SOLICITATION NOTICE

Z -- Install Auto Fire Detection System

Notice Date
6/19/2009
 
Notice Type
Presolicitation
 
NAICS
238990 — All Other Specialty Trade Contractors
 
Contracting Office
Department of the Air Force, United States Air Force Europe, 496 ABS/LGC - Moron, Moron AB, Unit 6585, Moron AB, Spain, 09643-6585
 
ZIP Code
09643-6585
 
Solicitation Number
FA5575-09-R-0017
 
Point of Contact
Elia M. Portz, Phone: +34 95 584-8017, Berchan A. Torrejon, Phone: 0034955848075
 
E-Mail Address
elia.portz@moron.af.mil, berchan.torrejon@moron.af.mil
(elia.portz@moron.af.mil, berchan.torrejon@moron.af.mil)
 
Small Business Set-Aside
N/A
 
Description
The United States Air Force intends to issue solicitation FA5575-09-R-0017 to solicit proposals for Firm-Fixed Price contract for the Installation of an Automatic Fire Detection System in Moron AB, Spain. The complete solicitation package will be available on the Federal Business Opportunity website for download on or after 3 July 09. The contract will consist of a period of performance of 210 calendar days. Contract magnitude is between $100,000 and $250,000 U.S. dollars. The successful contractor will be selected using Lowest Price Technically Acceptable with acceptable Past Performance resulting in the best value to the government. In accordance with the Agreement of Defense and Cooperation between the Kingdom of Spain and the United States of America, any contract resulting from this notice/solicitation can only be entered into with companies authorized to carry out these activities in Spain under Spanish law. Companies must meet the requirements established by Spanish legislation for execution of Government works. In addition, in accordance with the Office of Defense Cooperation Policy Directive 400- 5 "(4) Spanish material, labor, and equipment must be used if permitted by the requirements of the contract specifications." SCOPE OF WORK: The work includes, but is not limited to, the following items: Repair fire alarm system of buildings pertaining to fuel hydrant systems Phase I (Buildings 1503, 1506 and 1512) and Phase II (Buildings 1520, 1521 and 1523). Both groups of buildings are identical and the work to be performed in both phases the same, the scope of work shall be performed for only one phase. a. Remove the existing fire alarm system panel in building 1512, identifying the existing cable for reuse. b. Supply and install fire alarm system panel in 10 zones type FireShield FS1004 from Edwards. c. Supply and install explosion-proof photoelectric smoke detectors type Pyrotector model 30-3003, certified for Class I Group C and D at the locations indicated in the drawings. d. Supply and install thermo-velocimetric explosion-proof detectors type CR 135-EWT, certified for location Class I Group C and D at the locations indicated on the drawings. e. Supply and install explosion-proof manual pull devices type XAL-53 certified for location Class I Group C and D at the locations as indicated in the contract drawings. f. Supply and install explosion-proof bell type 439DEX-8AW-R, certified for location Class I Group C and D at the locations as indicated in the contract drawings. g. Supply and install fireproof interconnection electric lines of the different elements with single pole 1.5 mm² cable under ½ inch metal conduit pipe h. Final operational testing. i. Submit as-built drawings. j. Final cleaning of the installations. The above general outline and list of Principal Features of Work in no way limits or reduces the responsibility of the Contractor to perform all work as required by the project to provide a complete and operable facility. CERTIFICATION OF CLASSIFICATION: Bidders and/or their subcontractors must hold an updated Certificate of Classification issued by the "Registro Oficial de Contratistas de Obras del Estado" of the "Ministerio de Economia y Hacienda" or equivalent. Group Subgroup Category I 6 b K 9 b You are requested to notify the following E-Mail addressee if you intend to download the solicitation that will eventually be posted on this posting service; elia.portz@moron.af.mil. It is highly recommended that you register to be notified of any new postings for this solicitation and/or any other postings published by our office. However, failure of the service to notify you of changes cannot be used against the Government in any way, shape or form. Therefore, you should check FedBizOps, https://www.fbo.gov, frequently for any new postings that may have been made. The Government anticipates and reserves the right, to issue all solicitation documents including specifications and drawings in the English language only. A visit to the site of work will be conducted in English; the date and time of which will be announced in the solicitation documents. In order to be awarded a contract by the U.S. Government, the company must be registered in the Central Contractor Registry (CCR), contracts cannot be awarded to unregistered contractors. Registration can be made on line at www.ccr.gov NOTE: You must have a DUNS number and a NATO Commercial and Government Entity (NCAGE) Code to register. To obtain a Data Universal Numbering System (DUNS) Number you can contact Dun and Bradstreet and request one by calling: 902446688. To obtain a NATO CAGE code you must fill out the form found in : http://www.dlis.dla.mil/Forms/Form AC135.asp Failure to be registered in CCR at the time of award may delay the award and depending on the criticality of the project, may be cause to award to the next qualified best value offeror who is CCR registered. However, do not delay submitting your proposal pending receipt of a DUNS number or CAGE Code. Notice to Offerors: While FY09 funds may not be immediately available within USAFE to fund this project, funds have been provided for in the FY10 Financial Plan, therefore bid validity period should be extended to 30 Nov 09.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/USAFE/496ABSLGC/FA5575-09-R-0017/listing.html)
 
Place of Performance
Address: Moron Air Base, Moron de la Frontera, Sevilla 41530, Spain
 
Record
SN01851052-W 20090621/090620000403-3e9a8a57701372d0ab270c3b57765c30 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.