Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF OCTOBER 17, 2009 FBO #2884
SOLICITATION NOTICE

Y -- RECOVERY--Y--PROJECT NUMBER RM09-1363, INSTALL PHOTOVOLTAIC SYSTEMS, KAUAI, HI

Notice Date
10/15/2009
 
Notice Type
Presolicitation
 
NAICS
237130 — Power and Communication Line and Related Structures Construction
 
Contracting Office
N62478 NAVFAC HAWAII A-E/Construction/FSC PCO Branch 400 MARSHALL RD PEARL HARBOR, HI
 
ZIP Code
00000
 
Solicitation Number
N6247810R4020
 
Response Due
10/22/2009
 
Archive Date
10/30/2009
 
Point of Contact
James Murakami 808-474-7852 Primary: James Murakami 808-474-7852 james.murakami@navy.milAlternate: Katrida Collier 808-471-4209 katrida.collier@navy.mil
 
Small Business Set-Aside
Competitive 8(a)
 
Description
PROJECT NUMBER RM09-1363, INSTALL PHOTOVOLTAIC SYSTEMS, KAUAI, HI PER FAR 5.7 THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY; THEREFORE FAR 5.203 DOES NOT APPLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO CONTRACTOR(S) UNDER 8(a) MULTIPLE AWARD CONSTRUCTION CONTRACT (MACC), HAWAII; American Piping and Boiler Co. (N62478-07-D-4003); RMA Land Construction (N62478-07-D-4004); Niking Corporation (N62478-07-D-4005); Standard Sheetmetal & Mechanical, Inc. dba Standard Construction (N62478-07-D-4006); Su-mo/Nan JV (N62478-07-D-4007) Summary of Project Scope: This project will consist of design and construction of grid-tied building integrated photovoltaic power systems on the roof top of Buildings 328, 337, 338, 355, 359, 384, 801, 1260, 1261, and 1264, Pacific Missile Range Facility Barking Sands, Kauai, Hawaii. The design life of the system shall be at least 20 years in corrosive environment. The PV power systems shall produce aggregated energy output of 1.0 GWh during the first full year of operation and shall produce aggregated annual output equal to and at least 80% of the first year target for the remainder of its twenty-year life. It is anticipated that the aggregated system will contain PV panels/modules with output capacity of at least 787.8 KWP DC based on Standard Test Condition (STC) and will provide at least 590 KW AC of continuous power during peak daylight hours peculiar to the CRNH locations. The output from each of the PV power systems shall be designed to be the same AC voltage, waveform, and frequency as, and will be distributed via isolation transformer to, the nearest facility grid power panel. The PV power systems shall meet all current NEC and UL requirements, and designed in accordance with the current Naval Facilities Engineering Command Hawaii (NAVFAC-HI) Public Works Utilities Criteria. Completion of all construction shall occur within one year of contract award. The estimated construction cost is between $5,000,000 to $10,000,000. Contracting Office Address:N62478 NAVFAC Hawaii, Construction Acquisition Division (OPHA2), 400 Marshall Road, Pearl Harbor, HI 96860-3139
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N62742PH/N6247810R4020/listing.html)
 
Record
SN01986319-W 20091017/091015235457-c57462c137be860eee7d61b3c5a10970 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.