Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 22, 2009 FBO #2828
SOLICITATION NOTICE

J -- REPAIR & REPLACE TWO FIRE SPRINKLER SYSTEMS

Notice Date
8/20/2009
 
Notice Type
Presolicitation
 
NAICS
922160 — Fire Protection
 
Contracting Office
Department of the Navy, Bureau of Medicine and Surgery, NH Guam, Bldg #1, L-Wing, Rm K116, Farenholt Road, Agana Heights, 96919
 
ZIP Code
96919
 
Solicitation Number
N6809609RC90163
 
Archive Date
9/19/2009
 
Point of Contact
Fia T Moso, Phone: 6713449297, Fia T Moso, Phone: 6713449297
 
E-Mail Address
fia.moso@med.navy.mil, fia.moso@med.navy.mil
(fia.moso@med.navy.mil, fia.moso@med.navy.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
This is a Pre-Solicitation Notice, U S Naval Hospital, Guam for a firm fixed price type contract for repair and replacement of a Four-Inch (4") Riser Detail on a Wet Type Fire Sprinkler System at two (2) different locations behind Building #4, U S Naval Hospital, Guam. The solicitation and any subsequent amendments will be posted on the Navy Electronic Commerce Online (NECO) website: www.neco.navy.mil. Proposed contract procured utilizing Simplified Acquisition Procedures. Vendor must have Cage Code and Dun #. Must be register on Central Contracting Registration (CCR). Area of consideration is Guam contractors ONLY. PLEASE SEE STATEMENT OF WORK (SOW) BELOW FOR DETAILS. US NAVAL HOSPITAL, GUAM FACILITIES MANAGEMENT DEPARTMENT I.STATEMENT of WORK: The contractor shall provide all labor, materials, equipment, supervision and incidental related work necessary for the Repair by Replacement of 4" Riser Detail on a Wet Type Fire Sprinkler System at two (2) Locations behind Buildings 4, U.S. Naval Hospital, Guam. The work includes, but is not limited to the following: a.Remove and dispose of corroded 4" whole riser detail system at both location. b.Replace the following component system at both location: •4" diameter alarm check valve F x F. •4" diameter check valve F x F. •4" diameter OS&Y Gate valve F x F. •AV-1-300 alarm trim kit vertical and horizontal mount with gauges and valves. •Water motor alarm gong. •Potter electric pressure switch. •Retard chamber with trimmings. •4" diameter x 12" L flex pipe connector. •1" Test drain valve and associated components. c.Prepare, prime and paint pipes to include supporting brackets to match existing. d.Clean up jobsite and dispose of debris. II.SPECIAL CONDITIONS: 1)Construction and procedures shall be in conformance with the latest OSHA & NFPA. 2)Other incidental work required includes any and all items and considerations necessary to insure a complete and usable final product, including, but not limited to, the necessary design and construction considerations not specifically stated elsewhere in this statement of work. Complete and usable final product means that the completed final product can be used to fully satisfy the requirements and the intended purpose of this project. 3)Any utility support/outages required accomplishing the repairs of the existing 4" Riser Detail on a Wet Type Fire Sprinkler System at two (2) Locations behind Buildings 4, U.S. Naval Hospital, Guam shall be scheduled and coordinated with the BOS Contractor and prior notification shall be made to Naval Hospital Facilities Management Department. Any Cost for Utility Support shall be the responsibility of the Contractor. III.REQUIRMENT UPON CONTRACT AWARD: 1)Pre-construction: Contractor will meet with the Facilities Management Department (FMD) representatives on elaborative efforts and means of the work or job to be accomplished. IV.CONTRACT WORK ACCEPTANCE: 1)The Facilities Contract Manager will perform a PRE-FINAL/quality assurance inspection. All discrepancies identified during pre-final will be re-worked and performed accordingly. 2)A FINAL INSPECTION will be performed, project cleared, and approved by Facilities Management Department before contractor is relieved from work or contracted job. ________________________________________ Point of Contact: Albert C. Garcia Email address: albert.garcia@med.navy.mil Telephone: 344-9636 Fax: 344-9379 or 344-9288 NOTE: TO ALL INTEREST CONTRACTORS: The site visit for this job is 25 August 2009, start: 1:30pm end: 2:30pm. All interest contractors must be prompt.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/BUMED/N68096/N6809609RC90163/listing.html)
 
Place of Performance
Address: USNAVAL HOSPITAL GUAM, BLDG #1, L-WING, FARENHOLT ROAD, AGANA HEIGHTS, 96910, United States
Zip Code: 96910
 
Record
SN01920979-W 20090822/090821002425-47c9d67fb8a7a339d3ccb66821c8b4f8 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers