SOLICITATION NOTICE
59 -- This is a combined synopsis/solicitation for transformers and related items.
- Notice Date
- 2/19/2010
- Notice Type
- Combined Synopsis/Solicitation
- Contracting Office
- M67400 MARINE CORPS REGIONAL CONTRACTING OFFICE FAR EAST PSC 557 BOX 2000 FPO AP 96379-2000
- ZIP Code
- 96379-2000
- Solicitation Number
- M6740010T0034
- Response Due
- 3/1/2010
- Archive Date
- 3/16/2010
- Point of Contact
- Ms. Masuda 01181-98-970-8531 Masuda 011-81-6117-45-8531 Name:Masuda/Title:Contracting Specialist/Phone:011-81-6117-45-8531 (From U.S.)/098-970-8531 (within Japan) / email:yoko.masuda.ja@usmc.mil
- E-Mail Address
-
yoko.masuda.ja@usmc.mil
(yoko.masuda.ja@usmc.mil)
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis / solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a separate written solicitation will not be issued. This procurement is not a small business set-aside; any responsible source may submit an offer. Solicitation number M67400-10-T-0034 applies and is issued as a Request for Quotation. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-38 and Defense Notice Changed 20100120. The NAICS code is 335311. The agency need is for: The below is required standard for all transformers listed. THE FOLLING IS TO BE PROVIDED ALONG WITH THE TRANSFORMERS: 1. PCB CONTENT CERTIFICATION.2. OUTLINE DRAWING OF THE TRANSFORMER WITH DEVICES INDICATED. The below is the required standard for all transformers listed under this CLIN.1. COMPARTMENTS: A. THE HIGH AND LOW-VOLTAGE COMPARTMENTS SHALL BE SEPARATED BY STEEL ISOLATING BARRIERS EXTENDING THE FULL HEIGHT AND DEPTH OF THE COMPARTMENTS. B. COMPARTMENT DOORS: HINGED LIFT-OFF TYPE WITH STOP IN OPEN POSITION AND THREE-POINT LATCHING.2. HIGH VOLTAGE: A. 15 kV-200 A BUSHING WELLS. B. 15 kV-200 A LOADBREAK INSERTS (IEEE STD. 386). C. 15 kV-200 A OIL-IMMERSED LOADBREAK SWITCH. D. BAYONET TYPE, OIL-IMMERSED, EXPULSION FUSES IN SERIES WITH OIL-IMMERSED, PARTIAL-RANGE, CURRENT-LIMITING FUSES. COORDINATE TRANSFORMER PROTECTION WITH EXPULSION FUSE CLEARING LOW-CURRENT FAULTS AND CURRENT-LIMITING FUSE CLEARING HIGH-CURRENT FAULTS BEYOND THE INTERRUPTING RATING OF THE EXPULSION FUSE. E. PARKING STANDS. F. GROUND PAD. 3. LOW VOLTAGE: A. BUSHINGS WITH NEMA SPADE TERMINALS. B. ACCESSORIES: DRAIN VALVE WITH SAMPLER, FILL PLUG, PRESSURE RELIEF DEVICE, LIQUID LEVEL GAUGE, PRESSURE VACUUM GAUGE AND DIAL TYPE THERMOMETER WITH MAXIMUM TEMPERATURE INDICATOR. C. GROUND PAD. 4. A. LIQUID INSULATED, 60 Hz, 65 DEGREES C RISE, SELF-COOLED TYPE. B. TAP CHANGER SHALL BE EXTERNALLY OPERATED, WITH FOUR 2.5 PERCENT FULL CAPACITY TAPS, TWO ABOVE AND TWO BELOW RATED PRIMARY VOLTAGE. C. AUDIBLE SOUND LEVEL SHALL BE 51 DECIBELS OR LESS. D. TRANSFORMER SHALL INCLUDE LIFTING LUGS AND PROVISIONS FOR JACKING UNDER BASE. THE TRANSFORMER BASE CONSTRUCTION SHALL BE SUITABLE FOR USING ROLLERS OR SKIDDING IN ANY DIRECTION. PROVIDE TRANSFORMER TOP WITH AN ACCESS HANDHOLE. THE TRANSFORMER SHALL HAVE AN INSULATED LOW-VOLTAGE NEUTRAL BUSHING WITH NEMA SPADE TERMINAL, AND WITH REMOVABLE GROUND STRAP. 5. THE INSULATING LIQUID SHALL BE COMPOSED OF LOW FLAMMABLE MATERIALS AND AT A MINIMUM MEET NFPA70 AND FM P7825 STANDARDS, HAVING A FIRE POINT NOT LESS THAN 300 DEGREES C PER ASTM D 92 AND DIELECTRIC STRENGTH NOT LESS THAN 33 kV PER ASTM D 877. THE FLUID SHALL BE A BIODEGRADABLE INSULATING AND COOLING LIQUID, UL CLASSIFIED AND FM APPROVED AS "LESS-FLAMMABLE" FLUID, MEETING THE FOLLOWING PROPERTIES: A. POUR POINT: ASTM D 97, LESS THAN MINUS 15 DEGREES C. B. AQUATIC BIODEGRADATION: EPA 712-C-98-075, 100%. C. TROUT TOXICITY: OECD TEST 203, ZERO MORTALITY OF EPA 600/4-90/027F, PASS.6. PCB CONTENT: THE MANUFACTURER MUST CERTIFY THAT THE TRANSFORMER DOES NOT CONTAIN ANY PCB's. THERE IS TO BE NO DETECTABLE LEVEL OF PCB's AT A DETECTION LIMIT OF LESS THAN 0.1 (ZERO POINT ONE) ppm. 7. NAMEPLATE: IEEE C57.12.00 AND WITH "PCB CONTENT DATA (LESS THAN 0.1 ppm)" AND "MANUFACTURER'S NAME AND TYPE OF FLUID". 