SOLICITATION NOTICE
Z -- Design/Build, Installation of Water Meters & Repair of Water Mains
- Notice Date
- 3/17/2009
- Notice Type
- Presolicitation
- NAICS
- 237110
— Water and Sewer Line and Related Structures Construction
- Contracting Office
- Department of the Air Force, Air Education and Training Command, Lackland AFB - 37th Contracting Squadron, 1655 Selfridge Avenue, Lackland AFB, Texas, 78236-5253
- ZIP Code
- 78236-5253
- Solicitation Number
- FA3047-09-R-0015
- Point of Contact
- Michael A Corrigan,, Phone: 210-671-1736, Gerardo Villarreal,, Phone: 210-671-5146
- E-Mail Address
-
michael.corrigan@lackland.af.mil, gerardo.villarreal@lackland.af.mil
- Small Business Set-Aside
- N/A
- Description
- In compliance with the transparency and accountability requirements associated with the supplemental appropriations provided by the American Recovery and Re-investment Act of 2009, Pub.L. 111-5, the Government posts this presolicitation notice of intent to issue an 8(a) Sole Source Request for Proposal to HCR Construction Inc., 1605 Chattahoochee Run Dr. Suwanee, GA 30024. The Project description is as follows: PROJECT SCOPE Contractor shall provide a complete design (Title I Services A & B) for the replacement of approximately 25000 linear feet of water lines in the 7000 area and for the installation of water meters at approximately 60 facilities base wide. All work shall be in conformance with the drawings and specifications and with applicable codes, standards and regulations and shall include the furnishing of all materials, labor, plant, tools, equipment, and services necessary and incidental thereto. The work required to be performed by the contractor shall consist of but is not limited to the following principal items: --DESIGN Contractor shall provide a complete design for the replacement of water mains and the installation of water meters. The design shall consisting of plans, specifications, design analysis and cost estimate. A design package shall be submitted at the 65% and 95% stages of design. The 65% design submittal will be reviewed and accepted by the government prior to continuation to 95%. Construction will commence upon acceptance of the 95% design submittal. --WATER MAIN REPLACEMENT Existing water mains shall be abandoned in place. Contractor shall install approximately 12,500 linear feet of 6” AWWA C900 PVC pipe and approximately 12,500 linear feet of 8” AWWA C900 PVC pipe in the area bordered approximately by Treumper, Carswell and Tinker streets and as shown on project location map. Contractor shall demo and replace approximately 40 existing fire hydrants and associated fire hydrant valves. Contractor shall replace approximately 70 existing main line isolation valves. Contractor shall demo existing valve boxes. Contractor shall install additional isolation valves and fire hydrants as necessary to meet applicable design criteria. All valves and fire hydrants shall be right handed (right = closed). Contractor shall relocate approximately 50 service lines from existing mains to new mains. Contractor shall restore excavated areas to existing conditions. Contractor shall provide all materials, labor, plant, tools equipment and services necessary to provide a complete and fully functioning system in compliance with design drawings, specifications and submittal register and in conformance with all applicable codes, standards and regulations.
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=f44a9202c3de514976717882cdc36192&tab=core&_cview=1)
- Place of Performance
- Address: 37 Contracting Sq, San Antonio, Texas, 78236, United States
- Zip Code: 78236
- Zip Code: 78236
- Record
- SN01770834-W 20090319/090317215809-f44a9202c3de514976717882cdc36192 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |