SOLICITATION NOTICE
Z -- Energy Retrofit for the ATF Facility in Martinsburg, WV
- Notice Date
- 10/8/2009
- Notice Type
- Presolicitation
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- General Services Administration, Public Buildings Service (PBS), Chesapeake Realty Services District (3PC), Mid-Atlantic Region, Wanamaker Building, 20 North 8th Street, 9th Floor, Philadelphia, Pennsylvania, 19107, United States
- ZIP Code
- 19107
- Solicitation Number
- GS-03P-10-DX-C-0003
- Archive Date
- 10/23/2009
- Point of Contact
- Anthony B. Teti, Phone: 2154464544
- E-Mail Address
-
anthony.teti@gsa.gov
(anthony.teti@gsa.gov)
- Small Business Set-Aside
- N/A
- Description
- American Recovery and Reinvestment Act (ARRA) Energy Retrofit for the ATF Facility 244 Needy Road Martinsburg, WV 8 October 2009 The General Services Administration is soliciting Design-Build Entities for the design and construction of a geothermal system and a photovoltaic solar array for the ATF Facility in Martinsburg, WV. Also included is the design and replacement of minor HVAC equipment and the adjustment of several systems to increase energy efficiency. These services will be performed at the GSA owned ATF Facility located at 244 Needy Road in Martinsburg, WV. The design and construction will be based on a Request for Proposal package which is currently being developed. The preliminary scope of this project has the following characteristics: Geothermal System: a ground source heat pump system that will provide heating and cooling to the building. Photovoltaic Solar Array: crystalline panel system on the roof and in the parking lot of the facility that will reduce the amount of energy consumed by the building. Replacement of the building's chillers and adjustments to the HVAC system in the building. Selection Process: GSA will utilize a two-step, best value, source selection process. Selection Factors: Phase I factors: Past Performance on similar projects Project Team experience Phase II factors: Project Management and Delivery Plan Oral Presentations Proposed Timeline for Procurement: GSA advertises Phase I Criteria: November 2009 GSA conducts a Pre-proposal Conference: November 2009 GSA develops a shortlist: January 2010 GSA advertises Phase II Criteria: January 2010 GSA selects a Design/Build Entity: March 2010 Inquiries concerning the project should be directed to: Anthony Teti, GSA Contracting Officer E-mail address: Anthony.Teti@gsa.gov
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/3PC/GS-03P-10-DX-C-0003/listing.html)
- Place of Performance
- Address: ATF Facility, 244 Needy Road, Martinsburg, West Virginia, United States