information should as a minimum include (a) company name, address, point of contact and their telephone number and e-mail address; (b) provide past corporate and Government contract numbers with points of contact and current phone numbers; (c) degree of experience in oil/water separator and septic maintenance; (d) approximate annual gross revenue; (e) small business status (8(a), HUBZone, veteran-owned, women-owned, etc.); (f) comments indicating whether or not they would be likely to submit a proposal if a formal solicitation is forthcoming. Personnel will require a background check. The planned NAICS (North American Industry Classification System) code is 562991 with a business size standard of $7.0 million per year. All required information should be provided not later than COB 5 Jan 2009. Email is preferred. (Note: The description herein is a summary of the required services and is not intended to be all-inclusive). Oil/Water Separator and Septic Holding Tank maintenance and disposal services are required in support of a 12th Civil Engineering Squadron, at Randolph AFB, TX, Canyon Lake Recreation Area, TX and Sequin Auxillary Field, TX. Contractor shall be responsible for periodic maintenance which includes, but not limited to pump, clean and dispose of waste from all oil/water separators, lift stations and septic holding tanks. See Technical Exhibit 1. Included in this synopsis is a requirement for emergencies services which require at a maximum a two hour response time. Seeking one company to perform all requirements. BASIC TASKS: The contractor shall perform maintenance management on all tanks, traps and separators to ensure tanks, traps and separators comply with the federal, state, local environmental laws well as the San Antonio River Authority (SARA) regulations. Contractor personnel shall have all required licenses and permits necessary to perform services and disposal prior to the performance of any work on this contract. The contractor shall identify the individuals who are certified by the manufacturer of septic systems and will be completing the work on-site. Maintenance management consists of, but is not limited to, the contractor performing oversight of all traps, septic tanks and separators, providing recommendations to the Government on adjustments to pumping and cleaning frequencies, and disposing of waste as necessary to insure systems do not overflow and drainage lines are kept free flowing and clear of grease, oil, sand, waste and dirt. The contractor shall ensure all grates, covers; grills, etc are repositioned on the tanks and traps before departing the area. Contractor shall re-perform pumping, cleaning and clearing clogged lines and traps/tanks when work requirements have not been adequately accomplished. Re-performance shall be at no additional cost to the government. OIL/WATER SEPARATORS. Contractor shall pump all oil, oil residue and other waste from separators. Contractor shall ensure the separator is drained completely; inspect all parts for problems; wash and drain the separator and fill with clear water as required for the unique configuration of the separator. Contractor is responsible for transporting all materials from oil/water separators to a TCEQ registered and approved, off base oil recovery and storage facility. The contractor shall pay for all disposal costs and any required chemical analysis for disposal. The cleaning shall consist of removing the covers and thoroughly cleaning the inside of the grease interceptors to include baffles, inlet connection, outlet connection, walls, and any other unit components. The cleaning shall be accomplished by scraping, use of wire brush, chemicals and pumping out. At the completion of cleaning all surfaces to include walls, baffles, inlet connection and outlet connection shall be free of any grease buildup. Adequate ventilation shall be maintained at all times and precautions against the presence of explosive vapors shall be taken. Before performing quarterly maintenance, the contractor shall perform an initial hydro jet cleaning and one time pumping of all oil/water separators as listed on Technical exhibit 1. The contractor shall perform an analytical testing of all oil/water separators before the first pump and every 3 years after that to determine if the waste from all oil/water separators is a hazardous waste and is acceptable for transport and disposal at an off base oil recovery and storage facility. SEPTIC HOLDING TANKS. Contractor shall pump, and dispose all waste in accordance to with the federal, state, local, environmental laws. Contractor shall ensure all tanks are drained completely, and inspect all parts for problems. Cleaning shall include all surfaces of walls, baffles, inlet connection and outlet connection. The contractor shall provide scheduled maintenance to include adjusting and service mechanical, electrical and other applicable component parts to ensure proper function. Chlorine tablets will also be added to tanks to maintain a chlorine residue to what is required to maintain sewage holding tanks. The contractor shall provide a measuring device, either manual or meter to accurately determine the amount of waste removed from each tank area as determine by the QAP or CO. The job sites shall be kept neat and cleaned at all times, any spillage or leakage shall be washed down and disinfected to the satisfaction of the QAP. MONTHLY MAINTENANCE/CLEANING SCHEDULE. Contractor shall provide a monthly schedule showing the building number, dates and approximate times each trap, tank, and separator shall be serviced, to be approved by the government. The contractor will also be responsible for maintaining chlorine residual by adding a chlorine tablet designed for wastewater use only as stated in paragraph 10. The schedule shall be provided to the Government Quality Assurance Personal (QAP) with in five working days of the start of the month of performance. Technical Exhibit 1 OIL/WATER SEPARATORS LOCATIONSBLDG NO. SIZE (Gals) # OF SEPARATORSPUMPING FREQUENCY RANDOLPH161,5001QUARTERLY RANDOLPH471,500 1QUARTERLY RANDOLPH8931,5001QUARTERLY RANDOLPH898300 1QUARTERLY RANDOLPH1715001QUARTERLY RANDOLPH1751,0001QUARTERLY RANDOLPH13521,3001QUARTERLY SEPTIC HOLDING TANKS LOCATIONSBLDG NO. SIZE (Gals) TYPEPUMPING FREQUENCY RANDOLPH EBERLE PARK11803,000Holding tanks requires pumpingAnnual (Feb) RANDOLPH EBERLE PARK11855,000Holding tanks requires pumpingAnnual (Feb) RANDOLPH GOLF COURSE1303 500Holding tanks requires pumping Annual (Feb) RANDOLPH GOLF COURSE1330500Holding tanks requires pumping Annual (Feb) RANDOLPH POWER PRO12851000Holding tanks requires pumpingOn-call as required SEQUIN AUXILIRY4151000Holding tanks requires pumpingOn-call as required JACOB CREEK AREA39 2,250 Aerobic tanks drains to Leach Field Semi-annual (Feb, Aug) RV LOT AREALOT 11,200Dump stationOn-call as required JACOB’S CREEK BY BOAT DOCK AREA463,000Aerobic tanks drains to Leach Field Semi-annual (Feb, Aug) RANDOLPH REC AREA SCOUT’S CAMP AREA451,500Aerobic tanks drains to Leach FieldOn-call as required RANDOLPH REC AREA REST/BATH ROOM#24,000Aerobic tanks drains to Leach FieldAnnual (Feb) RANDOLPH REC AREA REST/BATH ROOM#21,250Aerobic tanks drains to Leach FieldOn-call as required RANDOLPH REC AREA RESTROOMS#21,000 overflowAerobic tanks drains to Leach FieldOn-call as needed RANDOLPH REC AREA RESTROOMS#6 6,000Aerobic tanks drains to Leach FieldOn-call as required RANDOLPH REC AREA RESTROOMS#61500Aerobic tanks drains to Leach FieldOn-call as required RANDOLPH REC AREA RESTROOMS#62,500 overflowAerobic tanks drains to Leach FieldSemi-annual (Feb, Aug) RANDOLPH REC AREA SHELTERS1 thru 8500Aerobic tanks drains to Leach FieldAnnual (Feb) RANDOLPH REC AREA SHELTERS1 thru 81,000Aerobic tanks drains to Leach FieldOn-call as required RANDOLPH AREA SHELTERS9 thru15500Aerobic tanks drains to Leach FieldAnnual (Feb) RANDOLPH AREA SHELTERS9 thru151,000Aerobic tanks drains to Leach FieldOn-call as required RANDOLPH AREA SHELTERS9 thru15500Aerobic tanks drains to Leach FieldAnnual (Feb) RANDOLPH AREA CABINS1 thru 61,000Aerobic tanks drains to Leach FieldOn-call as required RANDOLPH AREA CABINS1 thru 6500Aerobic tanks drains to Leach FieldAnnual (Feb) Central Contract Registration (CCR) is mandatory. The solicitation will be posted on FedBizOpps (http://www.fedbizopps.gov) electronically. All questions or comments shall be directed to Ms. Andrea D’Avignon, Contracting Specialist, by email at andrea.davignon@randolph.af.mil or (210) 652-5176. Do not contact personnel at Randolph AFB for information. It is prohibited to solicit employees of the United States Air Force during their duty hours.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=1c080f4a7dd6bf3ca758b50a42b8d8a7&tab=core&_cview=1)
 
Place of Performance
Address: Address: Randolph AFB, Canyon Lake Recreation Area, TX, and Seguin Auxillary Field, TX, Country: USA, San Antonio, Texas, 78150, United States
Zip Code: 78150
 
Record
SN01723157-W 20081224/081222215535-1c080f4a7dd6bf3ca758b50a42b8d8a7 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.