SPECIAL NOTICE
Z -- RECOVERY--Z--PROJECT NUMBER 39223, Carpentry, Elect, Plumbing, HVAC, repairs multiple bldgs.
- Notice Date
- 12/21/2009
- Notice Type
- Special Notice
- NAICS
- 238990
— All Other Specialty Trade Contractors
- Contracting Office
- Fort Hood DOC, Directorate of Contracting, 761st Tank Battalion Avenue, Room W103, Fort Hood, TX 76544-5025
- ZIP Code
- 76544-5025
- Solicitation Number
- W9115110C0032
- Archive Date
- 3/21/2010
- Point of Contact
- Jennifer Parker, 254 287-9801
- E-Mail Address
-
Fort Hood DOC
(jennifer.l.parker@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- RECOVERY PPS# 39223- Carpentry, elect, plumbing, HVAC, repairs multiple buildings. THIS NOTICE IS PROVIDED FOR INFORMATIONAL PURPOSES ONLY. THIS OPPORTUNITY IS ONLY AVAILABLE TO Leetex, LLC of Dallas, Texas, as a sole source 8(a) construction contract under the authority of FAR Part 19.8, and DFARS 219.800, the Partnership Agreement between the Small Business Administration and the Department of Defense. Perform complete asbestos abatement of building to include wall board, floor tile, black mastics, caulkings and putties. Perform demolition of wood framed walls; drywall ceilings; suspended acoustical ceiling grid and tiles; window air-conditioning units; vinyl composition floor tile and carpet; doors, vault door, windows, window blinds, wood cabinets, wood trim, wood paneling, wood wainscot paneling, wood counters, wood chair railings, wood book shelving, mechanical HVAC systems to include fan coil units, four pipe hot and cold water lines and ductwork; roof vents, electrical systems, ceiling fans, communication systems. Project will construct office areas, wall framing and drywall; replace flooring, replace windows and blinds; replace restrooms to include partitions, mirrors, ceramic wall and floor tile; replace complete suspended acoustical ceiling grid and tiles; replace windows and roller shades; replace doors and door frames; steam clean exterior brick walls; repair chips and holes in CMU block walls; fill, patch and fully restore the integrity of walls, ceilings and floors caused by demolition; fill, patch restore all substrates and finishes where fixtures, partitions and miscellaneous specialties have been removed; paint walls, doors, door frames, hand railings and exterior paintable surfaces; reseal exterior expansion joints; spray foam insulation inside wall framing at exterior walls and roof deck; replace windows, window frames, store front doors and store front windows; replace roof hatch and ladder; replace complete HVAC systems to include fan coil units and four pipe hot and chill water lines; replace complete plumbing systems to include drain piping, cold water piping, hot water piping, water closets, water closets, urinals, sinks; replace complete electrical systems to include electrical feeders, electrical panel boards, electrical metering, electrical conduit, boxes and electrical wiring; replace complete electrical lighting systems to include electrical luminaries, dimming luminaries, switches, electrical motion sensors, dimmer switches, conduit, boxes, electrical wiring; replace complete communications systems to include voice data/outlets, CAT 6 wiring, patch panels, conduit and boxes; replace complete fire alarm systems to include fire alarm panel, backup battery system, pull stations, visual devices, audible/visual devices, Knox box with tamper switch, Monaco fire reporting system and antenna. The magnitude of the project is anticipated to be $1,000,000.00 and $5,000,000.00, under NAICS 238990 ($14,000,000.00). The resulting contract will be a firm fixed price contract.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/db61c519e4d58c34768959314d2e286a)
- Record
- SN02028282-W 20091223/091221234017-db61c519e4d58c34768959314d2e286a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |