Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 04, 2009 FBO #2686
SOURCES SOUGHT

Y -- Renovation Building 448 Naval Base New London, Groton, CT

Notice Date
4/2/2009
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
N40085 NAVFAC MID-ATLANTIC Naval Facilities Engineering Command, Mid-Atlantic Code AQ, 9742 Maryland Avenue Norfolk, VA
 
ZIP Code
00000
 
Solicitation Number
N4008509R7041
 
Response Due
4/10/2009
 
Archive Date
5/10/2009
 
Point of Contact
Larry Scheible(757)444-0684
 
Small Business Set-Aside
N/A
 
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. THERE WILL NOT BE A SOLICITATION, SPECIFICATIONS, OR DRAWINGS AVAILABLE AT THIS TIME.The Naval Facilities Engineering Command, Mid-Atlantic is seeking eligible small business firms capable of performing construction services for the following project for Renovation Building 448 Naval Base New London, Groton, CT Description of proposed project: Renovation Building 448 Naval Base New London, Groton, CT The contract will abate an environmental hazard in Building 448 caused by the asbestos containing spray-on fireproofing. The project also repairs or replaces components of the HVAC system, installs a fire sprinkler system, replaces suspended ceilings and light fixtures removed during the asbestos abatement, installation of fire sprinklers, building roof replacement and interior painting. This project involves the abatement of asbestos containing spray-on fireproofing materials that have been applied to structural steel. Heating Ventilation and Air Conditioning (HVAC) components including air handling units, coils, piping, ducts, controls, and circulating pumps will be replaced or repaired. A fire sprinkler system will be installed in the section of the building that was constructed in 1971. The entire building roof will be replaced. Suspended ceilings and light fixtures required to be removed for asbestos abatement shall be replaced and interior painting performed. The project may also include: interior space renovations, interior demolition, electrical system upgrades, installation of fire alarm systems, and installation of furniture, fixtures and equipment (FF&E).Building 448 is a four story building constructed in 1971. A three story addition was added in 1979 increasing the building space to 61,745 sf. The structural steel in the original four story section of the building was coated with a sprayed on fire proofing material which contained asbestos. When the addition to building 448 was built in 1979 it included a fire sprinkler system.Although predominately intact and undamaged, the asbestos fire proofing material does release enough material to accumulate fibrous asbestos dust on the suspended ceiling system. Access to spaces above the suspended ceiling is restricted due to the potential to encounter asbestos containing materials. Approximately 73% of the HVAC system is comprised of original components from 1971 and1979. These HVAC components are either at the end of their service life. A 2002 HVAC study recommended the replacement of: three major air handling units, chilled water pumps, piping, controls, air cooled chiller, ductwork, high velocity reheat boxes, and electrical wiring. The built up roofing is missing aggregate in sections which exposes the roofing surface. Sections of the roof and flashing have blisters, holes and tears which allow water penetration. Water from roof leaks has damaged ceiling tiles. Roofing materials appear to be original from initial construction. The roofing materials ! may contain asbestos. An asbestos survey of the building is underway.The total project price magnitude is between $5,000,000.00 and $10,000,000.00. All Service Disabled Veteran (SDV) small businesses, certified HUBZone small businesses, certified 8(a) small businesses, and other certified small businesses are encouraged to respond. Large Business submittals will not be considered. Upon review of industry response to this Sources Sought Synopsis, the Government will determine whether a set-aside acquisition in lieu of full and open competition is in the Government's best interest. This office anticipates award of a contract for these services prior to 30 September 2009. The appropriate NAICS code for this procurement is 236220. THIS SYNOPSIS IS NOT A REQUEST FOR PROPOSAL. This synopsis is a market research tool being used to determine the availability and adequacy of potential small business sources prior to determining the method of acquisition and ultimate issuance of an award. The Government is not obligated to and will not pay for any information received from the potential sources as a result of this synopsis. It is requested that interested small businesses submit to the contracting officer a brief capabilities statement package (no more than 10 pages in length, single spaced, 12 point font minimum) demonstrating ability to perform the requested services. PAGES IN EXCESS OF THE FIRST 10 PAGES WILL NOT BE CONSIDERED. The documentation shall address the following: (1) Relevant Experience to include experience in performing efforts of similar value, size, and scope within the last five (5) years including contract number, indication of whether your firm acted as a prime or subcontractor, contract value, Government/Agency point of contact and current telephone number, and a brief description of how the contract relates to the technical services described herein. Ensure this relevant experience includes examples of all work described in the Building 448 Naval Base New London, Groton, CT project above. Provide a maximum of 5 projects only. Projects over 5 will not be reviewed/considered.(2) Company Profile to include:1. Number of employees.2. Office location(s).3. Available bonding capacity per contract.4. DUNS number.5. CAGE Code.6. A statement regarding small business designation and status.This information shall be included in a single cover sheet and included as the first page of your submittal. Do not submit Letters of Commendation, letters from bonding agents, resumes of personnel, or anything not requested above. Your submittal should not be placed in any document protectors, bindings, or folders. RESPONSES ARE DUE NLT 10 April 2009, NLT 2:00 PM EST. LATE RESPONSES WILL NOT BE ACCEPTED. Electronic submission of the statement of capabilities package will not be accepted. The package shall be sent, by mail or hand carried, to: Commander Naval Facilities Engineering Command, Mid-Atlantic, NE IPT9742 Maryland Avenue (Building Z-144, 2nd Floor, Room 214)Norfolk, Virginia 23511-3689Attn: Larry Scheible Electronic submission of the statement of capabilities package will not be accepted. Questions or comments regarding this notice may be addressed to Larry Scheible either by email at Lawrence.scheible@navy.mil or phone 757-444-0684.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=f014e2fae10561eb593ffa985dd9461e&tab=core&_cview=1)
 
Record
SN01784677-W 20090404/090402221719-f014e2fae10561eb593ffa985dd9461e (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.