MODIFICATION
Z -- RECOVERY - MXDP031040P2 - Repair/Upgrade HVAC P2, Network Control Center, B241
- Notice Date
- 6/23/2009
- Notice Type
- Modification/Amendment
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of the Air Force, Air Education and Training Command, Laughlin AFB Contracting Squadron, 171 Alabama Ave, Bldg 7, Laughlin AFB, Texas, 78843-5102
- ZIP Code
- 78843-5102
- Solicitation Number
- F2R3C19036A001
- Archive Date
- 7/8/2009
- Point of Contact
- Teresa L Yancey, Phone: (830)298-4694, Juanita Vasquez, Phone: 830-298-5115
- E-Mail Address
-
teresa.yancey@laughlin.af.mil, juanita.vasquez@laughlin.af.mil
(teresa.yancey@laughlin.af.mil, juanita.vasquez@laughlin.af.mil)
- Small Business Set-Aside
- N/A
- Description
- THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO CONTRACTORS UNDER THE MULTIPLE AWARD CONSTRUCTION CONTRACT PROGRAM AT LAUGHLIN AFB. Repair/upgrade the HVAC equipment in building 241 at Laughlin AFB, TX. Provide all A/E Services for the design-build of the new HVAC system for the server room/ NCC area. The design will require development of specifications and calculations for a hot water reheat system. This reheat system will be installed by the contractor and piped from the mechanical room over to each of the two Liebert units. The Liebert units are currently servicing the NCC server area. The new design will consider every aspect affected by the hot water reheating system, such as, but not limited to; piping schemes to incorporate the reheating system, new boiler specifications in order to meet current requirements and energy efficiency ratings, and specifications for a hot water pump. Remove/replace one air cooled chiller, remove/replace one air handler unit and associated ductwork, remove existing HVAC controls systems (pneumatic systems, Johnson DSC, and electrical controls), install direct digital controls (DDC), install a fan coil unit, remove/replace the building fire alarm panel and install fire detection and signaling devices inside the NCC and network server areas. The estimated magnitude of this project is between $250,000 and $500,000. The Request for Proposal will be issued on or about 24 Feb 2009 and will close on or about 9 March 2009.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AETC/LaugAFBCS/F2R3C19036A001/listing.html)
- Place of Performance
- Address: Laughlin AFB, Del Rio, Texas, 78843, United States
- Zip Code: 78843
- Zip Code: 78843
- Record
- SN01852866-W 20090625/090623235141-bcd6b3333288c868b8318fc67b63839d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |