Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 19, 2009 FBO #2947
MODIFICATION

Y -- Design-Build F-22 Radar Cross Section Test Facility, Hill AFB, Utah

Notice Date
12/17/2009
 
Notice Type
Modification/Amendment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
US Army Engineer District, Sacramento, 1325 J. Street, Sacramento, CA 95814
 
ZIP Code
95814
 
Solicitation Number
W91238-09-R-0052
 
Response Due
2/11/2010
 
Archive Date
4/12/2010
 
Point of Contact
Charles S. Crivellaro, Phone: 916-557-5182, Gregory L. Tom, Phone: 9165577220
 
E-Mail Address
charles.s.crivellaro@usace.army.mil, Gregory.L.Tom@usace.army.mil
(charles.s.crivellaro@usace.army.mil, Gregory.L.Tom@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
NOTE: This solicitation is being re-listed for FY-10 under W91238-10-R-0016. The RFP and all plans & specifications will be available under W91238-10-R-0016. Please submit your proposal under W91238-10-R-0016. This acquisition is proceeding as a Full and Open Unrestricted Request for Proposal (RFP). Estimated Cost Range is between $ 10,000,000 and $ 25,000,000 Period of Performance for Design and Construction: 720 Days This Procurement will be conducted under FSC CODE: Y123, SIC CODE: 1541, NAICS Code: 236220. The size standard for this code is $33,500,000. All questions should be directed to the Contract Specialist, Connie Newell, e-mail Connie.L.Newell@usace.army.mil or FAX: No.: (916) 557-5278, or U.S. Army Corps of Engineers, Military Construction CECT-SPK, 1325 J Street, Sacramento, CA 95814-2922 JOB DESCRIPTION: Project will be a Design-Build (D-B) for a new High Bay Industrial Radar Cross Section Test facility (4,629 SM). Construction will be concrete foundation/floor slab, aircraft turntable/pit, structural steel frame with insulated wall/roof paneling system. Project includes aircraft vestibule, radar inspection bay, control room, restrooms, lightning protections fire protection/detection and IDS. Exterior includes necessary utility/infrastructure support, pavements, site improvements and comm. support. The project includes development of design deliverables for review (2 submittals plus back check processes), sustainable design using LEEDs rating system (Silver capable rating), anti-terrorism/force protection (will be met by compliance with the RFP requirements), design deliverables for grading, relocation/protection of utilities, site improvements, connections/runs, fire-protection/life safety, EMCS, HVAC, interior/exterior finishes, exterior lighting, parking, signage, and all necessary features (interior and exterior) to yield a safe, complete, and useable facility. The Contractor shall develop and complete the designs and construct the facilities. The Contractor will be given a buildable area boundary, for him to best locate/layout the proposed facility. The Design-Build Contractor may be required to perform any necessary geotechnical investigation yielding a geotechnical report that shall be used as a basis for design. Likewise, the D-B Contractor may be required to perform a topographical survey; also a basis for design. Following award, the contract will proceed as follows: This project will follow a normal completed design before construction begins process. All review comments for the work must be appropriately addressed and applicable construction techniques for unusual construction conditions must be properly defined and accepted and direction received from Contracting Officer prior to the start of construction. The RFP is anticipated to be posted on or about 21 December 2009. Proposals are due on or about 11 February 2010, 3:00 pm (Pacific). A SITE VISIT/PRE-PROPOSAL CONFERENCE IS: On/Or About 7 January 2010 @ 0900 Hours (Local Time), Bldg 366, Hill AFB, UT. Specific date, time and location will be identified in the solicitation. All PROPOSALS will be due on/or about 11 February 2010/3:00 pm Pacific. The specific date and time will be identified in the solicitation. OFFERORS ARE ADVISED THAT THIS PROJECT MAY BE DELAYED, CANCELED OR REVISED AT ANY TIME DURING THE SOLICITATION, SELECTION, EVALUATION, NEGOTIATION AND/OR FINAL AWARD PROCESS. ORDERING SOLICITATION: Plans and specifications will NOT be provided in hard paper copy or CD-ROM format. The solicitation and all amendments for this acquisition will be posted on a secure Government website known as FedBizOpps (www.fbo.gov) once the RFP is issued. Viewing/downloading documents from FedBizOpps will require prior registration in Central Contractor Registration (www.ccr.gov). If you are a first-time FedBizOpps user, you will also be required to register in FedBizOpps (www.fbo.gov) before accessing the RFP documents. To register, click on the Register Now button in the Vendors Block and follow the instructions. The following information will be required: Central Contractor Registration (CCR) Marketing Partner Identification Number (MPIN); DUNS Number or Cage Code; Telephone Number; and E-mail Address. Once registered with FedBizOpps, interested parties will then be able to log in and access the RFP documents. Important Note: Solicitation documents can be accessed ONLY via FedBizOpps. Please note that ALL contractors who want to register with FedBizOpps must be CCR registered, and have a MPIN, DUNS number or Cage code. For further information, please click on the FedBizOpps homepage link and the Vendor User Guide. The only PLAN-HOLDERS/BIDDERS LIST now available is via FedBizOpps. When viewing the Synopsis/Pre-solicitation Notice, you will click on the ADD ME TO INTERESTED VENDORS to enter your information. This function does not, however, allow you to identify yourself as a Prime or Sub. It is recommended that you identify your category in parentheses at either the beginning or end of your company name. For example: (Prime/Sub) XYZ Construction, or XYZ Construction (Prime/Sub). IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK FEDBIZOPPS FREQUENTLY FOR ANY AMENDMENTS OR CHANGES TO THE SOLICITATION.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA05/W91238-09-R-0052/listing.html)
 
Place of Performance
Address: US Air Force Bldg 366 Hill AFB UT
Zip Code: 84056
 
Record
SN02026038-W 20091219/091217234507-c80b132cd48e36d6eb75370cd9bf0690 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.