Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 13, 2009 FBO #2664
SOURCES SOUGHT

59 -- GARRISON MAJOR REHABILITATION SF-6 HIGH VOLTAGE BREAKERS, GARRISON POWER PLANT, RIVERDALE, NORTH DAKOTA.

Notice Date
3/11/2009
 
Notice Type
Sources Sought
 
NAICS
335313 — Switchgear and Switchboard Apparatus Manufacturing
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, U.S. Army Engineer District, Omaha, US Army Corps of Engineer - Omaha District, 1616 Capital Ave, Omaha, NE 68102-4901
 
ZIP Code
68102-4901
 
Solicitation Number
W9128F-09-S-J002
 
Response Due
3/25/2009
 
Archive Date
5/24/2009
 
Point of Contact
Janice Cook, 402/995-2052<br />
 
Small Business Set-Aside
N/A
 
Description
The Omaha District, US Army Corps of Engineers is seeking qualified members of the Small Businesses Community (Small Businesses (SB) Small Disabled Small Business (SDB) Woman Owned Small Businesses (WOSB) Service Disabled Veteran Owned SB (SDVOSB) Historically Underutilized Business Zone (HubZones) and Section 8(a) Participants) or small business-led teams, and small business joint ventures and Other than Small (OTS) concerns that qualify under the North American Industry Classification System (NAICS) Code 335313 Switchgear and Switchboard Apparatus Manufacturing for the following requirement located at the Garrison Power Plant, Riverdale, North Dakota. The principal components of the work to be performed would be delivery and set for storage SF-6 type gas circuit 230 kV and 115 kV breakers as follows: 230 kV circuit breakers: Maximum voltage, 245 kV; continuous current, 2000/3000 amperes; short-circuit current, 40 kA; interrupting time 50 ms; closing and latching current 104 kA peak. 115 kV circuit breakers: Maximum voltage, 123 kV; continuous current, 2000/3000 amperes; short-circuit current, 63 kA; interrupting time 50 ms; closing and latching current 164 kA peak. Contractor shall deliver the breakers to the site and place for storage. All equipment shall be supplied FOB to the location(s) indicated in the previous paragraph. This announcement is part of our market research, and your responses are sought to identify sources that have the knowledge, skills, and capability to perform the work. Interested contractors, including small businesses and small business-led teams that qualify under NAICS Codes 335313 are hereby invited to submit a response to the market survey to demonstrate their technical, managerial and business capability to provide the requested services. It is anticipated that the Government will issue a firm fixed price. The estimated price range for this effort is between (See FAR Part 36.304) $4 - $5 mil. The estimated performance period is December 2010. THIS SOURCES SOUGHT NOTICE DOES NOT CONSTITUTE A REQUEST FOR A FORMAL PROPOSAL. This notice is provided as information to the marketplace and is an invitation for an expression of interest and demonstration of small business capability to perform the anticipated work. The Government will not pay for the provision of any information, nor will it compensate any respondents for the development of such information. All interested, capable, qualified and responsive contractors are encouraged to reply to this market survey request. Interested Contractors must furnish the following information: General Information 1.What is your company name, address, point of contact, phone number, and e-mail address? 2.What is your business size? 3.Do you have any corporate affiliations? If so, please identify. 4.Are you interested in participating as a leader or member of a small business-led team? a.If so, specify what type of team arrangement (joint venture, prime contractor/subcontractor, other). b.Provide a list of potential team members and associated disciplines, if known. c.Describe your current/anticipated team management structure. Past Performance Information 5.Please provide any past performance information for the previous 3 years that clearly demonstrates familiarity and experience with the requirements. For each project, include the following information: a.Size, term, and complexity of job; b.Information on your role as either a prime contractor or subcontractor; and c.Point of contact (POC) at the agency or prime contractors organization to verify contact information, including name, address, e-mail address, telephone number, and information on the specific tasks you performed on the project. 6.Please provide a brief description of your experience either managing a team or acting as a member of a team of businesses working on large, complex projects. Provide POCs (name, address, e-mail address, and telephone number) that can verify this experience. Responses to this announcement may be sent electronically to Jan Cook at jan.m.cook@usace.army.mil to arrive no later than 2:00 p.m. (CST) 25 March 2009. Responses should be limited to no more than 10 pages. If you are unable to send the information via e-mail, you may mail it to the address below. All mailed documents must include a return address on the outside envelope to be accepted. US ARMY CORPS OF ENGINEERS CONTRACTING DIVISION CECT-NWO ATTN: JAN COOK 1616 CAPITOL AVENUE OMAHA, NE 68102-4901 Questions should be forwarded to Jan Cook at 402-995-2052 or via e-mail at the address above. PLEASE BE ADVISED THAT ALL INFORMATION SUBMITTED WILL BE CONSIDERED PROCUREMENT SENSITIVE.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=b41748d093f111728b27d8d6e2c71a1d&tab=core&_cview=1)
 
Place of Performance
Address: US Army Corps of Engineer - Omaha District 1616 Capital Ave, Omaha NE<br />
Zip Code: 68102-4901<br />
 
Record
SN01767342-W 20090313/090311220741-b41748d093f111728b27d8d6e2c71a1d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers