Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF NOVEMBER 27, 2009 FBO #2925
SPECIAL NOTICE

Z -- RECOVERY - Replace Air Conditioning Unit, Install Occupancy Lighting Sensors and Weatherstripping.

Notice Date
11/25/2009
 
Notice Type
Special Notice
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
General Services Administration, Public Buildings Service (PBS), Property Management Division- Michigan Service Center, General Services Administration, Public Buildings Service, 477 Michigan Avenue, Detroit, Michigan, 48226, United States
 
ZIP Code
48226
 
Solicitation Number
RECOVERY-5PSSC1A-10-5022
 
Point of Contact
Miranda G. Webster, Phone: 313-226-5972, Cecilia P. Saylor, Phone: (313)226-2103
 
E-Mail Address
miranda.webster@gsa.gov, cissie.saylor@gsa.gov
(miranda.webster@gsa.gov, cissie.saylor@gsa.gov)
 
Small Business Set-Aside
N/A
 
Description
RECOVERY: THIS NOTICE IS FOR INFORMATIONAL PURPOSES ONLY. This opportunity is available only to contractors under the Michigan Service Center's existing IDIQ contracts for repair and alteration. This is not a request for quotation. This project is to increase energy efficiency at the Rosa Parks Federal Building, 333 Mount Elliott Avenue, Detroit, MI 48207. Work includes the installation of a new air cooled, roof mounted condensing unit and an indoor wall mounted air handler. Work also includes refrigerant piping and refrigerant charge, mounting of prefabricated I beam rails for the condenser, installation of prefabricated roof piping curb, installation of the water line for humidifier, and installation of the condensate drain. Demolition work includes the removal of the existing water cooled air conditioner and associated piping. Demolition and repair work also includes floor and roof penetrations for conduit, and roof patching. Electrical work consists of the installation of conduit, wiring, fused disconnect switches, control wiring, and a new 3p breaker in the existing panel board. Electrical work also includes the installation of a 120 volt GFI service receptacle mounted adjacent to the condensing unit. Additionally, occupancy lighting sensors throughout the building will be installed along with weatherstripping around building entrances. This opportunity is only available to the current contract holders. THIS IS NOT A REQUEST FOR QUOTATION. This acquisition is subject to the North American Industry Classification Systems (NAICS) code of 236220 and to Product Service Code (PSC) Z111. Any questions regarding this notice must be submitted in writing or via email to the primary or secondary point of contact contained in this announcement.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/5PT3/RECOVERY-5PSSC1A-10-5022/listing.html)
 
Place of Performance
Address: Rosa Parks Federal Building, 333 Mount Elliott Street, Detroit, Michigan, 48207, United States
Zip Code: 48207
 
Record
SN02011550-W 20091127/091125234848-e6d4357f6578bf37c2dff0af0c61373c (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers