SOLICITATION NOTICE

Z -- Water Supply Flow Testing and Fire Hydrant Flow Testing in accordance with NFPA 25

Notice Date
1/13/2009
 
Notice Type
Presolicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of the Navy, Naval Facilities Engineering Command, NAVFAC MIDWEST PWD GREAT LAKES FEAD, N40083 NAVFAC MIDWEST PWD GREAT LAKES FEAD 201 Decatur Avenue Bldg 2016 Great Lakes, IL
 
ZIP Code
00000
 
Solicitation Number
N4008309Q3009
 
Response Due
2/13/2009
 
Archive Date
3/13/2009
 
Point of Contact
Marcus M. Sims 847.688.5395 x244 Belinda Trout847.688.5395 x248<br />
 
Small Business Set-Aside
Total Small Business
 
Description
The work includes furnishing all labor, transportation, supervision, material, and equipment and performing all operations in connection with the flushing and flow testing of approximately 600 fire hydrants located base wide. Contractor shall operate and flow test all fire hydrants in the system in accordance with AWWA standards (American Water Works Association Manual M-17, "Installation, Field Testing and Maintenance of Fire Hydrants".) and NFPA 25. The operation, location and flow test details of the hydrant tests will be noted and compiled in a report and shall be submitted to the government for a permanent record. The Contractor shall provide the proper number of personnel to insure the proper pressure drop required for testing standards. No Government personnel will be provided to assist the Contractor during flow testing and flushing of hydrants. Contractor shall meet with the Utility and Fire Department personnel to review the project guidelines and answer any questions on procedures. The Utility personnel shall also identify water pressure zones in the distribution system. If during operation, flow testing and flushing of the hydrants in the water distribution system, a failure of a valve or hydrant is noted, the Contractor shall contact the Government Representative as soon as practical. The Contractor shall use due care when operating Government water system features and will not be held responsible for failures during normal operation of hydrants for flushing and flow testing. Any damage to Government equipment or property due to negligence or improper operation by the Contractor will be repaired or replaced at the Contractor's expense as approved by the Project Manager or other Government Official.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=ffcd56a5b476fa7e559b77924b56cf64&tab=core&_cview=1)
 
Record
SN01731386-W 20090115/090113215237-ffcd56a5b476fa7e559b77924b56cf64 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.