Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 03, 2009 FBO #2746
MODIFICATION

Y -- Construct Shelter for Assured Fuels Research Equipment

Notice Date
6/1/2009
 
Notice Type
Modification/Amendment
 
NAICS
237120 — Oil and Gas Pipeline and Related Structures Construction
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, 88 CONS/PK, 1940 ALLBROOK DRIVE, WRIGHT-PATTERSON AFB, Ohio, 45433-5309, United States
 
ZIP Code
45433-5309
 
Solicitation Number
FA8601-09-R-0052
 
Archive Date
12/31/2009
 
Point of Contact
James Bane, Phone: 9375224564, Tim Hayes, Phone: 937-522-4546
 
E-Mail Address
james.bane@wpafb.af.mil, tim.hayes@wpafb.af.mil
(james.bane@wpafb.af.mil, tim.hayes@wpafb.af.mil)
 
Small Business Set-Aside
N/A
 
Description
This notice is posted in accordance with FAR 5.2 and 36.213-2. This is an UNRESTRICTED ACQUISITION for Full and Open Competition. The NAICS Code is 237120 and the Size Standard is $33.5M. SOLICITATION NUMBER: FA8601-09-R-0052 Project 080009 is to construct a shelter for assured fuels research equipment at Wright-Patterson AFB, Ohio. The AFRL Propulsion Directorate has acquired advanced fuels research equipment to develop, test, and evaluate industrial processes for generating aerospace fuel from a blend of petroleum and Fischer-Tropsch produced fuels derived from unconventional sources such as natural gas, coal, biomass, bio-oils, synthetic gasses, etc. The project scope consists of constructing a 40' x 100' (4,000 S.F.) facility south of facility 20490. Facility work includes excavation, foundations, steel frame structural system, building skin (fenestration), roof, interior facility utilities (electrical, plumbing, fire suppression, and HVAC, etc), and an interior process control room. Exterior utilities include rerouting and providing new electrical primary/secondary, water main/secondary, COMM duct bank/manholes, sewer (storm and sanitary), natural gas secondary, and gaseous nitrogen to the new facility and exterior equipment. Exterior equipment includes a natural gas compressor station, regenerative thermal oxidizer, boiler, air compressor, chiller, diesel fuel emergency generator, etc. Estimated magnitude of proposed acquisition is between $1,000,000 and $5,000,000. Special Concerns/Requirements: The technical nature of this project requires careful attention to detail and a contractor with specialized experience in the design (licensed fire protection engineer) and installation of fire alarm systems. The contractor shall also have experience with cryogenic piping systems, natural gas services, high voltage electric, and EPA requirements for water and sanitary systems. It is imperative that the contractor have a vigorous safety program site conditions. The contractor will be working adjacent to an existing fuel farm, which contains thousands of gallons of specialized fuel blends. Normal scheduling and coordination between trades will be required for the successful execution of this project. In accordance with FAR 4.1102 and DFARS 252.204-704 "Required Central Contractor Registration," Contractor must be registered in CCR prior to award. Registration may be accomplished at http://www.ccr.gov. NOTES: 1. The solicitation, specifications, and drawings will be available on the World Wide Web on or about 19 June 2009 at: http://www.fbo.gov. The tentative date for receipt of proposals is 31 July 2009. The period of performance is 365 days. 2. Copies of the specification and drawings will be available for inspection at Dayton Builders Exchange, Minority Contractors Business Assistance Program, and F. W. Dodge Division. No other hard copies will be available. 3. There is no fee for this solicitation. 4. A registration page will be attached to the web site. You are not required to register. However, when you register, you will receive notice of any amendments and/or addenda that may be issued to the solicitation. If you have not registered, it will be your responsibility to check the web site for any changes to the solicitation. 5. You shall provide a signed copy of the SF 1442 at the time and place specified in the solicitation for receipt of proposals. There will not be a public opening. Sealed envelopes containing proposals shall be marked to show the offeror's name and address, the solicitation number, and the date and time proposals are due. 6. Contractors shall be capable of securing bonding for the total proposed amount (base plus options). However, contractors shall only be responsible for providing bonding for the base amount plus the amount of any/all options exercised at the time of award. If an option is exercised after award, contractors shall be responsible for securing the additional bonding equal to the amount of the option. 7. Contractors that are Debarred, Suspended, or Proposed for Debarment are excluded from receiving contracts. Agencies also shall not consent to subcontract with these contractors. 8. This is a WPAFB Construction Contracting (PKJ) program. The current status is Pre-Solicitation and it is a Category Y - Construction of structures and facilities.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/88 CONS/FA8601-09-R-0052/listing.html)
 
Place of Performance
Address: South of facility 20490, Area B, Wright-Patterson AFB, Ohio, 45433, United States
Zip Code: 45433
 
Record
SN01832908-W 20090603/090601235532-52918762e03874648cb5c719fac69bca (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.