MODIFICATION
M -- Facilities Operations & Maintenance Services at the IRS Fresno Campus
- Notice Date
- 12/10/2009
- Notice Type
- Modification/Amendment
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of the Treasury, Internal Revenue Service (IRS), Field Operations Branch Western (OS:A:P:B:W), 333 Market Street, Suite 1400, San Francisco, California, 94105-2115
- ZIP Code
- 94105-2115
- Solicitation Number
- TIRWR-10-FRESNO
- Archive Date
- 1/29/2010
- Point of Contact
- Denise G Alvarez, Phone: 510-637-2133, Ashley Loper, Phone: 510-637-2126
- E-Mail Address
-
denise.alvarez@irs.gov, ashley.loper@irs.gov
(denise.alvarez@irs.gov, ashley.loper@irs.gov)
- Small Business Set-Aside
- Total Small Business
- Description
- Internal Revenue Service Fresno Campus Facilities Operations & Maintenance Services Sources Sought Notice THIS IS A SOURCES SOUGHT NOTICE AND SHOULD NOT BE CONSTRUED AS A SOLICITATION ANNOUNCEMENT. The purpose of this notice is to gain knowledge of potential qualified small business concerns capable of performing operation and maintenance services under North American Industry Classification System (NAICS) code 238220 for plumbing, heating and air-conditioning contractors. The small business size standard is $14M. A review of the responses to this sources sought announcement will assist the Government in determining if competition should be restricted to small business concerns and may result in a solicitation announcement being published in the Federal Business Opportunities on or about February 01, 2010. The Internal Revenue Service (IRS) has a requirement for critical facility operation and maintenance services including operations and maintenance of a critical data processing center and related facilities. Basic services shall include operations, repairs, and maintenance of critical building system such as rotary uninterruptible power supplies in parallel, (ranging from 15 KVA up to 250 KVA) and emergency generators in parallel (up to 100 KVA1-100 KVA). ADP/Mainframe room HVAC, central cooling and heating plant, plumbing and electrical systems, building temperature control, routine equipment checks and inspections, equipment room and contractor space maintenance, painting and corrosion control, utility meter monitoring, water treatment services, routine, urgent and emergency service call management, and preventive maintenance performance and scheduling of equipment. Also include are new construction and repair IDIQ projects limited to <$500k. Services will be performed at the Sub-Mission Processing, Fresno IRS Campus at Fresno, California. The SP facility is composed of five (5) buildings totaling 540,000 square feet including a kitchen and credit union and a modern information technology services ( MITS) ADP area with over 10,000 square feet space. The building population consists of a fluctuating employee base of 5,000 temporary, seasonal, and/or permanent employees. RESPONSE REQUIREMENTS: All small businesses are hereby invited to submit a statement of capability. Statements of capability MUST identify two (2) or more contracts (INCLUDING CURRENT POINT OF CONTACT INFORMATION) in which the interested party served as the prime contractor providing 24/7 operation, maintenance, and repair services on similar size facilities with similar numbers of occupants and with similar sizes and complexity of equipment and systems. This would include central chilled water (chillers of 400 tons or larger) and low pressure boiler heating plant equipment (include capacity sizes of all equipment) in a campus environment including a single building of at least 250,000 square feet with a population of 1,500 or more and with a minimum of 40,000 square feet of mainframe ADP space. Statements must specifically address capabilities in operating, maintaining, and repairing central heating and cooling plant equipment and operations, maintenance and repairs to a rotary uninterruptible power supply (RUPS) system (in parallel operations with 3 units ranging up to 250 KVA each) and including RUPS battery maintenance and repairs, maintenance and repairs for emergency diesel-powered generators and automated transfer switches operating in a in parallel configuration, maintenance, repairs, and certification testing of medium voltage electrical systems, and maintenance and repairs to complex plumbing systems, and DIESEL-POWERED Fire pump and automatic controls. All capability statements should address the contractor’s ability to manage operations and operate building equipment, perform maintenance and repairs to an equivalent size facility with similar mechanical and electrical equipment as mentioned above. All equipment descriptions provided to show relevant experience shall be in detail depicting the equipment capacity, make, and function. Statements must also include a cover letter that includes the company name, address, telephone, facsimile, email address and business classification (small, small disadvantaged business, woman-owned small business, veteran-owned small business, service disabled veteran-owned small business, 8(a) and HUBZone). Interested parties shall respond with one hard copy of their capabilities statement. In addition to the hard copy, the capabilities statement shall be provided on a CD or DVD. The response shall be sent to the following address: Internal Revenue Service, Office of Business Operations, Attn: Denise Alvarez (OS:A:P:B:W:B), 1301 Clay Street, Suite 810S, Oakland, CA 94612-5217. Responses and questions must be submitted electronically via e-mail or facsimile by 3:00 PM, EST no later than January 2, 2010. Oral responses and inquiries will be treated as non-responsive. THE SUBMISSION OF THIS INFORMATION IS FOR PLANNING PURPOSES ONLY AND IS NOT TO BE CONSTRUED AS A COMMITMENT BY THE GOVERNMENT TO PROCURE ANY SERVICES, NOR DOES THE IRS INTEND TO AWARD A CONTRACT ON THE BASIS OF THIS REQUEST FOR INFORMATION OR OTHERWISE PAY FOR THE INFORMATION SOLICITED. Contracting Office Address: Internal Revenue Service Western Area Branch Office of Business Operations (OS:A:P:B:W) 1301 Clay Street Suite 810S Oakland, CA 94612-5217 Place of Performance: Internal Revenue Service Fresno Campus 5045 Butler Avenue Fresno, CA 93727
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/TREAS/IRS/IRSWPBAPFWR/TIRWR-10-FRESNO/listing.html)
- Place of Performance
- Address: Internal Revenue Service, Fresno Campus, 5045 Butler Avenue, Fresno, California, 93727, United States
- Zip Code: 93727
- Zip Code: 93727
- Record
- SN02021052-W 20091212/091210234845-ecb0531c1746315eb47a7408a86f71f0 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |