SOLICITATION NOTICE
30 -- Torquing Tools for the Pine Bluff Arsenal
- Notice Date
- 12/16/2009
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 423830
— Industrial Machinery and Equipment Merchant Wholesalers
- Contracting Office
- RDECOM Contracting Center - Pine Bluff (RDECOM-CC), ATTN: CCRD-PB, 10020 Kabrich Circle, Pine Bluff, AR 71602-9500
- ZIP Code
- 71602-9500
- Solicitation Number
- W911RP-10-T-0057
- Response Due
- 12/17/2009
- Archive Date
- 2/15/2010
- Point of Contact
- Elton Harrison, 870-540-4075
- E-Mail Address
-
RDECOM Contracting Center - Pine Bluff (RDECOM-CC)
(elton.harrison@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Solicitation W911RP-10-T-0057 is being issued as a (RFQ) and incorporates the provisions and clauses in effect through Federal Acquisition Circular 97-18. This Procurement is unrestricted, the NAICS code is 423830, the size standard is 100 employees. 52.212-2 EVALUATION--COMMERCIAL ITEMS (JAN 1999) a) The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers: Technical, Time of Delivery, Price : Technical is more important than, time of delivery, which is more important than price. (b) Options. The Government will evaluate offers for award purposes by adding the total price for all options to the total price for the basic requirement. The Government may determine that an offer is unacceptable if the option prices are significantly unbalanced. Evaluation of options shall not obligate the Government to exercise the option(s). (c) A written notice of award or acceptance of an offer, mailed or otherwise furnished to the successful offeror within the time for acceptance specified in the offer, shall result in a binding contract without further action by either party. Before the offer's specified expiration time, the Government may accept an offer (or part of an offer), whether or not there are negotiations after its receipt, unless a written notice of withdrawal is received before award.(End of clause) The Pine Bluff Arsenal requires quotes on the torque tools listed below: 1) Stanley DC Electric Lever angle tool Model EC12LA13-10 or equal. Side Voice Admitter 45 inch lbs, minus 3 inch lbs, plus 0 inch lbs. Front Voice Admitter 50 inch lbs, minus 5 inch lbs, plus 0 inch lbs. Speed 1375 rpm, max torque, 84 in lb. weight 1.7 lbs. Front and Rear Hi/low/OK lights for 360 degree viewing. Multi function switch for For/Rev and Parameter Select. Stanley Theta Control Model QC1001-X. Stanley High Flex 3m Whip Cable Model 20C107603. Unit price then total price. 2 ea. $ _________ $ __________ 2) Stanley DC Electric Lever straight Tool Moldel EC02LB-3 or equal. Internal Drink Tube Coupling, 10 inch lbs, minus 3 inch lbs, plus 0 inch lbs. Speed 1580 rpm, max torque 24 in lbs, weight 1.5 lbs. Front and Rear Hi/low/OK lights for 360 degree viewing. Multi-function switch for For/Rev and Paramenter Select. Stanley Theta Control Model QC1001-X, Stanley High Flex 3m Whip Cable Model 20C107603. Unit price then total price. 1 ea. $ _________ $ __________ The salient characteristics are listed as follows: 1. Tools must be torque controlled with strain gauge transducer. 2. Control algorithm must contain automatic downshift speed control. 3. Controller must be 100%programmable and self contained keypad without external device. 4. Controller must be 115 volts AC. 5. Controller must have at least 16 job setups and bolt counting functions. 6. Controller must have angle monitoring. 7. Controller must be able to store at least the last 25 rundowns. 8. Controller must have tool diagnostics from the front face. 9. Controller must have serial communications for data collection and error proofing. 10. Software must be imbedded in controller and site licensed for free upgrades. 11. Rundown must be viewable from display. 12. The package must include installation, operator training, and maintenance training. Acceptance shall be at destination upon delivery. Shipping terms will be FOB destination and will be delivered to Receiving Section RSI Branch, Bldg 53-990, Pine Bluff Arsenal, Pine Bluff, AR 71602-9500. The award will be a firm fixed price contract/purchase order and will be awarded using Simplified Acquisition Procedures. The following FAR/DFAR provisions and clauses apply to this acquisition: 52.211-6 (Brand Name or Equal), 52.212-1, 52.212-3, 52.212-4, 52.212-5, 252.212-7001. The following subparagraphs of FAR 52.212-5(b) apply: (6), (16), (18), (19), (20), (21), (22), (23), (25), (38), (40). The following subparagraphs of 52.212-5(c) apply: None. The following clauses of DFAR 52.212-7001 (b) and (c) apply: 252.225-7001 (Buy American Act Balance of Payment Program), 252.225-7014, 252.225-7016. A complete copy of FAR 52.212-3 must be included with the quote. The following clause also applies: DFARS 252.204-7004 Alt A, Central Contract Registration. Quote is due at 10 A.M. on December 17, 2009 and may be sent to issuing office via Fax, (870) 540-3730 (Attn: Elton Harrison)or E-mail, elton.harrison@us.army.mil
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/7770cf07de406df6beb48993da1eaac0)
- Place of Performance
- Address: RDECOM Contracting Center - Pine Bluff (RDECOM-CC) ATTN: CCRD-PB, 10020 Kabrich Circle Pine Bluff AR
- Zip Code: 71602-9500
- Zip Code: 71602-9500
- Record
- SN02025321-W 20091218/091216235641-7770cf07de406df6beb48993da1eaac0 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |