SOLICITATION NOTICE
99 -- Fume Hood
- Notice Date
- 2/10/2009
- Notice Type
- Modification/Amendment
- Contracting Office
- Environmental Protection Agency, Office of Acquisition Management, EPA/Headquarters, Environmental Protection Agency, Emergency Response Service Center, 1200 Pennsylvania Ave., Nw, Washington, DC 20460
- ZIP Code
- 20460
- Solicitation Number
- RFQ-DC-09-00110
- Response Due
- 2/13/2009
- Archive Date
- 3/13/2009
- Point of Contact
- Point of Contact, Micole Cheatham, Purchasing Agent, Phone (202) 564-7647<br />
- Small Business Set-Aside
- N/A
- Description
- NAICS Code: 336212 The U.S. Environmental Protection Agency (EPA), in accordance with Federal Acquistion Regulation (FAR) Part 13, Simplified Acquisition Procedures, intends to award a purchase order for the procurement and installation of a Fume hood for the Cargo Trailer at EPA'sResearch Triangle Park Facility, North Carolina. This service is necessary to complete the Cargo Trailer. The hood specifications are the following: Labconco #3030000 "Fiberglass 30"Standard Model Fume Hood with Blower and Guardian Air Flow System and Epoxy Flat Work Surface Statement of work for fume hood installation ?Procure Labconco #3030000 Fiberglass 30? standard model fume hood with blower and Guardian air flow system and epoxy flat work surface. The specifications follow:Item Dimensions: 30.00"w x 30.16"d x 48.00"hElectrical Specification: 115 volts, 60 Hz, DomesticProduct Subcategory: General ChemistryStyle: BenchtopNominal Width: 30"Electrical Requirements: DomesticBlower Requirements: Integral blower and switch includedLighting: vapor-proof incandescentCompliance: SEFA 1-2002, NFPA 45-2000, ASTM E84-01, ASHRAE 110-95, ANSI Z9.5-1993, UL 3101-1/61010-1, CAN/CSA C22.2 No. 1010.1, UL 1805, CE Conformity Marking (230 volt models)Air Usage/Static Pressure with Sash Full Open: At 100 fpm, exhausts 310 CFM at 0.12" H2O maximum external static pressure.?Professionally wire electrical requirements (according to all appropriate codes) for fume hood at customer designated location without any damage to existing electrical or interior structural work.?Professionally install exhaust through the roof (according to all appropriate codes) of the trailer at customer designated location without any damage to existing interior and/or exterior structural work.?Ensure that hood functions according to the above specifications upon completion of the installation.?Professional installation must be completed within 3 days to ensure no delay with laboratory delivery.?Work must be guaranteed for 1 year. The National American Industry Classification System (NAICS) code for this requirement is: 336212 Please submit your quotes via email to the US Environmental Agency, c/o Mr. Micole Cheatham at cheatham.micole@epa.gov by 02/13/2009 4pm.
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=42c1b459fdb358a08ea1e506cc300536&tab=core&_cview=1)
- Record
- SN01747926-W 20090212/090210220559-42c1b459fdb358a08ea1e506cc300536 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |