SOLICITATION NOTICE
Y -- Manhattan Emergency Generator Installation.
- Notice Date
- 7/24/2009
- Notice Type
- Presolicitation
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- Department of the Army, U.S. Army Corps of Engineers, US Army Engineer District, Philadelphia, US Army Engineer District, Philadelphia, 100 Penn Square East, Wanamaker Bldg (RM 643), Philadelphia, PA 19107-3390
- ZIP Code
- 19107-3390
- Solicitation Number
- W912BU-09-B-0042
- Response Due
- 9/9/2009
- Archive Date
- 11/8/2009
- Point of Contact
- Ryan Annibali, 215-656-6295<br />
- E-Mail Address
-
US Army Engineer District, Philadelphia
(ryan.r.annibali@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- This project entails the installation of a new 2,800 KW, prime rated, 4160V generator as well as associated paralleling switchgear for the future installation of a second generator with space provisions for a third generator. New pads shall be constructed in the existing grass area adjacent to the existing generator room to house the new equipment associated with the project (generator, fuel filtration building, paralleling switchgear). A 2,000 KW resistive load bank shall be provided and installed on a separate pad and wired to the paralleling switchgear to allow for testing of the new generator. Modifications shall be required to the existing kirk-key interlock system to enable the manual transference of building loads to the new generator upon loss of utility power via a new 600A, 4160V rated switch. The existing parking lot shall be demolished for the installation of (3) new 15,000 gallon underground diesel fuel storage tanks. The existing car stackers shall be removed, stored off-site and reinstalled when the new parking lot is installed. Existing underground sewer and storm piping shall be relocated as required with new man-holes for the installation of the new tanks. Solicitation Number W912BU-09-B-0042 will be issued on or about 07 August 2009 with a bid opening date of 09 September 2009. Estimated cost range of the project is between $5,000,000.00 and $10,000,000.00. The NAICS Code for this project is 236220 with a size standard of $33,500,000.00 million. Solicitation documents, plans and specifications will only be available via the Federal Business Opportunities (FBO) homepage located at https://www.fbo.gov/. Plans and specifications will be made available via FBO Internet homepage and hard copies will not be available. No written or fax requests will be accepted. It is the contractors responsibility to monitor FBO for any amendments. Also, contractors who receive a federal contract of $100,000.00 are required by legislation (FAR 22.1310(b)) to submit an annual VETS-100 Report on your employment of targeted veterans. Information on submitting your report may be obtained by calling 1-703-461-2460 or by accessing the following Internet website: http://vets.dol.gov/vets100/. All contractors must be registered in the DODs Central Contractor Registration database as required by DFARS 204.7300. Davis Bacon rates will be applicable to the construction and bonding is required. Please review all bonds and accompanying documents required to be submitted. Affirmative action to insure equal employment opportunity is applicable to the resulting contract. Liquidated damages will be specified. Award will be made as a whole to one bidder. This procurement is advertised unrestricted.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA61/W912BU-09-B-0042/listing.html)
- Place of Performance
- Address: US Army Engineer District, Philadelphia 100 Penn Square East, Wanamaker Bldg (RM 643) Philadelphia PA<br />
- Zip Code: 19107-3390<br />
- Zip Code: 19107-3390<br />
- Record
- SN01886573-W 20090726/090724235920-4ad56dfb4be78a6503fffc619391d445 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |