SOLICITATION NOTICE

Y -- RECOVERY--Y--Back-up Generators

Notice Date
6/16/2009
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
335312 — Motor and Generator Manufacturing
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, U.S. Army Engineer District, Fort Worth, US Army Engineer District, Fort Worth, PO Box 17300/819 Taylor Street, Fort Worth, TX 76102-0300
 
ZIP Code
76102-0300
 
Solicitation Number
W9126G-09-T-0096
 
Response Due
6/29/2009
 
Archive Date
8/28/2009
 
Point of Contact
linda mckethan, 254 939-1829<br />
 
E-Mail Address
US Army Engineer District, Fort Worth
(linda.mckethan@usace.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
RECOVERY-All questions regarding this SYNOPSIS should be submitted in writing to the following E-Mail address: Linda.N.McKethan@usace.army.mil. This Acquisition shall be competed as a SMALL BUSINESS SET-ASIDE. This synopsis is for the purpose of a pre-solicitation notification only. A Small Business Set Aside solicitation shall be issued for (2) Emergency Generators. Contract will be Firm Fixed Price (FFP). Specifications are: First Requirement is for (1) one 50k Standby/prime Generator to include: 120/208 voltage, 3 phase, and diesel fueled; full factory load-bank tested; 40kw alternator-Mecc Alte 12-lead reconnectable, vacuum impregnated with 300% start for ten seconds, single bearing, class H; industrial muffler (shipped loose); cool flow radiator with fan guards; fuel shut off solenoid valve-fuel filer; solenoid activated starter motor; dry type air cleaner. oil filter with internal bypass; oil and radiator drain extensions to allow easy change of fluids; battery charging alternator, engine driven; vibration isolators between engine/alternator and base frame; starting battery, battery rack and cables; main line circuit breaker; auto-start ready (two wire control), digital control panel displaying amps, volts and frequency; alarms and fault indicators for oil pressure; water temp, over-crank and over-speed; min/max alternator; low fuel level and emergency stop button; owners manual; standby warranty for one year. Second Requirement is for (1) one 75k Standby/prime Generator to include: 120/240 voltage 1 phase, diesel fueled; alternator; cool flow radiator with fan guards; fuel shut off solenoid valve-fuel filter; solenoid activated starter motor; battery charging alternator, engine driven; dry type air cleaner, oil filer with internal bypass; vibration isolators between engine/alternator and base frame; n wire control; digital control panel displaying amps, volts, and frequency; alarm and fault indicators; warranty two years or 1000 hours; weather resistant super silent enclosure. OPTIONS: battery charger, 12 v 5 amp; UL142 listed fuel tank sub base 150-gallons; automatic transfer switch 400 amp 2 pole NEMA 3R. Delivery within 60 days of award. MUST HAVE 24 HRS NOTICE FOR DELIVERY! The North American Industry Classification System (NAICS) code for this program is 335312, Motor and Generator Manufacturing with a corresponding Standard Industrial Code (SIC) of 3566 and a business size standard of 1000 employees. This solicitation will be issued via Internet only on FebBizOpps Website at www.fbo.gov. Notification of amendments shall be made via FebBizOpps only. It is the contractors responsibility to check the below-listed Internet address daily for any posted changes to this solicitation. No corrections and/or changes to proposals will be allowed after the proposal submittal due time and date. Estimated solicitation issue date is on or about the estimated date of June 12, 2009. Proposals are anticipated to be due on or about June 29, 2009. For security reasons, this solicitation and all technical data related to this solicitation will be distributed using the ARMY SINGLE FACE TO INDUSTRY (ASFI) web site: https://acquisition.army.mil/afsi/. Contractors are encouraged to utilize the function in FedBizOpps. Offerors must be registered with the Central Contractor Registration (CCR), in order to receive a Government contract award. To register, the CCR Internet address is: http://www.ccr.gov. ALL QUESTIONS REGARDING THIS SYNOPSIS/PRESOLICITATION NOTICE SHOULD BE SUBMITTED IN WRITING TO THE FOLLOWING E-MAIL ADDRESS: Linda.N.McKethan@usace.army.mil Point of Contact for this Synopsis and or Solicitation: Mrs. Linda McKethan. Email your questions to the US Army Corps of Engineers, Fort Worth District to the attention of Linda.N.McKethan@usace.army.mil. Administering Contracting Office: USACE-Capital Regional Office 3110 FM 2271 Belton, TX 76513
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA63/W9126G-09-T-0096/listing.html)
 
Place of Performance
Address: US Army Engineer District, Fort Worth PO Box 17300/819 Taylor Street, Fort Worth TX<br />
Zip Code: 76102-0300<br />
 
Record
SN01846754-W 20090618/090617000340-6910c411eaba49d954a49e0a913ba3ba (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.