Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 13, 2009 FBO #2850
SOLICITATION NOTICE

59 -- INSULATION POWER FACTOR TEST SET & POWER QUALITY ANALYZER

Notice Date
9/11/2009
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
335999 — All Other Miscellaneous Electrical Equipment and Component Manufacturing
 
Contracting Office
US Army Humphreys Engineer Center Support Activity, ATTN: CEHEC-CT, 7701 Telegraph Road, Alexandria, VA 22315-3860
 
ZIP Code
22315-3860
 
Solicitation Number
W912HQ09T0034
 
Response Due
9/21/2009
 
Archive Date
11/20/2009
 
Point of Contact
Damon C. Moore, 703-428-8487
 
E-Mail Address
US Army Humphreys Engineer Center Support Activity
(damon.c.moore@usace.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Reference number is W912HQ-09- T-0034 is issued as a Request for Quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-36. This solicitation is a 100 percent set aside for small business; the associated NAICS code is 334515 and small business size standard is 500 employees. Line Item 0001 Quantity 1 (one); Megger Part Number 673001 (OR EQUAL) - Delta 3000 Automated Insulation Power Factor Test Set with PowerDB Onboard software. 12V/60Hz. Line Item 0002 Quantity 2 (two); Megger Part Number SK-P9P-US-EN-1 (OR EQUAL) PA-9 Plus Starter Kit includes PA-9 Plus (P9P00021-D1000), English Display, Kit of 4 fused voltage cables (CA-PA9-22) with crocodile clips and neutral jumpers, U.S. Aux input Charging Cable, External Data Transfer Memory Adapter, 128MB Compact Flash Data Card, Three (3) CP-600/6000CE current clamps, SC-PA9 soft-sided carrying case, MEGPA9IEC software and manual. Line Item 0003 - Shipping/Delivery destination and schedule is as follows: HHC 249th Engineer Battalion ATTN: CEPPB-H 1416 Jackson Loop Fort Belvoir, VA 22060 STATEMENT OF WORK EQUIPMENT PURCHASE Insulation Power Factor Test Set & Power Quality Analyzer Background: The 249th Engineer Battalion (Prime Power) deploys worldwide to provide prime electrical power and electrical systems expertise in support of the warfighter mission and National Response Plan. The units primary equipment assets are medium voltage generators and power plants that require special equipment for installation and calibration. In addition to ground power distribution, the prime power specialists are trained in overhead power distribution. Scope: The 249th Engineer Battalions Heavy Maintenance Section (HMS) will be set up by the end of FY 2010 as a fully operational 30-level maintenance shop supporting the Armys power generation and distribution equipment. The steps required in completing this mission include substantial purchases of electrical maintenance equipment. Insulation power factor tests are required to measure dielectric losses, which relate the wetness, dryness or deterioration of insulation. Both factory and field testing are performed to verify the insulation integrity of substation transformers. The results of overall power factor tests on power transformers reflect the insulation condition of the windings, barriers, tap changers, bushings and oil. This equipment will allow HMS to identify deterioration of transformers windings, generator windings, and power/load cables for all power generation and distribution equipment. The power Quality Analyzer gives the Heavy Maintenance Section the ability to conduct Energy Audits, Capacitor Bank Sizing, Load Balancing, Power Factor Surveys, Before/After Studies, Load Profiling, Substation Monitoring, Power Quality Investigations, Billing Verification, Motor Inrush Current Studies, and Harmonic Surveys/Filter Selection for all electrical power generation and distribution equipment through out battalion. Deliverables ITEMQUANTITY Automated Insulation power Factor Test Set1 Megger Priority Access Program1 Power Quality Analyzer2 Task Requirements: "The equipment include all the required software. "Include annual equipment calibration/ certification services "Priority repair services for hardware and software Period of Performance: Equipment should be delivered no later than 30 days after the award of this contract. Warranty Contractor shall provide a one year limited warranty on all parts and accessories installed by the manufacturer. Include cost of freight and delivery in the estimate. The Government will award a contract resulting form this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the government, price and other factors considered. Clauses may be accessed electronically in full text through http://farsite.hill.af.mil. Contractors must be actively registered with the Central Contractor Registration (CCR) at http://www.ccr.gov and at Online Representations and Certifications Application (ORCA) at http://orca.bpn.gov. The following provisions apply: FAR 52.212-1, Instructions to Offerors-Commercial. FAR 52.212-3, Offerors Representation and Certifications Commercial Item or complete electronic annual representations and certifications at http//orca.bpn.gov., FAR 52.212-4 Contract Terms and Condition-Commercial Items; FAR 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Item are incorporated by reference, however, for paragraphs (b) and (c) the following clauses apply. FAR 52.222-21 -Prohibition Of Segregated Facilities; FAR 52.222-26 Equal Opportunity; FAR 52.222-35- Affirmative Action for Disabled Veterans and Veterans of the Vietnam Era; FAR 52.222-36 Affirmative Action for Workers With Disabilities; FAR 52.222-37 -Employment Reports On Disabled Veterans And Veterans Of The Vietnam Era; FAR 52.232-33 -Payment by Electronic Funds Transfer--Central Contractor Registration; FAR 52.225-1, Buy American Act - Supplies; Offerors are reminded that the Buy American Act restricts the purchase of supplies that are not domestic end products, FAR 52.211-6, Brand Name or Equal (for commodities when purchase description is brand name or equal), 52.222-50, Combating Trafficking in Persons. The following DFARS clause is applicable: 252.212-7001 Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items with following clauses that apply: 52.203-3, Gratuities and 252.232-7003, Electronic Submission of Payment Requests and Receiving Reports. The date, time and request for quote offers are due: 3:00 P.M. EDST, 21 September 2009 to damon.c.moore@usace.army.mil or fax to Attn: Damon Moore @ 703-428-8181 or mail to Attn: Damon Moore; 7701 Telegraph Rd., Kingman Building; Alexandria VA. 22315. Point of Contact(s): Damon C. Moore, 703-428-6117
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA72/W912HQ09T0034/listing.html)
 
Place of Performance
Address: US Army Humphreys Engineer Center Support Activity ATTN: CEHEC-CT, 7701 Telegraph Road Alexandria VA
Zip Code: 22315-3860
 
Record
SN01952087-W 20090913/090912002825-a81f46371befebfea2fa5ef51866f338 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.