SOLICITATION NOTICE

Y -- Replace Hangar Deck Heating System Bldg 144.

Notice Date
5/1/2009
 
Notice Type
Presolicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of the Navy, Naval Facilities Engineering Command, NAVFAC Washington, ROICC Pax River, N40080 NAVFAC WASHINGTON, NAS PATUXENT RIVER/FEAD 22445 Peary Road Bldg 504 Patuxent River, MD
 
ZIP Code
00000
 
Solicitation Number
N400801072769
 
Response Due
6/1/2009
 
Archive Date
6/16/2009
 
Point of Contact
Cynthia Z. Wright 301-757-4911 Barbara A. Thompson 301-757-4918<br />
 
Small Business Set-Aside
8a Competitive
 
Description
Project Description: Base bid consists of replacing hangar deck heating system Bldg 144. Option 1 consists of recovery heating. Option 2 consists of windows and door for Boiler Bldg 144A. The exact locations are specified on the drawing. Base bid: The intent of this Design/Build project is to replace the existing Heating System on the deck of hangar 144. This includes but is not limited to: Demolition of the existing steam heating system.Design, provide and install a fully functional Steady State Heating System on the deck of hangar 144.Identification of possible asbestos material on the steam line insulation, windows mastic, boilers and lead paint for penetration to the hangar, windows and mechanical equipment. Option 1: In addition to Steady State Heating System required by the base contract, design and provide a Recovery Heating System for the deck of Hangar 144. Option 2 description: Replace eight (8), 3' X 8' windows at the boiler building 144A andan exterior metal door. The interior wall and ceiling surfaces of Hangar 144 Deck are RF shielded. The RF shield is a steel mesh that is soldered with silver solder. Shield penetrations must be kept to an absolute minimum - KTR should use theprevious holes left when the old heating systems piping is removed, if at all possible. New piping should be secured to the RF shield in like manner as was the old piping before removal. Cover any opening created by thedemolition with the same shield material. Conduct survey to identify hazardous materials (HAZMAT) suspected to exist, such as lead paint, asbestos pipe & boiler insulation, and asbestos mastic on windows. As part of the proposal, submit unit costs for abatement of those materials. A modification to the contract is planned based on the survey results and the unit pricing provided.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=200e4ce8e1a6c0cf31f87f6c912c1de2&tab=core&_cview=1)
 
Place of Performance
Address: NAVFACENGCOM-WASH22445 PEARY RD, BLDG 504 ATTN: ACQUISITIONS, PATUXENT RIVER, MD<br />
Zip Code: 20670<br />
 
Record
SN01807429-W 20090503/090501222442-200e4ce8e1a6c0cf31f87f6c912c1de2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.