SOLICITATION NOTICE
J -- Energy Management Control System Annual Preventive Maintenance
- Notice Date
- 9/24/2009
- Notice Type
- Presolicitation
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of Veterans Affairs;VISN 6 Centralized Acquisition Service;100 Emancipation Drive;Hampton VA 23667
- ZIP Code
- 23667
- Solicitation Number
- VA-246-09-RQ-0531
- Response Due
- 9/29/2009
- Archive Date
- 11/28/2009
- Point of Contact
- Kenneth HoodContract Specialist
- E-Mail Address
-
Contract Specialist
(kenneth.hood2@va.gov)
- Small Business Set-Aside
- N/A
- Description
- The VA Medical Center (VAMC) Durham, NC intends to negotiate a sole source commercial item procurement with Siemens Building Technologies to provide bi-monthly service on the Energy Management Control System. The system is a Siemens Insight front end network based application interfacing with field network cabinets and associated control points. The service shall include but not limited to: Onsite reviews of the HVAC Control System every other week to assure that it meets our changing needs; Coaching VAMC facility staff, Monday through Friday 8:00 a.m. to 5:00 p.m. System experts will assist operators in identifying, verifying and resolving problems found in executing tasks; Provide software and documentation updates to the existing APOGEE Insight software, as they become available, to include onsite training to familiarize VA staff with the new features and their associated benefits; Analyze and optimize automation controls in accordance with a program of standard routines, including preventive maintenance of network cabinets for voltage readings, pneumatic component leaks and processor operation; Back-up DVAMC's HVAC Control System Insight workstation software, graphics and field panel databases (4) times per year, and provide safe storage of this critical business information; Repair or replace components that are suspected of being faulty in advance to minimize the occurrence of system interruptions; Maintained equipment includes 1 Apogee Server/4 Clients, 47 Modular Building Controllers - MBC, Siemens 1 Gateway Controller, Siemens 1 FLN Controller, 22 Digital Point Units - DPU's, 919 Terminal Equipment Controllers - TEC,9 Apogee Ethernet Microserver (AEM), 35 Differential Pressure Monitors and 1 Multipoint Unit. This proposed contract action is for supplies or services for which the government intends to solicit and negotiate with only one source under the authority of FAR 6.302. This notice of intent is not a request for competitive quotes. However, interested parties may identify their interest and capability to respond to the requirement and submit quotations no later than 12 Noon, September 29, 2009 EST to: kenneth.hood2@va.gov or Fax: 757-728-3132. A determination by the Government not to compete this proposed contract based on responses to this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/HaVAMC/VAMCCO80220/VA-246-09-RQ-0531/listing.html)
- Record
- SN01969953-W 20090926/090925002203-15b56286297e09052783ba8d110bc612 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |