Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 03, 2009 FBO #2776
SOURCES SOUGHT

Y -- RECOVERY--Y--PICAYUNE STRAND RESTORATION PROJECT, MERRITT PUMPING STATION, FLORIDA

Notice Date
7/1/2009
 
Notice Type
Sources Sought
 
NAICS
237990 — Other Heavy and Civil Engineering Construction
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, U.S. Army Engineer District, Jacksonville, US Army Engineer District, Jacksonville, P.O. Box 4970, Jacksonville, FL 32232-0019
 
ZIP Code
32232-0019
 
Solicitation Number
W912EP-113275
 
Response Due
7/16/2009
 
Archive Date
9/14/2009
 
Point of Contact
Patricia H. Phillips, 904 232-1748<br />
 
E-Mail Address
US Army Engineer District, Jacksonville
(patricia.h.phillips@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
THIS IS A REQUEST FOR INFORMATION ONLY. The purpose of this synopsis is to gain knowledge of interest, capabilities and qualifications of various members of industry, namely the Small Business Community to include HubZone, Section 8(a), and Service-Disabled Veteran-Owned Small Business (SDVOSB). The Government must ensure there is adequate competition among the potential pool of responsible contractors. This sources sought announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. NOTE: IF YOU DO NOT INTEND TO SUBMIT A BID ON THIS PROJECT WHEN IT IS FORMALLY ADVERTISED, PLEASE DO NOT SUBMIT A RESPONSE TO THIS SOURCES SOUGHT SYNOPSIS. If an adequate number of qualified respondents in any small business category is not received (i.e. two or more responsible firms), the government reserves the right to issue the solicitation on an unrestricted basis and all firms regardless of size shall be eligible and encouraged to compete for this project. Project Description. Picayune Strand Restoration Project, Merritt Pumping Station The Picayune Strand Restoration Project, Merritt Pump Station and Levees, Canals and Roads (referred to Project) is part of the Comprehensive Everglades Restoration Plan (CERP). The Project will help to restore the area known formerly as the Southern Golden Gate Estates to its pre-drainage hydrology and ecology, generating positive effects on the hydrology, vegetation and wildlife of the Project area and surrounding public lands. The Project consists of a pump station, tie-back levees, spreader berms and canal plugs which will slow water flowing through existing canals and redistribute it across the landscape. The construction of the Pump Station, which shall have 2-75 cfs pumps and 4-220 cfs pumps, for a firm capacity of 810 cfs and 6 bays, includes the following: Mechanical equipment to be provided and installed by the Contractor will include, but not be limited to, diesel pumps, traveling trash rakes, bridge cranes, standby diesel generators, vacuum priming systems, HVAC equipment, cooling water pumps, fresh water pumps, water treatment equipment, lubricating water equipment, potable water equipment, and other miscellaneous mechanical equipment. Electrical and Instrumentation equipment to be provided and installed by Contractor will include, but not be limited to, station power distribution systems, station switchgear, motor control centers, local and station programmable logic controllers to control and monitor all ancillary mechanical equipment, grounding cable system, lighting, Control Room Operator Work Station with monitoring and control computers, uninterrupted power service equipment, remote terminal unit system, all supporting switches, wiring, conduits, junction boxes, etc. to interconnect with equipment for control and monitoring. The Contractor shall furnish and install a transformer pad and the primary conduit per Florida Power and Light (FP&L) requirements. The Contractor shall install the primary conduits provided by FP&L that run from the FP&L termination pole to the new primary transformer. The Contractor shall furnish and install the secondary 480 v building service conduits and cables and terminate both ends of the service cables. FP&L shall provide and install the primary transformer, the termination pole, and the primary cables. The Contractor shall furnish and install an 80 foot radio antenna tower. The Contractor shall furnish and install an electrical conduit from the control room to the radio antenna towers. The Contractor shall provide and install the antennas and Remote Terminal Units at the pump station. Construction of the station will include, but not be limited to, excavation, station substructure, backfill, fully enclosed buildings for the equipment, access bridges, fuel storage areas with containment and all associated equipment, sanitary facility, approach and discharge canals, retaining walls, trash racks, and related civil works. The Work will also include, but not be limited to, the pumping stations' approach and discharge canals. Contractor shall be responsible for operating and maintaining the existing construction access roads, existing Construction Village area infrastructure including sanitary, waste removal, mowing, asphalt repair, and site drainage consisting of small ditches, culverts and pumps, and providing overall security for the Construction Village. Contractor shall construct tie-back levees, spreader berms and canal plugs. Magnitude of Construction - $25 Million - $100 Million Please provide a Statement of Capability (SOC) stating your skills, experience, and knowledge required to perform the specified type of work. This SOC should be a brief description of your companys capabilities. The potential bidders should provide brief references of relevant work they have performed and the magnitude of construction. Interested contractors must also include bonding information (on the bonding company letterhead) that the company has the capability to provide bonding up to $100 million. Receipt of potential offerors SOC shall be no later than fifteen (15) calendar days from the date of this notice by 4:00 pm. Responses to this sources sought may be faxed, to the attention of Kathleen Duke at (904) 232-3713, mailed to U.S. Army Corps of Engineers, Contracting Division, 701 San Marco Blvd., Jacksonville, Florida 32202; or sent via email to patricia.h.phillips@usace.army.mil. DO NOT SUBMIT PROPRIETARY AND/OR BUSINESS CONFIDENTIAL DATA You must be registered in the Central Contractor Registration in order to be eligible to receive an award from any Government solicitation. Call 1-888-227-2423 for more information or visit the CCR website at http://www.ccr.gov. You must be registered in the Online Representations and Certifications Application (ORCA) in order to be eligible to receive an award from any Government solicitation. For more information, visit the ORCA website at http://orca.bpn.gov. NAICS Code is 237990 and the Small Business size standard is $33.5 million.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA17/W912EP-113275/listing.html)
 
Place of Performance
Address: US Army Engineer District, Jacksonville P.O. Box 4970, Jacksonville FL<br />
Zip Code: 32232-0019<br />
 
Record
SN01862540-W 20090703/090702001014-0afc9611f4b144bb2071aecb9e01c21f (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.