Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF OCTOBER 21, 2009 FBO #2888
MODIFICATION

Z -- RECOVERY - Replacement of Electrical Switch Gear at the Mississippi State, MS location

Notice Date
10/19/2009
 
Notice Type
Modification/Amendment
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of Agriculture, Agricultural Research Service, Mid South Area, Area Office, 141 Experiment Station Road, Stoneville, Mississippi, 38776, United States
 
ZIP Code
38776
 
Solicitation Number
AG-4431-S-09-0024
 
Point of Contact
Terry A Krutz, Phone: 662-686-5361
 
E-Mail Address
terry.krutz@ars.usda.gov
(terry.krutz@ars.usda.gov)
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Solicitation No. AG-4431-S-09-0024 Amendment No. 1 Site Visit Questions and Answers 1. Can the existing busway be replaced with an alternate distribution method? The existing underground conduits must be reused going to the transformer. Replace the existing busway entering the building with 4in conduits and 750MCM cables as indicated on E2. Provide new cables from the new MDP to the transformer. 2. Can the switchboard lineup be less than four sections? Alternate sections can be considered during the submittal process as long as the feeders are taken in account. 3. How many provisions for spare breakers are required within the new switchboard. Provide Minimum one space for each breaker frame size. Provide minimum 3 spaces. 4. Original Solicitation stated that this project is a 100% set-aside for Handicapped Veterans I believe. Is that still the case? Yes 5. Plans show a new duct bank, and an in-line ATS, On site professional stated that there was not a ATS in this project, and that the existing BussDuct would be re-used. Please clarify There is no ATS existing or in this project. Utilize the existing conduits from the transformer to the ATS location. Provide new conduits from the ATS location to the building. 6. Will a MS State electrical or local contractor's license be required to complete this project? None Required 7. Will this job be required to be permitted thru any local agencies or authority? No 8. Will this job require inspection by any local agencies or authority? No 9. Will all demo property remain with customer, or will contractor be responsible for removal and disposal? All demolished equipment is the contractors property and be removed. 10. Is the estimated magnitude of $100-250K including the generator/transfer switch to be installed later, of for the switchgear replacement only? Switchgear only 11. Is the dollar value for recovery money on this project available for public viewing? No 12. Would a list of contractors attending the bid meeting be available? Yes, but the list was not received in time for this amendment. Requests for the list can be made to the contracting officer.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USDA/ARS/MSAO/AG-4431-S-09-0024/listing.html)
 
Place of Performance
Address: 810 Highway 12 East, Mississippi State, Mississippi, 39762, United States
Zip Code: 39762
 
Record
SN01987638-W 20091021/091019234548-02696fbef888b963819504a39a713555 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.