8. PAINT BASE, CABINET AND TANK MUNSELL 7GY3.29/1.5 GREEN. THE PAINT COATING SYSTEM SHALL COMPLY WITH NEMA C57.12.29. 9. ROUTINE AND OTHER TESTS (IEEE C57.12.00): COLD RESISTANCE MEASUREMENTS, PHASE RELATION, RATIO, NO-LOAD LOSSES AND EXCITATION CURRENT, LOAD LOSSES AND IMPEDANCE VOLTAGE, DIELECTRIC (IMPULSE, APPLIED VOLTAGE AND INDUCED VOLTAGE) AND LEAK. 10. FOB: Destination CLIN0001 TRANSFORMER-300 kVA 4EAPAD-MOUNTED; THREE-PHASE, NEMA C57.12.26 AND AS SPECIFIED HEREIN, LIQUID INSULATED, 300 kVA, 13,800 V DELTA PRI. (95 kV BIL), DEAD FRONT, RADIAL FEED, 208 Y/120 V SEC.-Brand Name or Equal CLIN0002 SWITCH 100EAFUSE CUTOUT; OVERHEAD POLE-TOP STYLE, ULTRA-HEAVY-DUTY, 27 kV, 125 kV BIL, 100 A, 12,000 AIC, PORCELAIN INSULATOR, WITH EXTENDED MTG. BRACKET & PARALLEL -GROOVE CONNECTORS. S&C ELECTRIC TYPE "XS" 89032R10-B-D Brand Name or Equal CLIN0003 ARRESTER 20EAELECTRICAL SURGE; ELBOW, METAL OXIDE VARISTOR, 15 kV CLASS, 15.3 kV MCOV (MAXIMUM CONTINUOUS OPERATING VOLTAGE), 1EEE 386 INTERFACE. MFR.: ELASTIMOLD, P/N: 167ESA-18 OR MFR.; COOPER POWER SYSTEMS, C/N: 3238018C18M Brand Name or Equal CLIN0004 ARRESTER 100EAELECTRICAL SURGE, CERAMIC, 15 KV, 2 TERMINAL, BRACKET MOUNT, 19"LG, MCGRAW-EDISON PN: AZS501B015 Brand Name or Equal CLIN0005 INSERT 20EAFEED -THRU, LOADBREAK; 200A-15 KV CLASS. MFR ELASTIMOLD, PN:1602A3R OR MFR COOPER POWER SYSTEMS, C/N:LFI215 Brand Name or Equal Ship to:Defense Logistics AgencyDefense Distribution CenterTracy Depot, Bldg 30, CCP25600 S. Chrisman Rd.Tracy, Ca. 95376 The Government intends to make single award to the responsible offeror whose offer is the most advantageous to the Government considering technical capability, price and delivery time.The following Provisions apply to this acquisition: FAR 52.211-6 Brand Name or Equal (Aug 1999)FAR 52.212-1 Instructions to Offerors-Commercial Items (Jun 2008)FAR 52.212-2 Evaluation-Commercial Items (Jan 1999) applies with paragraph (a) FAR 52.212-3 Offeror Representations and Certification Commercial Items (Jun 2008) FAR 52.212-4 Contract Terms and Conditions Commercial Items (Feb 2007)FAR 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders Commercial Items (Jun 2008)FAR 52.232-33 Payment by Electronic Funds Transfer (Oct 2003)FAR52.233-2 Service of Protests(Sept 2006)FAR52.247-34 F.O.B. Destination (Nov 1991)DFAR252.211-7003 Item Identification and Valuation (JUN 2005)DFAR252.212-7001 Contract Terms and Conditions (MAR 2008)Responsible offeror must be active in the Central Contractor registration on in accordance with DFARS 252.204-7004 (SEP 2007) DUNS, TIN, and CAGE Code must be written on submitted quote. Payment shall be made electronically by DFAS Yokota Japan if awarded to Japanese venders. If awarded to U.S. venders, WAWF clause will be added.Full text of these provisions can be accessed on-line at http://www.arnet.gove/far, http://farsite.hill.af.mil/vfdfara.htm. The following information must be provided with this quotation:Commercial and government entity code (Cage).Taxpayer identification number (Tin). Data universal numbering system (Duns). Estimated Delivery Date:GSA contract number if applicable Remit to Address Offers can be faxed to 011816117450969, emailed to Contracting Specialist Masuda: yoko.masuda.ja@usmc.mil, or mailed to the Regional Contracting Office, PSC 557 BOX 2000, FPO AP 96379-2000. Offers must be received no later than 1 MARCH 2010, 0800 LOCAL TIME(JAPANESE STANDARD TIME)
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/USMC/M67400/M6740010T0034/listing.html)
- Record
- SN02070559-W 20100221/100220000138-de8a2b89f528a90240abd47ce64f873a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |