SOLICITATION NOTICE
Q -- Equipment Operator/Service Technician Services
- Notice Date
- 1/21/2009
- Notice Type
- Presolicitation
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- Department of the Navy, Bureau of Medicine and Surgery, NMC San Diego, N00259 NAVAL MEDICAL CENTER MATERIAL MANAGEMENT 34800 Bob Wilson Drive, Suite # 8 San Diego, CA
- ZIP Code
- 00000
- Solicitation Number
- N0025909T0066
- Point of Contact
- Ann Session 619-532-8089
- Small Business Set-Aside
- N/A
- Description
- The proposed contract action is for commercial item, which the Naval Medical Center San Diego intends to solicit this requirement on a sole source basis to Alliant Healthcare Products under the authority of FAR 6.302. This is a combined solicitation/synopsis for commercial items, prepared in accordance with the format in FAR subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes only solicitation, quotations are being requested and a written solicitation will not be issued. The solicitation number, N00259-09-T-0059 is issued as a request for quotation (RFQ). The North American Industry Classification System (NAICS) Code for this acquisition is 339113; Size: 500. All interested bidders shall submit quotations electronically by email to ann.session@med.navy.mil or by facsimile at 619-532-5596, attention Ann Session. E-mail submissions are limited to 2MB. The submitter should confirm receipt of facsimile and email submissions. Quotations are due on or before 23 Jan 2008, 7:00AM Pacific Standard Time to be considered responsive. REQUEST ON SITE FULL MAINTENANCE CONTRACT TO BE INITIATED FOR THE LISTED GOVERNMENT-OWNED EQUIPMENT INCLUDING ALL PARTS, LABOR, TRANSPORTATION AND UNLIMITED MAINTENANCE CALLS, CORRECTIVE AND PREVENTIVE FOR THE PERIOD INDICATED. CLIN 0001 NMCSD Device: Integrated Operating Rooms 1 and 2 Stryker EquipmentOR#1 Serial Numbers: Switchpoint Infinity2 Control System 07E001468 Power Supply for Stryker Visum Surgical Light 302003021047065 Flat Screen Monitor Control Panel (1)MM7AVCL07090020 Flat Screen Monitor Control Panel (2)MM7AVCL07090094 Surgical Light (1)2019080020 Surgical Light (2)2019080031 In-Light Camera30-1541 Camera, Wall Mount07D001188OR#2 Serial Numbers: Switchpoint Infinity2 Control System07E001458 Power Supply for Stryker Visum Surgical Light3020030201057015 Flat Screen Monitor Control Panel (1)MM7AVCL07090008 Flat Screen Monitor Control Panel (2)MM7AVCL07090036 Surgical Light (1)2019080021 Surgical Light (2)2019080030 In-Light Camera30-1521 Camera, Wall Mount07D001128 OR#1 Serial Numbers: Spindle, Light/ Flat Panel030205703928030205703943 Spring Arm/Light011103753849 011105761606OR#2 Serial Numbers: Spindle, Light/ Flat Panel030205703930 030205703929 Spring Arm/Light011103753834011103753840OR#1 Serial Numbers: Spring Arm, Flat Panel01110475773201104757724 Boom Arm Articulating020307703360 Service Head 750 1928103(2) OR#2 Serial Numbers: Spring Arm, Flat Panel011104757760011104757731 Boom Arm Articulating020304702965 Service Head 7501928103(1) POP: 01 FEB 2009 to 30 SEP 2009 QTY 1 EA $______ CLIN 0002 NMCSD Device: Integrated Operating Rooms 7 and 8 Stryker Equipment OR#7 Serial Numbers: Switchpoint Infinity 2 Control System07I000338 Power Suply for Stryker Visum Surgical Light2020220140 Flat Screen Monitor Control Panel (1)MM7AVCL07120131 Flat Screen Monitor Control Panel (2)MM7AVCL07270786 Surgical Light (1)2020220120 Surgical Light (2)2025040030 In-Light Camera30-1575 Camera, Wall Mount07I000428OR#8 Serial Numbers: Switchpoint Infinity 2 Control System07I000328 Power Suply for Stryker Visum Surgical Light2020220040 Flat Screen Monitor Control Panel (1)MM7AVCL07270033 Flat Screen Monitor Control Panel (2)MM7AVCL07270103 Surgical Light (1)2020220020 Surgical Light (2)2020220030 In-Light Camera30-1570 Camera, Wall Mount07I000398 POP: 01 FEB 2009 to 30 SEP 2009 QTY 1 EA $______ CLIN 0003 NMCSD Device: Integrated Operating Rooms 12 and 13 Stryker Equipment OR#12 Serial Numbers: Switchpoint Infinity2 Control System07L001968 Power supply for Stryker Visum Surgical Light2020230140Flat Screen Monitor Control Panel (1)MM7AVICL07380116Flat Screen Monitor Control Panel (2)MM7AVICL07450132Surgical Light (1)2020230130Surgical Light (2)2020230120In-Light Camera30-1632Camera, Wall Mount07L001708 OR#13 Serial Numbers: Switchpoint Infinity2 Control System07L001978 Power supply for Stryker Visum Surgical Light2020230040Flat Screen Monitor Control Panel (1)M1085SG5490098Flat Screen Monitor Control Panel (2)MM7AVICL07380038Surgical Light (1)2020230020Surgical Light (2)2020230030In-Light Camera30-1633Camera, Wall Mount07L001048 POP: 01 FEB 2009 TO 30 SEP 2009 QTY 1 EA $______ CLIN 0004 NMCSD Device: Integrated Operating Rooms 5 and 6 Stryker Equipment OR #5 Serial Numbers: Switchpoint Infinity 2 Control System08D001558 Power Supply for Stryker Visum Surgical Light2028880380 Flat Screen Monitor Control Panel (1) MM7AVCL07270182 Surgical Light (1)2028870020 Surgical Light (2)2028870270 In-Light Camera30-1706 Camera, Wall Mount08D003698 OR #6 Serial Numbers: Switchpoint Infinity 2 Control System08D001548 Power Supply for Stryker Visum Surgical Light2028870110 Flat Screen Monitor Control Panel (1) M1085SG6110078 Surgical Light (1)2028870260 Surgical Light (2)2028870100 In-Light Camera30-1709 Camera, Wall Mount08D003708POP: 01 JUN 2009 TO 30 SEP 2009 QTY 1 EA $______ CLIN 0005 NMCSD Device: Integrated Operating Rooms 14 and 15 Stryker EquipmentOR# 14 Serial Numbers: Switchpoint Infinity 2 Control System08F003928 Power Supply for Stryker Visum Surgical Light (1)2028880030 Flat Screen Monitor Control Panel (1)MM7AV1CL07500008Surgical Light (1)2028880470Surgical Light (2)2028890020In-Light Camera30-1802Camera, Wall Mount08F003568 OR# 15 Serial Numbers: Switchpoint Infinity 2 Control System08F003938Power Supply for Stryker Visum Surgical Light (1)2028890110Power Supply for Stryker Visum Surgical Light (2)2028890190 Flat Screen Monitor Control Panel (1)MM7AV1CL07500014Surgical Light (1)2028880370Surgical Light (2)2028890180 Surgical Light (3)2028890100In-Light Camera30-1801Camera, Wall Mount08F003578POP: 01 AUG 2009 TO 30 SEP 2009 QTY 1 EA $______ Under the authority of FAR 13.106-1(b), sole source justification is based on FUJIFILM MEDICAL SYSTEMS U.S.A. INC. being the OEM of the system requiring the service maintanance, which includes software and hardware parts that are proprietary and can only be serviced by the OEM. Contractor must be registered to the Central Contractor Registration (CCR) prior to award. The website address for CCR registration is www.ccr.gov Contractor MUST complete FAR 52.212-3, Offeror Representations and Certifications - Commercial Items, when submitting a proposal. The website address is http://www.arnet.gov.SERVICE ADDRESS: Naval Medical Center, Radiology Department, 34800 Bob Wilson Drive, San Diego, CA. 92134 Tricar Oupatient Clinic, 8808 Balboa Avenue, San Diego, CA. 92134 Tricar Outpatient Clinic, 644 Naples Street, Chula Vista, CA. 91911 The solicitation document and incorporated provisions and clauses are those in effect through FAC 2005-27. This acquisition incorporates the following FAR clauses: 52.204-7 Central Contractor Registration (APR 2008)52.212-1 Instruction to Offerors-Commercial Item (APR 2008) 52.212-3 Offeror Representations and Certification--Commercial Items (MAY 2008) 52.212-4 Contract Terms and Conditions--Commercial Items (FEB 2007)52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders--Commercial Items (MAR 2007)52.222-3 Convict Labor (JUN 2007) 52.222-19 Child Labor -- Cooperation with Authorities and Remedies (JAN 2006) 52.222-21 Prohibition Of Segregated Facilities (FEB 1999)52.222-26 Equal Opportunity (MAR 2002) 52.222-36 Affirmative Action For Workers With Disabilities (JUN 1998) 52.225-13 Restrictions on Certain Foreign Purchases (FEB 2006)52.232-18 Availability of Funds (APR 1984)52.232-36 Payment by Third Party (MAY 1999)52.252-2 Clauses Incorporated By Reference (FEB 1998) 252.212-7001 Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items (APR 2007) 252-225-7000 Buy American Act - Balance of Payment Program Certificate (JUN 2005)252-225-7001 Buy American Act and Balance of Payments Program (JUN 2005) 252.225-7002 Qualifying Country Sources As Subcontractors (APR 2003) 252.232-7003 Electronic Submission of Payment Requests (MAR 2007) 52.222-48 Exemption from Application of the Service Contract Act to Contracts for Maintenance, Calibration, or Repair of Certain Equipment Certification. (NOV 2007) All responsible sources may submit a quotation which shall be considered by the agency.
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=8ba7c1801a5b239ad86a7e8a0e8d8300&tab=core&_cview=1)
- Record
- SN01735621-W 20090123/090121215625-13e15eabdfd9597d1f9c1983b219a99c (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |