SOLICITATION NOTICE
66 -- STENCIL WASHER MO AUTOMATIC MISPRINT AND STENCIL CLEANING SYSTEM
- Notice Date
- 7/29/2009
- Notice Type
- Presolicitation
- NAICS
- 335999
— All Other Miscellaneous Electrical Equipment and Component Manufacturing
- Contracting Office
- NASA/Goddard Space Flight Center, Code 210.M, Greenbelt, MD 20771
- ZIP Code
- 20771
- Solicitation Number
- 4200300119
- Response Due
- 8/13/2009
- Archive Date
- 7/29/2010
- Point of Contact
- Sherika D. Wilson, Contract Specialist, Phone 301-286-1291, Fax 301-286-6299, Email Sherika.D.Wilson@nasa.gov<br />
- E-Mail Address
-
Sherika D. Wilson
(Sherika.D.Wilson@nasa.gov)
- Small Business Set-Aside
- N/A
- Description
- NASA/GSFC has a requirement for a Stencil Cleaning System and Related Accessories.NASA needs a multipurpose system to fit into the same footprint as the existing systembut which could clean both PWA board flux residue and stencil solder paste.Specifications:Stencil Washer MO Automatic Misprint and Stencil Cleaning SystemIncludes: Safety interlocked NEMA electrical enclosure, drip pan, capacity to hold 110%of wash and rinse solutions, safety listing include ETL listing, NFPA 70, 79; IEC; NEMA1, 12, Maximum misprint or stencil capacity of 32 x 30 (812.8 mm x 763mm), Automatedassembly transport elevator, Universal Stencil Mount, Misprint assembly fixture,Closed-Loop wash solution filtration and re-use system, wash solution Integratedsedimentation system and 10 micron inline filter, wash solution heating system with 130degrees F (54 degrees C) Capacity, wash solution powered drain (for wash solutionexchange), rinse tank 5 micron filtration system, rinse water power drain, Ambient VortexAir knife drying system, Auto-prime, X 30A Spring Loaded PCB Holder, X 30A Misprint & PCBWater knife Final Rinse.Filter Change Notification SystemClosed Loop D.I. Rinse for X30/X 40 A&C with Resistivity Controller, includes:5-micron filtration, Operator Interface, readout and RS232 S.P.C. output, Media Columnsnot included.0.5 Ft3 SST mixed resin bed (&lt;190 F)Heated Vortex Dryer Temperature can be set as high as 180 degrees F, typicalset points are 155 degrees F for PCBsNitrogen conservation SystemStencil washer MP Vent HoodEquipment set up and TrainingPackaging Wooden PalletNASA/GSFC intends to purchase the items from Moog Components Corporation because theymeet our technical requirements of down-time and return to operations requirements, theycan match our existing footprint and they have the same interconnectivity requirement(same venting location, same compressed air location) as the current system.The Government intends to acquire a commercial item using FAR Part 12.Interested organizations may submit their capabilities and qualifications to perform theeffort in writing to the identified point of contact not later than 4:30 p.m. local timeon August 6, 2009. Such capabilities/qualifications will be evaluated solely for thepurpose of determining whether or not to conduct this procurement on a competitive basis. A determination by the Government not to compete this proposed effort on a full and opencompetition basis, based upon responses to this notice, is solely within the discretionof the government.Oral communications are not acceptable in response to this notice.All responsible sources may submit an offer which shall be considered by the agency.An Ombudsman has been appointed. See NASA Specific Note "B".Any referenced notes may be viewed at the following URLs linked below.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/NASA/GSFC/OPDC20220/4200300119/listing.html)
- Record
- SN01891023-W 20090731/090730000122-c0e1d6821861f377f60edf7a5a58aca8 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |