SOURCES SOUGHT
65 -- The Pacific Region Tri-Service Regional Business Office(TRBO) Region 12 announces a Request for Regional Incentive Agreement Quotation(RFRIAQ) for the standardization of Pulse Oximetry Sensors & Cables.
- Notice Date
- 12/16/2009
- Notice Type
- Sources Sought
- NAICS
- 423450
— Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers
- Contracting Office
- Pacific Regional Contr Ofc TAMC, ATTN: MCAA PC BLDG 160, 160 Krukowski Road, Honolulu, HI 96859-5000
- ZIP Code
- 96859-5000
- Solicitation Number
- W81K02-10-T-3106
- Response Due
- 1/6/2010
- Archive Date
- 3/7/2010
- Point of Contact
- Mary L. Summers, 8084333686
- E-Mail Address
-
Pacific Regional Contr Ofc TAMC
(mary.summers1@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- The Pacific Region Tri-Service Regional Business Office (TRBO) Region 12 announces a Request for Regional Incentive Agreement Quotation (RFRIAQ) for the standardization of Pulse Oximetry Sensors & Cables. The primary objective of this program is to standardize the quality of care across the regions based on the critical balance of clinical efficacy and value. It is intended for this initiative to result in the standardization of a clinically preferred product and source at the best possible price. It is also intended that standardized products be obtained through the Department of Defense Prime Vendor Program. As a clinically driven program, vendors and products must meet specific technical criteria plus products must meet or exceed specific clinical performance expectations as a primary consideration. Selection will be based clinical, technical, and pricing factors. The selection will be determined utilizing best value/trade-off criteria. The major Medical Treatment Facilities (MTFs) in the Pacific Region, TRBO Region 12 area include but are not limited to Tripler Army Medical Center, U.S. Naval Hospital Okinawa, U.S. Naval Hospital Guam, U.S. Naval Hospital Yokosuka, MEDDAC-K Seoul, 374th Medical Group Yokota Air Base, 18th Medical Group Kadena Air Base. This standardization action is part of the Medical/Surgical Prime Vendor program executed by the Defense Supply Center Philadelphia (DSCP), Directorate of Medical Materiel. In order to participate, your company must have a Distribution and Pricing Agreement (DAPA) and a separate commercial agreement with the Prime Vendors for the program, both Cardinal Health and Amerisource Bergen. This is pursuant to the DAPA clause by which DAPA holders agree to the standardization process and to allow Prime Vendors to distribute their products. This RFRIAQ is a supplement to the Prime Vendor Program and is not a contract. For additional information regarding DSCPs Prime vendor program please access their web site at https://dmmonline.dscp.dla.mil The resulting Regional Incentive Agreement (RIA) will be for a base period of two years (24 months) from date of selection with three one-year (12 months) option periods. Anticipated selection date is Mar 2010. Products and vendors that pass the technical criteria and pass the clinical performance expectations will be considered clinically preferred products and sources. Among these clinically preferred products and sources price will be the determining factor for this initiative. The selection of a single vendor is anticipated. However, if no single vendor can meet the total requirement of the Region, the Government reserves the right to make two or more selections for RIAs. In this event, selection would be based on a combination of MTF clinical preference and product availability. Point of Contact: Mary Summers, TRBO Technical Director 808-433-3686, mary.summers1@us.army.mil Cheryl Janus, RN, TRBO Clinical Analyst 808-433-7985, cheryl.janus@amedd.army.mil B. Products & Performance Required. The Pacific Region is seeking product line items in the category of Pulse Oximetry Sensors & Cables which at a minimum, includes the high volume lines below. Within this region, this product line has an estimated annual dollar requirement of $507,476. This forecast is based on historical prime vendor (both medical/surgical PV & pharmaceutical PV) sales during a recent 12-month period. The top 10 high volume usage lines for this project include: Part NumberItem DescriptionAnnual Cost (PV) MAXNSENSOR OXIMAX NEONATAL ADULT O2 $183,560.44 N25OXISENSOR II NEONATAL $100,350.22 MAX-NVG RPRO SRVC NELLCOR-MAX-N $77,941.28 MAXISENSOR OXIMAX INFANT 02 $39,484.20 I20OXISENSOR II INFANT DIGIT $26,111.64 MAXPSENSOR OXIMAX PEDIATRIC O2 $19,652.82 MAX-IVG RPRO SRVC NELLCOR-MAX-I $13,673.16 D20OXISENSOR II PED DIGIT $10,926.75 D25OXISENSOR ADULT DISP $8,221.25 DS100A-1SENSOR DURA-SENS AD FINGER CLIP $6,967.24 At the request of the Pacific Region MTFs, vendors will provide conversion information, prime vendor order numbers, and itemization of the brands, types, and packaging information of the products supplied by the vendor. C. Instructions to Vendors Vendors interested in participating in this standardization initiative should email their (1) Company name and address, (2) Point of Contact (POC) (Name and Phone Number, Fax Number, and E-mail address) to mary.summers1@us.army.mil and cheryl.janus@amedd.army.mil. and (3) Identification of the RFQRIA to which the vendor is responding. Submissions must be received by 5:00 post meridiem (p.m.) Hawaii Standard Time (HST) on the specified closing date/time of this solicitation. Vendors that fail to meet this submittal deadline will be disqualified from participating. In a one step notification process, the Pacific Region TRBO will request responses to the technical/company criteria, no charge literature, no charge sample sets, and best available pricing from each interested vendor. Vendors will have 30 calendar days to 1.) respond to the Pacific Region TRBO with their responses to the technical/company criteria and submission of best value price quotes; and 2.) deliver no charge literature and no charge sample sets to all participating MTFs. No charge literature and no charge samples must be received by the participating MTFs by close of business (COB) 5:00 PM HST, 30 days after the date of request to supply samples. All vendors must send the Pacific TRBO verification regarding the date of shipment. Vendor responses to the technical criteria must be in a prescribed electronic spreadsheet format that will be provided by the Pacific Region TRBO. Best value pricing must be in a prescribed electronic spreadsheet format, based upon the total requirements of the Pacific Region. Vendors that fail to respond to the technical criteria, fail to provide a price quote or fail to deliver the no charge literature and no charge sample sets within the time prescribed will be disqualified from further consideration. Vendor quotes should contain the vendor's best product matches for the products or product lines requested in this announcement. Vendor quotes should contain the vendor's best responses to all technical criteria listed in this announcement. Vendor quotes should contain the vendor's best tiered-pricing discounts off of the vendor's DAPA pricing based on committed volume of 80% of the total requirements of the MTFs in the Pacific Region. As this process will require vendors to submit certain information electronically, vendors are strongly encouraged to confirm with the Regional POC (stated above) that their electronic submissions have arrived at the Regional TRBO. Vendors are advised to confirm receipt, allowing adequate time for resubmission before the deadline, should a problem have occurred with the first submission. All e-mails must be digitally signed. The no charge samples to be provided are as follows: Pulse Oximetry Sensors & Cables: One (1) 18 Connector Cable with adapters for use with analyzer. One (1) 36 Connector Cable with adapters for use with analyzer. Five (5) Neonatal Adhesive Sensor use at ball of Neonates foot- less than 2 kg or greater than 42 kg Five (5) Infant Adhesive Sensor use around big toe 2-24 kg Five (5) Pediatric Adhesive Sensor use around finger digit 9-52 kg Five (5) Single Patient Use Adhesive Sensor Neonate use at ball of Neonate foot Five (5) Adult Adhesive Sensor Digit application Five (5) Adult Adhesive Sensor Nose application Five (5) Adult Clip Digit Sensors Five (5) Adult Clip Ear Lobe Sensors The no charge literature and no charge sample sets are required to be shipped to the following: Region Pacific TRBO Region 12 Tripler Army Medical Center ATTN: Mr. Rob Lumas, RN & George Fitzgerald TPRB Evaluation Samples Logistics Division, Materiel Branch Bldg 161 Krukowski Road Honolulu, Hawaii 96859-5000 (808) 433-5718 US Naval Hospital Okinawa Japan TPRB Evaluation Samples Attn: LT D. Salinas, NC, USN & LT S. Knisley, MSC, USN Bldg 6000, Camp Lester Chatan-Cho, Nakagami-Gun, Okinawa, Japan 904-0103 011-81-611-743-7815 US Naval Hospital Guam Farenholt Road Bldg 1, Room L103 Attn: Johnny Duenas & LCDR Hicks, NC, USN TPRB Evaluation Samples Agana Heights, Guam 96910 671-344-9671 35th Medical Support Squadron/SGSL Bldg 99 Attn: Capt Jennifer Franks & Mr. Paul Sayles TPRB Evaluation Samples FM 5205 Misawa AB, Japan 1-Chome, Hirahata, Misawa-Shi Aomori-Ken, Japan 033-0012 011-81-311-766-6008 US Naval Hospital Yokosuka Japan ATTN: Mr. Rockie Ramirez & CDR A. Acevedo, NC, USN TPRB Evaluation Samples Warehouse Bldg E-18 1-Chome, Honcho, Yokosuka, Kanagawa 238-0041 PO N68292 011-81-46-816-8592/7130 MEDDAC-K Attn: 1LT Paul Hwang & Maj E. Melville, AN Materiel Branch, Bldg 5119 South Post Yongsan Garrison Seoul, Korea, 140-012 011-82-010-3109-3692 18TH MDG Kadena 18th Medical Group/SGSL Attn: Megumi Uehara & Capt Dale Desalis, USAF, NC FM 5270 Bldg 626, Unit 5268, Davis Ave Kadena AB Okinawa City, Okinawa, Japan 904-0203 011-81-611-730-4175 The region intends to evaluate quotes and select a vendor or vendors, on initial submission/quote, without discussion. However, the Region reserves the right to conduct discussions and request revised quotes, if it is determined to be necessary. The Region reserves the right to reject all quotes and cancel the RFQRIA if it is determined to be in the governments best interest. Price will be analyzed based on the vendors anticipated Post Standardization Costs. Post standardization costs will be calculated for each vendor by applying the vendors offered prices to the anticipated annual usage of the region. Unmatched items will be represented in the Post Standardization Cost at the current suppliers non-discounted price. Among the products and sources that are determined to be clinically preferred, the best price (Post Standardization Cost) will be the deciding factor. D. Source Selection Procedures The Tri-Service Product Review Board (TPRB) for the Pacific Region is the governing bodies of the standardization process and program. This board includes clinicians and logisticians from the MTFs within the Pacific Region. The board is chaired by the Designated Senior Logistician (DSL). They are the deciding officials for this initiative. The Pacific Region TPRB is Co-Chaired by a physician from Naval Hospital Yokosuka and an Air Force Nurse Corps officer assigned to the Hawaii Multi-Service Marketing Management Office (MSMMO). The Region intends to evaluate quotes and select a vendor or vendor(s), without discussion. E. Technical Criteria Evaluations The vendors responses to the technical criteria will be reviewed for acceptability. Acceptability is defined as follows: 1) based on the vendors responses, the evaluators have reasonable confidence that the vendor can meet the standard of each technical criterion; 2.) based on the vendors responses, the evaluators have reasonable confidence that the line of products and/or services submitted meet the medical standards of care of the community that are applicable to such products or services; and 3) the information provided by the vendor is factually correct. Any misrepresentation of information will disqualify the vendor from further consideration. Failure to provide any requested information will disqualify the vendor from further consideration. Vendors must achieve an acceptable rating on their responses to the technical criteria for continued consideration in this initiative. Vendors who do not achieve an acceptable rating will be disqualified. F. Technical/Company Criteria The TPRB and CPTs consists of physicians, pharmacists, nurses, allied health professionals, and technicians from the Pacific Region MTFs. During the pre-source selection procedures, the TPRB and CPT validated/approved the equally weighted company/technical criteria outlined below. 1.Vendors must manufacture and/or distribute a complete product line of Pulse Oximetry Sensors & Cables. A complete line of product is defined as the MTFs requirements for usage items in the product line. Usage items are defined in the Medical Surgical Prime Vendor contract statement of work as DAPA items ordered at least once per month, and at least one unit per order. At a minimum, a complete product line includes the following products in the following sizes: 18 Connector Cable with adapters for use with analyzer. 36 Connector Cable with adapters for use with analyzer. Neonatal Adhesive Sensor use at ball of Neonates foot - less than 2 kg or greater than 42 kg Infant Adhesive Sensor use around big toe 2-24 kg Pediatric Adhesive Sensor use around finger digit 9-52 kg Single Patient Use Adhesive Sensor Neonate use at ball of Neonate foot Adult Adhesive Sensor Digit application Adult Adhesive Sensor Nose application Adult Clip Digit Sensors Adult Clip Ear Lobe Sensors 2. Vendors must have a DAPA or be in the process of applying for a DAPA number for Pulse Oximetry Sensors and Cables. Provide the DAPA number or proof of the application process with the initial submittal. This information is to be provided in response to the Technical/Company Criteria worksheet provided to the vendor. 3. Vendors must have an agreement with the Medical/Surgical Prime Vendor for the Pacific Region, Cardinal Healthcare. This information is to be provided in response to the Technical/Company Criteria worksheet provided to the vendor. 4. Vendors must submit discounts off DAPA for all products included in this standardization initiative. Vendors that fail to submit a discount from DAPA will be disqualified. Where lower uncommitted FSS prices are available, DAPA holders are required by previous agreement to provide the uncommitted FSS price as the DAPA price. Vendors shall not quote uncommitted FSS prices as the discounted price for purposes of this standardization initiative. 5. Vendors must provide latex free pulse oximetry sensors and cables. 6. Vendors must provide evidence of FDA 510 (k) approval for Pulse Oximetry Sensors and Cables. Class II Devices, Oximeter, 21 CFR 870.2700, product codes DQA and NLF and 21 CFR 870.2710, product code DPZ ear oximeter. Submit this information in response to the Technical /Company Criteria worksheet provided to the vendor. 7. Vendors must provide evidence of Medical Device User Fee and Modernization Act of 2002 (MDUFMA) P.L. 107-250510(k) approval for reprocessing 21 CFR 870.2700, product codes NLF reprocessed oximeter. Submit this information in response to the Technical/Company Criteria worksheet provided to the vendor. G. Clinical Performance Evaluation: In the pre-source selection procedures above, the TPRB and CPT members determined/approved that both product literature and sample sets are required for the evaluation in a clinical/pharmaceutical setting. Based on this determination, the following procedures apply. 1. The TRBO office will request no-cost, sample sets from the vendors to be delivered directly to participating MTFs, and the Pacific Region TRBO. Vendors will be given 30 calendar days to deliver the literature and samples for clinical evaluation and review. Literature and product samples must be shipped to arrive at the MTFs by COB, 5:00PM Hawaii Standard Time (HST), 30 calendar days after the notice to ship. Vendors who do not meet the deadline to deliver the literature and product samples by the deadline will be disqualified from this standardization initiative. 2. All vendors must send the Pacific Region TRBO verification regarding the shipment of literature and samples. This information will include the date of shipment and tracking numbers and the carrier used by the vendor. All literature and samples MUST be shipped via FedEx or UPS or DHL. 3. Vendor will provide, the following product samples for clinical/performance evaluation: (Unused samples will not be returned) One (1) 18 Connector Cable with adapters for use with analyzer. One (1) 36 Connector Cable with adapters for use with analyzer. Five (5) Neonatal Adhesive Sensor use at ball of Neonates foot - less than 2 kg or greater than 42 kg Five (5) Infant Adhesive Sensor use around big toe 2-24 kg Five (5) Pediatric Adhesive Sensor use around finger digit 9-52 kg Five (5) Single Patient Use Adhesive Sensor Neonate use at ball of Neonate foot Five (5) Adult Adhesive Sensor Digit application Five (5) Adult Adhesive Sensor Nose application Five (5) Adult Clip Digit Sensors Five (5) Adult Clip Ear Lobe Sensors 4. The CPT will evaluate each vendors literature and samples against the Clinical/performance criteria in a non-clinical/non-patient care setting. All clinical/performance criteria are weighted equally. The clinical evaluation period will last three weeks and take place in a clinical/pharmaceutical setting. The evaluation responses will be in a Likert type scale with a 1-5 scoring range. The scale descriptors are: One (1) = Strongly Disagree; Two (2) = Disagree; Three (3) = Neutral; Four (4) = Agree; and Five (5) = Strongly Agree. The CPT will send the completed evaluations to the TRBO for data entry and analysis and the results will be forwarded to the TPRB for review. Clinical/performance evaluations will be tabulated by the Pacific Region TRBO, and results will be forwarded to the Pacific Region TPRB members for final review. Clinical/Performance Criteria: 1. Edges and outer surfaces of adhesive sensors are smooth, no rough edges or surfaces, no areas of uneven distribution of material, any puckering, or bunching of seams and edges. (Inside of sensor is smooth, evenly woven materials, avoiding clumping, creasing or bunching of layers, which would put unequal compression on the patients skin) Addresses patient safety. 2. Adhesive sensor adheres to the skin but does not create any reddened skin response, no signs of inflammation, no signs of skin reactivity. (Skin reactivity to adhesive compromises the skin integrity and patient safety pain and inflammation disruption of skins line of defense for the body) Addresses patient safety. 3. All surfaces of the clip sensor are smooth both skin surface side and non-skin surface side. (No areas of poor distribution of materials rough, sharp edges which could cut, tear or disrupt skin integrity) Addresses patient safety and comfort. 4. The sensor cable fits into oxygen analyzer securely with no slippage of the sensor cable connector. (Connector must fit securely in order to provide a continuous pathway for oxygen saturation readings) Addresses patient safety.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/MEDCOM/DADA16/W81K02-10-T-3106/listing.html)
- Place of Performance
- Address: Pacific Regional Contr Ofc TAMC ATTN: MCAA PC BLDG 160, 160 Krukowski Road Honolulu HI
- Zip Code: 96859-5000
- Zip Code: 96859-5000
- Record
- SN02025339-W 20091218/091216235654-90b021567d50e8d860da6b4ebe29a238 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |