Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 30, 2009 FBO #2742
SOLICITATION NOTICE

66 -- Modification of UV Entry System

Notice Date
5/28/2009
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of the Army, Army Contracting Agency, North Region, ACA, Dugway Proving Ground, Division of Contracting, Bldg 5330 Valdez Circle, Dugway, Utah, 84022-5000
 
ZIP Code
84022-5000
 
Solicitation Number
W911S6-09-T-0037
 
Archive Date
6/18/2009
 
Point of Contact
Riyadh Saud, Phone: 435-831-3429
 
E-Mail Address
riyadh.saud@us.army.mil
(riyadh.saud@us.army.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in subpart 12.6 of the FAR (Federal Acquisition Regulation) as supplemented with additional information included in this notice. THIS IS A NOTICE OF INTENT TO NEGOTIATE ON A SOLE SOURCE BASIS WITH CEREX MONITORING SOLUTIONS LLC, 1294 BERNADETTE LANE, ATLANTA GA 30329-3446, TEL: 678-570-6662. FAX: 404-355-2218 FOR THE ACQUISITION OF A ULTRAVIOLET (UV) SENTRY AND CANARY SYSTEM UPGRADE. PURSUANT TO 10 U.S.C. 2304 (C)(1) AND FEDERAL ACQUISITION REGULATION 6.302-1, SUPPLIES, SERVICES AND/OR EQUIPMENT ARE AVAILABLE FROM ONE RESPONSIBLE SOURCE AND NO OTHER TYPE OF SUPPLIES, SERVICES AND/OR EQUIPMENT WILL SATISFY AGENCY REQUIREMENTS. U.S. Army Dugway Proving Ground, Directorate of Contracting is contemplating the procurement of the following: The three Cerex UV Sentry systems owned and operated by U.S. Army Dugway Proving Ground (DPG) installation must have IRIG time synchronization capabilities added to the systems. The upgrades will include the purchase and integration of IRIG time synchronization hardware as well as modifications to the onboard software to allow the UV Sentry systems to communicate with the IRIG hardware. In addition, all UV Sentry and UV Canary systems must be upgraded for faster data processing and more data storage space. Each of 3 UV Sentry systems and 3 UV Canary systems owned and operated by DPG must have the following system component upgrades: (a) CLIN 0001: Upgrade the current 1GHz controller to a 2 GHz model; (b) CLIN 0002: Upgrade the RAM on each system to a total of 1 Gigabyte; (c) CLIN 0003: Increase hard disk space to 64 Gigabytes; (d) CLIN 0004: Install the latest Continuous Monitoring software available; and (e) CLIN 0005: Modify the systems so that the system clock and all recorded data is synchronized with Universal Time (UTC). The required system modifications will include the installation of necessary hardware components as well as installation and/or modification of system software to communicate properly with time synchronization hardware. This announcement constitutes the only solicitation requested and a written solicitation will not be issued. Supporting evidence must be furnished to demonstrate the ability to comply with the government’s requirements. The solicitation is issued as a request for quote (RFQ). Submit written offers on RFQ W911S6-09-T-0037. All firms responding must be registered with the Central Contractor Registration (CCR). The Federal Supply Class (FSC) is 6650.. The Standard Industrial Classification (SIC) is (7382). North American Industrial Classification Standard (NAICS) is 334516. Size standard is 500 employees. The following provisions and/or clauses apply to this acquisition: FAR 52.212-1; FAR 52.212-3; FAR 52.212-4; FAR 52.212-5; FAR 52.219-6, FAR 52.222-3; FAR 52.222-19; FAR 52.222-21; FAR 52.222-26; FAR 52,222-39; FAR 52.225-13; FAR 52.232-33; DFARS 252.212-7001;FAR 52.203-3, DFARS 252.203-7000; DFARS 252.227-7015; 252.227-7037, DFARS 252.232-7003; DFARS 252.247-7023 Alt III; FAR 52.204-7; DFARS 252.211-7003, DFARS 252.232-7010; FAR 52.247-34 [FOB Destination] (Dugway, UT 84022), and DFARS 252.204-7004. The following local clauses apply to this solicitation: Foreign Visitors / Employees; Location of U.S. Army Dugway Proving Ground; Normal Work Hours; Installation Security Requirement; Submission of Invoices; Contractor Access to DPG; OSHA Standards and Identification of Contractor Employees; Department of the Army personnel reporting system; Legend of acronyms and brevity codes. All quotes must be emailed to Mr. Riyadh, Saud at riyadh.saud@us.army.mil in either Microsoft Office or Adobe Acrobat PDF format. For any questions or concerns you may email Mr. Riyadh Saud at riyadh.saud@us.army.mil. All Quotes must contain (W911S6-09-T-0037 and PR# W909NB9100C301 as a reference). Quotes are due no later than05:30 PM (prevailing local time at U.S. Army Dugway Proving Ground, Utah), Thursday, June 8, 2009.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/DABJ/DABJ19/W911S6-09-T-0037/listing.html)
 
Place of Performance
Address: 1294 BERNADETTE LANE, ATLANTA, Georgia, 30329-3446, United States
Zip Code: 30329-3446
 
Record
SN01830135-W 20090530/090529000113-98ee23fc578b10956411ed9c2e209b4d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.