Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 30, 2009 FBO #2712
SOLICITATION NOTICE

58 -- 250 WATT FM TRANSMITTER SYSTEM

Notice Date
4/28/2009
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334220 — Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing
 
Contracting Office
Other Defense Agencies, OSD - Public Affairs for Internal Communication, Defense Media Activity, 23755 Z Street, Riverside, California, 92518-2031, United States
 
ZIP Code
92518-2031
 
Solicitation Number
HQ002890708600
 
Archive Date
5/28/2009
 
Point of Contact
Susan M. Madrid,, Phone: 951-413-2371
 
E-Mail Address
susan.madrid@dodmedia.osd.mil
 
Small Business Set-Aside
Total Small Business
 
Description
Combined Synopsis/Solicitation HQ002890708600 This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; a written solicitation will not be issued. Solicitation/synopsis reference number HQ002890708600 is being issued as a Request for Quotations (RFQ) and incorporates the following with the word “quoter” substituted for “offeror”. Provisions and clauses are those in effect through Federal Acquisition Circular 2005-32 effective 31 Mar 2009 and DFARS Change Notice 20090115. (1) FAR 52.212-1 (Instructions to Offerors – Commercial Items) (JUN 2008): (a) Re para (a): NAICS 334220; small business size standard is 750 employees. (b) Note that para (k) requires quoter to be registered with the Central Contractor Registration (CCR) database at time of contract award and throughout the performance period. (2) FAR 52.212-2 (Evaluation – Commercial Items) (JAN 1999) with the following insertion in para (a) “lowest priced technically acceptable quote with acceptable past performance.” Technical evaluation will be whether quoted items satisfy all required technical specifications contained in CLIN 0001 below. Technical specifications for quoted items MUST accompany the offeror’s bid submittal. (3) QUOTATIONS MUST BE RECEIVED NOT LATER THAN 2:00 PM PACIFIC TIME 13 MAY 2009 IN ORDER TO BE CONSIDERED. Quote submissions may be e-mailed to susan.madrid@dma.mil or sent via fax to (951) 413-2432. Due to technical issues, email and fax may not result in your proposal arriving before the cut-off time, please allow extra time if you’re sending your quote via electronic means. (4) Quotations must include completed copy of provision at FAR 52.212-3 (Offeror Representations and Certifications – Commercial Items) (FEB 2009) with Alt 1 (APR 2002) or indication that reps and certs are located on the Online Representations and Certifications Application (ORCA) website. CLIN 0001 – Name: 250 Watt FM Transmitter System QTY: 1 Each Unit Price: Total Amount: The FM transmitter system is required to be a Main/Alternate type configuration with automatic changeover. Main/alternate transmitter and changeover switch must be rack mountable, rack included. System must include: - dial up remote / computer interface: for control and monitoring with alarm call out feature - manufacturer recommended spare parts kit to include spare power supply and spare RF amplifier assembly - 500 watt dummy load - 10 each, 10 feet pieces of RG393 - 2 each N connectors The following are technical specifications for the transmitter system: GENERAL RF Power Output: 25-250W Output Impedance: 50 ohms nominal VSWR: Rated power into 1.5:1 VSWR. Open and short circuit protected at all phase angles. Frequency Range: 87.5MHz to 108MHz; 100kHz increments, 10kHz when specified Frequency Stability: Internal TCXO: +/-300Hz, -10°C to +50°C External Output: +/- accuracy of reference source Audio Inputs: AES (wire & optical), L&R analog, composite, SCA/RBDS/RDS external generator input, SCA audio inputs (2); two internal SCA generators, internal RBDS/RDS generator Modulation Type: Direct-to-channel digitally generated FM (no analog up-conversion); FM only, HD Radio only, or HD Radio + FM Modulation Capability: Up to 300kHz Asynchronous AM S/N Ratio: 80dB below rated power reference carrier with 100% AM modulation at 400Hz, 75 lsec-de-emphasis with no FM modulation present Synchronous AM S/N Ratio: 60dB below rated power reference carrier with 100% AM modulation at 400Hz, 75 lsec-de-emphasis with FM modulation +/- 75kHz at 400Hz Spurious and Harmonic: 85dB or better; low pass filter standard AC Input: 90 to 264VAC; 47-63Hz Power Factor: 0.98 or better Surge Protection: Tested with IEEE C62.41-1991 recommended waveforms for location category B3 and IEC 801-4 standard waveforms for severity level 4 Regulatory: FCC; DOC; CE; CCIR; IEC 215 Safety ENVIRONMENTAL Temperature Range: -10°C to +50°C Altitude: 10,000 ft (3048 m) Humidity: 95% maximum, non-condensing STEREO PERFORMANCE Operational Modes: Stereo, mono (L+R), L only, R only Input Level: AES: -2dBfs for 100% modulation; 16-24 bits (32, 44.1, 48 or 96kHz typical rates for AES/EBU devices) L&R: +10dBm for 100% modulation into 600 ohms Impedance: AES: 110 ohms balanced L&R: 600 ohms or 10k selectable; balanced Connector: AES: Wire-XLR, Optical-Toshiba (TosLink) L&R: XLR Amplitude Response: +/- 0.5dB, 20Hz to 15kHz THD + Noise: 0.03% or better IMD Distortion: 0.03% or better S/N Ratio: 85dB or better below 100% modulation @ 400Hz Stereo Separation: 70dB, 20Hz to 15kHz Linear Crosstalk: 70dB below 100% modulation; 20Hz to 15kHz; main to sub and sub to main Pilot Stability: +/- 0.3Hz, 0°C to 50°C Audio Overshoot: 2dB max 38,57,76 and 95kHz Suppression: 80dB below 100% modulation COMPOSITE PERFORMANCE Input Level: 3.5V p-p for 100% modulation into 10k ohms Impedance: Balanced: 10k ohms or 50 ohms selectable Unbalanced: 10k ohms Connector: Balanced: BNC Unbalanced: BNC Amplitude Response: +/- 0.01dB; 20Hz to 53kHz; 0.1dB; 53kHz to 99kHz Phase Response: +/- 0.1° from linear phase; 53kHz to 100kHz THD + Noise: 0.005% or less IMD Distortion: 0.005% or less FM S/N Ratio: 90dB below 100% modulation @ 400Hz MONO PERFORMANCE Operational Modes: Mono (L+R), L only, R only Input Level: 3.5V p-p for 100% modulation into 600 ohms Impedance: 600 ohms or 10k ohms selectable Connector: XLR Amplitude Response: +/- 5dB; 20Hz to 15kHz THD + Noise: 0.05% or less; 20Hz to 15kHz IMD Distortion: 0.05% or less; 20Hz to 15kHz FM S/N Ratio: 90dB below 100% modulation @ 400Hz SCA 1&2 PERFORMANCE (INTERNAL) Operational Modes: Mono (L+R), L only, R only Input Level: 3.5V p-p for 100% modulation into 600 ohms Impedance: 600 ohms or 10k ohms selectable Connector: XLR Amplitude Response: +/- 0.5dB; 20Hz to 7kHz THD + Noise: 0.05% or less; 20Hz to 15kHz IMD Distortion: 0.05% or less; 20Hz to 15kHz FM S/N Ratio: 90dB below 100% modulation @ 400Hz RBDS/RDS PERFORMANCE (INTERNAL) Frequency: 57kHz Injection Level: 2 to 15%; software programmable SCA/RBDS/RDS (EXTERNAL) Input Level: 3.5V p-p for 10% deviation Impedance: 10k ohms unbalanced Connector: BNC Amplitude Response: +/- 0.5dB; 20Hz to 100kHz 19kHz Output: 19kHz synchronization clock for external RBDS/RDS operation 2.5V p-p into 50 ohms PHYSICAL Height: 7 inches Width: 19" EIA rack mountable Depth: No rear rails required - fits into 24" deep rack Airflow: Intake and exhaust through back of unit Weight: 38 lbs. unpacked SHIPPING ADDRESS is: DMA CRP BELVOIR ATTN: MR. JOSE VILLAZON 5921 16TH STREET, BLDG. 190 FT. BELVOIR, VA 22060 All items must be quoted FOB Destination. It is the responsibility of all interested quoters to review this site frequently for any updates/amendments that may occur during the solicitation process. The response date cited above does not obligate the Government to award a contract nor does it obligate the Government to pay for any proposal preparation costs. The Government reserves the right to cancel this procurement/solicitation either before or after the solicitation closing date, with no obligation to the quoter by the Government. All prospective contractors must be registered in the Central Contractor Registration (CCR) in order to be eligible for contract award. For registration, go to http://www.ccr.gov/ and follow the instructions. The Government will issue an order to the responsible quoter, with acceptable past performance, submitting the lowest priced technically acceptable quotation. This order will include the following referenced clauses which may be accessed electronically at www.arnet.gov: FAR 52.204-9 (Personal Identity Verification of Contractor Personnel (SEP 2007) FAR 52.212-4 (Contract Terms and Conditions-Commercial Items) (FEB 2007) FAR 52.212-5 (Contract Terms and Conditions Required to Implement Statues or Executive Orders-Commercial Items) (APR 2008) FAR 52.219-8 (Utilization of Small Business Concerns and Small Disadvantage Business Concerns) (MAY 2004) FAR 52.232-33 (Payment by Electronic Funds-Central Contractor Registration) (OCT 2003) DFARS 252.204-7004, Alt A (Required Central Contractor Registration (CCR) (SEP 2007) DFARS 252.232-7003 (Electronic Submission of Payment Request) (MAR 2008) DFARS 252.246-7000 (Material Inspection and Receiving Report) (APR 2008) Additional FAR and DFARS clauses required by the regulations will be included. Local DMC clauses, 52.0100-4028 (Contract Contact Information)(DMC) (JUN 2005) and 52.0100-4094 (Marking Instructions for All Items to Include Drop Ship and Direct Shipment) (JUN 2006), will be included.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=373ce11291d80e136ddfbc6aadcb835a&tab=core&_cview=1)
 
Place of Performance
Address: 23755 Z. STREET, RIVERSIDE, California, 92518, United States
Zip Code: 92518
 
Record
SN01803808-W 20090430/090428221255-373ce11291d80e136ddfbc6aadcb835a (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.