SOLICITATION NOTICE
70 -- Site Services
- Notice Date
- 9/22/2009
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 333415
— Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Contracting Office
- Department of Agriculture, Office of the Inspector General, Procurement Branch, 1400 Independence Ave., SW, Room 40-E J.L. Whitten Fed Bldg, Washington, District of Columbia, 20250
- ZIP Code
- 20250
- Solicitation Number
- OIG-324569
- Archive Date
- 9/24/2009
- Point of Contact
- Carol Franklin, Phone: 202-720-5931
- E-Mail Address
-
Carol.Franklin@oig.usda.gov
(Carol.Franklin@oig.usda.gov)
- Small Business Set-Aside
- Total Small Business
- Description
- Contractor to provide an Uninterruptible Power Supply (UPS) to inlcude the following: * 130kVA / 104kW * AC Input voltage 480V (three-phase, three-wire plus ground) * AC Output voltage 208V (three-phase, four-wire plus ground) * Single input * True on-line, double conversion, * IGBT pulse-width modulated (PWM) inverter * Internal maintenance bypass switch * DSP (Digital Signal Processing) Controls * Microprocessor based monitoring and control panel with mimic bus * LCD Graphic Display with Alarm History Database * Programmable battery load testing for added reliability * Load Neutral Isolation * Input filter with 10% THD at full output load * Open Comms - Network Interface Card (Ethernet SNMP) with software to e-mail/page-out UPS alarms * Local E.P.O. with provision for remote E.P.O. * UL 1778, CSA * Battery of 102 minutes at a 104kW load with 4 cabinets each cabinet with a battery circuit breaker to isolate the battery during maintenance, valve regulated lead acid battery cells in flame retardant cases, and the batteries provided with warranty * External Matching Maintenance Bypass Cabinet with single rotary handle switch interlocked for "make-before-break" transfer of the load, bypass transformer and output circuit breaker * 7x24 start-up a technician * 1 year parts and labor warranty with 4 hour guaranteed onsite response time during warranty period * System testing that includes verification with manufacturer provided resistive load bank of proper operation in all UPS operational modes (on inverter, on bypass, on battery, etc.) and proper transfer to and from each mode. Time duration in each mode shall be: 30 minutes. Load Bank and load bank cables are to be provided by manufacturer. Written report of testing will be provided. Manufacturer shall also provide infrared scanning using manufacturer provided IR camera, FLIR TCAM T400 or equal, to verify proper wire terminations. Scans to be performed within the UPS system cabinets. Full report shall be provided. * Freight. Send cost proposal electronically to Linda.Josey@oig.usda.gov not later than September 23, 2009 by 3:00 pm.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USDA/IG/CPB/OIG-324569/listing.html)
- Place of Performance
- Address: USDA, OFFICE OF INSPECTOR GENERAL, 8930 Ward Parkway, Kansas City, Missouri, 64114, United States
- Zip Code: 64114
- Zip Code: 64114
- Record
- SN01964765-W 20090924/090923000325-09256a0494b1b1316deec458aff36460 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |