Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 17, 2009 FBO #2823
SOLICITATION NOTICE

Y -- RECOVERY--Y--Repair Pre-Action Deluge Sprinkler System in Hangar 2049, Fort Drum, NY.

Notice Date
8/15/2009
 
Notice Type
Presolicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Army, Army Contracting Agency, North Region, ACA, Fort Drum, ACA, Fort Drum, Directorate of Contracting, 45 West Street, Fort Drum, NY 13602-5220
 
ZIP Code
13602-5220
 
Solicitation Number
EH-00087-9J
 
Response Due
8/17/2009
 
Archive Date
10/16/2009
 
Point of Contact
Cindy L. McAleese, 315-772-4112<br />
 
E-Mail Address
ACA, Fort Drum
(cindy.mcaleese@us.army.mil)
 
Small Business Set-Aside
N/A
 
Description
RECOVERY--THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO THE CONTRACTOR UNDER THE EXISTING FORT DRUM REPAIR, REHABILITATION AND CONSTRUCTION (RRC) Contract Number W911S2-06-D-0006, Contractor: Alutiiq Global Solutions, LLC, 3033 South Parker Road, Suite 1111, Aurora, CO 80014. The Directorate of Contracting will obtain services to provide all supervision, plant, labor and equipment necessary to perform all work in connection with installing a closed head pre-action sprinkler system and fire alarm system in Hangar P-2049 to protect the hangar bays. Sprinkler coverage must provide coverage throughout 100% of the building except as permitted by NFPA 13 and shall conform to the latest version of UFC 3-600-01. This includes, but is not limited to, telephone rooms, electrical equipment rooms, and other electrical and mechanical spaces. The sprinkler system shall be supplied by the domestic water system and not the airfield closed loop fire water system. Backflow prevention is required for the water supply. Existing foam concentrate will be disposed of and new foam concentrate will be provided. The existing foam concentrate tanks shall be re-used. The new fire alarm system will be an addressable, self-interrogation alarm/detection system with mass notification capabilities. Edwards, Notifier or equivalent systems shall be installed, as well as Monaco transmitters. The system will be tested prior to completion. The magnitude of this project is estimated to be between $500,000 and $1,000,000. The project will be funded by the American Recovery and Reinvestment Act of 2009. This is not a request for quotation or a solicitation for offers.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/DABJ/DABJ17/EH-00087-9J/listing.html)
 
Place of Performance
Address: ACA, Fort Drum Directorate of Contracting, 45 West Street Fort Drum NY<br />
Zip Code: 13602-5220<br />
 
Record
SN01913382-W 20090817/090815233601-dfac543a98f0d8723ab09c263c9006eb (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.